Why Choose the ABB 2CDS381103R0105 Miniature Circuit Breaker?
The ABB 2CDS381103R0105, designated S301P-B10NA, is a premium 1P+N miniature circuit breaker (MCB) from the ABB System pro M compact S300P range. Designed for industrial and commercial electrical installations, it provides dependable protection against overloads and short circuits whilst simultaneously switching the neutral conductor for improved circuit isolation.
Combining thermal overload protection with rapid electromagnetic short-circuit tripping, the S301P-B10NA delivers reliable circuit protection whilst incorporating ABB features such as fail-safe terminals, an integrated trip indicator, contact position indication and a dual DIN rail release mechanism to simplify installation and maintenance.
With a 10 A rated current, a Type B tripping characteristic and a 25 kA rated short-circuit breaking capacity, this circuit breaker is particularly suited to protecting lighting circuits, heating systems, instrumentation, control equipment and other circuits with low inrush currents.
Key Advantages
- 1P+N configuration with protected phase and switched neutral.
- 10 A rated current for commercial and industrial installations.
- Type B tripping characteristic ideal for resistive and low-inrush loads.
- 25 kA short-circuit breaking capacity for high fault protection.
- Integrated trip indication assists with rapid fault diagnosis.
- Compatible with the ABB System pro M compact accessory range.
Key Features
- ABB System pro M compact S300P series.
- S301P-B10NA miniature circuit breaker.
- 1 protected pole with switched neutral (1P+N).
- 10 A rated current.
- Type B tripping characteristic.
- Thermal overload protection.
- Electromagnetic short-circuit protection.
- Top or bottom supply connection.
- 35 mm DIN rail mounting.
Reliable Protection for Low-Inrush Electrical Circuits
The ABB S301P-B10NA automatically disconnects circuits during overload and short-circuit conditions, protecting wiring, switchgear and connected equipment from electrical damage. Simultaneous neutral switching improves circuit isolation during maintenance and servicing.
Its Type B tripping characteristic is intended for circuits with relatively low starting currents, making it an excellent choice for lighting installations, electric heating, instrumentation, control systems and general-purpose distribution circuits where rapid fault protection is required.
Typical Applications
- Commercial lighting circuits.
- Electric heating systems.
- Industrial instrumentation.
- Control panels.
- PLC auxiliary circuits.
- Commercial distribution boards.
- OEM machinery.
- General low-inrush industrial installations.