Why Choose the Mersen ATQR1-8/10 Class CC Fuse?
The Mersen ATQR1-8/10 is a premium Class CC time-delay fuse designed to provide dependable overcurrent protection for industrial control transformers, solenoids, relays and other inductive electrical loads. As part of the trusted Mersen Amp-Trap® 2000 ATQR series, it combines advanced current-limiting technology with the ability to withstand the high inrush currents commonly experienced during transformer energisation and equipment start-up.
Its time-delay operating characteristic helps eliminate nuisance fuse operation during normal energisation while rapidly interrupting overloads and short circuits. The rejection-style Class CC construction also helps prevent the installation of incorrect replacement fuses when used with compatible Class CC fuse holders, improving system safety and reliability.
With a rated current of 1.8 A, a maximum voltage rating of 600 V AC and a 300 V DC rating, the ATQR1-8/10 is ideally suited to industrial control panels, machinery and automation systems requiring dependable branch circuit protection.
Key Advantages
- Compact Class CC time-delay fuse for industrial control circuits.
- 1.8 A current rating for transformer and inductive load protection.
- 600 V AC and 300 V DC ratings for demanding industrial installations.
- Time-delay characteristic withstands transformer and equipment inrush currents.
- Current-limiting design reduces fault energy and equipment damage.
- Rejection-style construction helps prevent incorrect fuse replacement.
Key Features
- Mersen Amp-Trap® 2000 ATQR series.
- 1.8 A rated current.
- 600 V AC maximum voltage.
- 300 V DC maximum voltage.
- Class CC rejection-style ferrule fuse.
- Time-delay characteristic for inductive loads.
- High interrupting capacity of 200 kA AC.
- Compact 10 × 38 mm body for space-saving installations.
Reliable Protection for Industrial Control Systems
The Mersen ATQR1-8/10 is specifically engineered to protect industrial control transformers and inductive equipment from overloads and short circuits. Its time-delay characteristic allows temporary transformer magnetising current and equipment start-up surges to pass without unnecessary fuse operation while maintaining dependable protection against sustained faults.
Its advanced current-limiting design minimises the thermal and mechanical stresses created by high fault currents, helping protect valuable electrical equipment, reduce downtime and improve the reliability of industrial automation systems.
Typical Applications
- Industrial control transformers.
- Control panels and switchboards.
- OEM machinery.
- Motor control circuits.
- Relays, solenoids and contactors.
- Industrial automation equipment.