Why Choose the Mersen AJT10 Amp-Trap 2000® Fuse?
The Mersen AJT10 is a premium Class J time-delay current-limiting fuse designed to provide superior protection for industrial and commercial electrical systems. Part of the renowned Amp-Trap 2000® AJT series, it combines excellent current limitation with a time-delay characteristic that accommodates motor starting currents and transformer inrush without nuisance operation, while delivering exceptional protection against overloads and short circuits.
The AJT10 is engineered using advanced material technology to provide IEC Type 2 "No Damage" protection for properly coordinated motor starters, helping reduce downtime and equipment replacement costs. Its compact Class J footprint requires only half the mounting space of many Class RK fuse installations, making it ideal where panel space is limited.
Rated at 10 A, 600 V AC and 400 V DC, the Mersen AJT10 is suitable for mains, feeders, branch circuits, motor circuits, transformers, control panels, lighting and heating applications requiring dependable time-delay protection.
Key Advantages
- Class J time-delay current-limiting fuse.
- 10 A current rating.
- 600 V AC and 400 V DC ratings.
- Time-delay characteristic prevents nuisance opening during motor starting and transformer energisation.
- 200 kA AC interrupting rating and 100 kA DC interrupting rating.
- Compact Class J dimensions require less mounting space than Class RK fuses.
- Provides IEC Type 2 "No Damage" protection when properly coordinated.
Key Features
- Mersen Amp-Trap 2000® AJT series.
- 10 A rated current.
- 600 V AC rating.
- 400 V DC rating.
- Time-delay dual-element design.
- Ferrule terminal construction.
- Extremely current-limiting performance.
- Fibreglass body for excellent dimensional stability.
- Compatible with Class J fuse holders.
Reliable Time-Delay Protection for Industrial Equipment
The Mersen AJT10 is specifically designed for circuits that experience temporary inrush currents, such as motors and transformers. Its time-delay characteristic allows normal starting currents to pass without nuisance fuse operation while still providing rapid current limitation during genuine fault conditions.
The Amp-Trap 2000® AJT range is widely specified for industrial control panels, motor control centres, feeders, branch circuits, bus duct systems and transformer protection where dependable overcurrent protection and high interrupting capacity are essential.
Typical Applications
- Motor circuits.
- Main and feeder protection.
- Branch circuits.
- Transformer protection.
- Industrial control panels.
- Bus duct systems.
- Load centres.
- Lighting and heating circuits.