Why Choose the Mersen ATQR1-4/10 Class CC Fuse?
The Mersen ATQR1-4/10 is a premium Class CC time-delay fuse designed to provide dependable overcurrent protection for industrial control transformers, solenoids, relays and other inductive loads. As part of the proven Mersen Amp-Trap® 2000 ATQR series, it delivers excellent current-limiting performance while withstanding the temporary inrush currents associated with transformer energisation and motor control circuits.
Its time-delay characteristic helps minimise nuisance fuse operation during normal equipment start-up while rapidly interrupting overloads and short circuits. The rejection-style Class CC construction also prevents incompatible fuse replacement when installed in a suitable Class CC fuse holder, improving electrical safety and system reliability.
With a rated current of 1.4 A, a maximum voltage rating of 600 V AC and a 300 V DC rating, the ATQR1-4/10 is ideally suited to industrial control panels, OEM machinery and automation systems requiring dependable branch circuit protection.
Key Advantages
- Compact Class CC time-delay fuse for industrial control applications.
- 1.4 A current rating for transformer and control circuit protection.
- 600 V AC and 300 V DC ratings for industrial electrical systems.
- Time-delay operation withstands transformer and inductive-load inrush currents.
- Current-limiting design helps reduce fault energy and equipment damage.
- Rejection-style construction helps prevent incorrect fuse replacement.
Key Features
- Mersen Amp-Trap® 2000 ATQR series.
- 1.4 A rated current.
- 600 V AC maximum voltage.
- 300 V DC maximum voltage.
- Class CC rejection-style fuse.
- Time-delay characteristic for inductive loads.
- High interrupting capacity for industrial fault protection.
- Compact ferrule design for space-saving installations.
Reliable Protection for Industrial Control Systems
The Mersen ATQR1-4/10 is specifically engineered to protect industrial control transformers and inductive equipment from overloads and short circuits. Its time-delay characteristic allows normal transformer magnetising current and equipment start-up surges to pass without unnecessary fuse operation while maintaining dependable protection against sustained faults.
Its advanced current-limiting design reduces the thermal and mechanical stress caused by high fault currents, helping protect sensitive electrical components, minimise downtime and improve the long-term reliability of industrial automation systems.
Typical Applications
- Industrial control transformers.
- Control panels and switchboards.
- OEM machinery.
- Motor control circuits.
- Relays, solenoids and contactors.
- Industrial automation equipment.