Why Choose the Mersen NH2GG50V500 NH Fuse Link?
The Mersen NH2GG50V500 is a high-performance DIN NH gG fuse link designed to provide dependable overload and short-circuit protection for low-voltage electrical distribution systems. Manufactured by Mersen, this NH Size 2 fuse link is suitable for protecting cables, conductors, switchgear and connected electrical equipment in demanding industrial and commercial installations.
Featuring a rated current of 500 A, a rated voltage of 500 V AC and a rated voltage of 250 V DC, the NH2GG50V500 delivers full-range gG protection. This allows the fuse to respond to sustained overload conditions as well as severe short-circuit faults, helping reduce equipment damage and unplanned downtime.
The fuse is manufactured in the standard NH Size 2 format and incorporates plain blade contacts, live gripping lugs and a double operation indicator. Its robust ceramic body, 120 kA AC breaking capacity and standardised dimensions make it suitable for compatible NH fuse bases and switch-disconnectors used in industrial power distribution systems.
Key Advantages
- Full-range gG protection against overloads and short circuits.
- 500 A rated current for high-current distribution applications.
- 500 V AC and 250 V DC voltage ratings.
- High 120 kA AC breaking capacity for dependable fault interruption.
- Double indicator provides convenient visual identification of fuse operation.
- Live gripping lugs support handling with an approved NH fuse replacement device.
- Standard NH2 construction suits compatible fuse bases and switch-disconnectors.
Key Features
- Mersen NH fuse-links gG 500 VAC series.
- NH Size 2.
- 500 A rated current.
- 500 V AC rated voltage.
- 250 V DC rated voltage.
- Full-range gG operating characteristic.
- 120 kA AC breaking capacity.
- Double fuse operation indicator.
- Live, non-isolated gripping lugs.
- Plain brass blade contacts.
- 52 mm body width.
- Durable ceramic insulating body.
Reliable Protection for High-Current Distribution Systems
The Mersen NH2GG50V500 protects electrical circuits by interrupting excessive current before it can cause serious thermal or mechanical damage. Its full-range gG operating characteristic enables the fuse to protect cables and electrical equipment against both prolonged overloads and high-energy short-circuit faults.
The fuse’s current-limiting performance and high breaking capacity help reduce the energy allowed to pass during a fault. When correctly selected and installed, it can improve electrical safety, protect valuable equipment and minimise disruption within industrial power distribution systems.
Typical Applications
- Industrial low-voltage switchboards.
- High-current electrical distribution panels.
- Cable and conductor protection.
- Transformer secondary circuits.
- Industrial machinery power supplies.
- Commercial and industrial electrical installations.