Why Choose the Mersen S081482 Medium Voltage Fuse?
The Mersen S081482, also identified as 55GD55V32P, is a robust medium voltage current-limiting fuse designed to protect transformers, switchgear and electrical distribution equipment against damaging overcurrent and short-circuit conditions. Manufactured by Mersen, it delivers dependable fault interruption for demanding industrial and utility power systems.
The S081482 uses current-limiting fuse technology to reduce the peak current and electrical energy passed into connected equipment during a fault. This helps minimise thermal and mechanical stress, supporting improved equipment protection and reducing the potential for extensive damage within medium voltage installations.
With a rated current of 32 A, a rated voltage of 5.5 kV AC and a substantial 55 × 259 mm cylindrical body, the Mersen S081482 is suitable for medium voltage distribution assemblies. Its integrated striker provides a mechanical indication when the fuse has operated and may support compatible trip or signalling mechanisms.
Key Advantages
- Dependable medium voltage current-limiting fuse protection.
- 32 A rated current for industrial distribution equipment.
- 5.5 kV AC voltage rating for medium voltage applications.
- Current-limiting operation helps reduce damaging fault energy.
- Integrated striker supports fuse operation indication.
- Robust construction for demanding industrial and utility environments.
Key Features
- Mersen medium voltage fuse technology.
- Manufacturer part number: S081482.
- Alternative reference: 55GD55V32P.
- Product designation: 559P CP GLD 55.259 32.
- Rated current: 32 A.
- Rated voltage: 5.5 kV AC.
- Fuse dimensions: 55 × 259 mm.
- Cylindrical construction with integrated striker.
Reliable Protection for Medium Voltage Equipment
Medium voltage fuses interrupt excessive fault currents before they can cause serious damage to transformers, switchgear, cables and associated electrical equipment. Their current-limiting characteristics reduce the peak fault current and let-through energy experienced by the protected circuit.
The Mersen S081482 combines a high voltage capability with robust construction and striker indication. It is suitable for installations where reliable protection, clear fuse status and effective fault energy limitation are essential for operational safety and continuity.
Typical Applications
- Medium voltage transformers.
- Industrial switchgear assemblies.
- Electrical distribution networks.
- Utility substations.
- Motor and feeder protection systems.
- Industrial power distribution equipment.