Why Choose the Mersen G1000115 High-Voltage Back-Up Fuse?
The Mersen G1000115, catalogue reference 45DB360V2P, is a high-voltage DIN back-up fuse-link designed to protect distribution transformers against the damaging effects of short-circuit currents. As part of the Mersen Limitor®-P series, it provides reliable transformer protection for medium-voltage switchgear, substations and power distribution systems.
Rated at 36 kV AC and 2 A, the G1000115 is manufactured using a ceramic fuse body with pure silver fuse elements and silver-plated copper end caps to deliver excellent electrical performance and long service life. It is manufactured in accordance with IEC 60282-1 and the VDE T4 specification for transformer protection fuse-links.
The fuse incorporates an integrated 80 N striker for operation indication and activation of compatible switchgear mechanisms. With a 31.5 kA breaking capacity, it rapidly interrupts severe fault currents before damage can occur to transformers and associated equipment.
Key Advantages
- High-voltage DIN back-up fuse for transformer protection.
- 36 kV AC rated voltage.
- 2 A rated current.
- 31.5 kA breaking capacity for dependable fault interruption.
- Integrated 80 N striker for indication and switchgear operation.
- Current-limiting design reduces thermal and mechanical fault energy.
- Ceramic construction with silver fuse elements for long service life.
- Suitable for medium-voltage switchgear and transformer installations.
Key Features
- Mersen Limitor®-P back-up fuse series.
- Manufacturer item number G1000115.
- Catalogue number 45DB360V2P.
- 36 kV AC IEC rated voltage.
- 2 A rated current.
- 31.5 kA maximum breaking capacity.
- 15 A minimum breaking current.
- Total clearing I²t of 0.6 kA²s.
- Power dissipation of approximately 9 W.
- Integrated 80 N striker.
- DIN clip-mounted construction.
- IEC 60282-1 compliant.
The Mersen G1000115 is engineered to interrupt high short-circuit currents before they can damage transformers and associated switchgear. Its current-limiting characteristics reduce thermal and mechanical stress, helping improve system reliability and minimise equipment downtime.
As a back-up fuse-link, the G1000115 should be coordinated with suitable overload protection. Correct selection should consider transformer rating, prospective fault current and switchgear manufacturer recommendations to ensure optimum protection.
Typical Applications
- Distribution transformer protection.
- Medium-voltage substations.
- Air-insulated switchgear.
- Gas-insulated switchgear.
- Industrial electrical distribution.
- Utility power networks.
- Renewable energy transformer installations.
- Medium-voltage feeder protection.