SKU: 2CSF202001R3630Alt SKU: F202 AC-63/0.3MPN: 2CSF202001R3630
ABB f202ac-63/0.3 2 pole rcd 63a 300ma

ABB f202ac-63/0.3 2 pole rcd 63a 300ma

ABB F202 AC-63/0,3 2 pole Type AC residual current circuit breaker rated at 63 A with 300 mA residual current sensitivity for commercial and industrial electrical installations.

Price
List Price ex VAT
Your Price
On backorder Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

Trade pricing is personalised to your account

Available on backorder

£153.70

Why Choose the ABB F202 AC-63/0,3 Residual Current Circuit Breaker?

The ABB F202 AC-63/0,3 is a high performance residual current circuit breaker (RCCB) designed to provide reliable protection against earth leakage faults in commercial, industrial and building electrical installations. As part of the trusted ABB F200 series, it disconnects the electrical supply when dangerous residual currents are detected, helping to improve electrical safety and protect equipment.

This 2-pole Type AC RCCB is suitable for single-phase AC systems where protection against sinusoidal alternating residual currents is required. With a 63 A rated current and 300 mA residual operating current, it is ideal for feeder circuits, distribution boards and industrial installations requiring dependable earth fault protection.

Featuring a compact DIN rail mounted design, durable screw terminals and ABB's proven engineering, the F202 AC-63/0,3 offers straightforward installation together with long service life in demanding electrical environments.

Key Advantages

  • Reliable ABB F200 series RCCB.
  • 63 A rated current for higher load circuits.
  • 300 mA residual current sensitivity.
  • 2-pole Type AC earth leakage protection.
  • Compact DIN rail mounting.
  • Suitable for commercial and industrial electrical installations.

Key Features

  • ABB F202 AC-63/0,3 residual current circuit breaker.
  • F200 modular protection series.
  • 63 A rated current.
  • 300 mA rated residual current.
  • 2-pole construction.
  • Type AC residual current detection.
  • Instantaneous operating characteristic.
  • Screw terminal connections.
  • DIN rail mounting.

Reliable Earth Leakage Protection

Residual current circuit breakers continuously monitor the balance between live and neutral conductors. If an earth leakage fault is detected, the RCCB disconnects the supply rapidly to help reduce the risk of electric shock and minimise damage caused by insulation faults or earth leakage currents.

The ABB F202 AC-63/0,3 is intended for use alongside appropriately rated miniature circuit breakers or fuses, providing dependable residual current protection for modern electrical installations.

Typical Applications

  • Commercial electrical distribution boards.
  • Industrial switchboards.
  • Building services installations.
  • Machinery and equipment power distribution.
  • Control panels.
  • General single-phase AC distribution circuits.

Technical Specifications

Current 63 A
Manufacturer ABB
Series F200
Model F202 AC-63/0,3
Product ID 2CSF202001R3630
EAN 8012542780809
Product type Residual Current Circuit Breaker (RCCB)
Number of poles 2
Rated current 63 A
Rated residual current 300 mA
Residual current type Type AC
Rated operational voltage 230 / 400 V AC
Frequency 50 / 60 Hz
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Rated conditional short-circuit current 10 kA
Protection rating IP20 terminals / IP40 housing
Mounting type DIN rail
Operating temperature -25°C to +55°C
Dimensions (H × W × D) 85 × 35 × 69 mm
Weight approx. 0.20 kg
Standards IEC/EN 61008, UL 1053

Frequently Asked Questions

What is the ABB F202 AC-63/0,3 used for?

It provides residual current protection by disconnecting electrical circuits when earth leakage currents exceed 300 mA.

What current rating does this RCCB have?

The ABB F202 AC-63/0,3 has a rated current of 63 A.

What type of residual current does it detect?

This model is a Type AC RCCB designed to detect sinusoidal alternating residual currents.

Does this device provide overload protection?

No. An RCCB provides earth leakage protection only and should be installed together with a suitable circuit breaker or fuse.

Where is the ABB F202 AC-63/0,3 typically installed?

It is commonly installed on DIN rails within distribution boards, switchboards and industrial control panels.

Trusted by Electrical Professionals Worldwide

ABB F200 series RCCBs are trusted by electrical contractors, panel builders and industrial engineers for dependable earth leakage protection across commercial and industrial installations.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Tick  Priority sourcing and supply support

 Tick  Flexible payment terms for qualifying organisations

 Tick  Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution