Why Choose the ABB S-ARC1 B6 Arc Fault Detection Device?
The ABB S-ARC1 B6 is a compact arc fault detection device (AFDD) with integrated miniature circuit breaker (MCB) designed to provide enhanced protection for single-phase final circuits. As part of the ABB S-ARC1 series, it combines arc fault detection with thermal-magnetic overload and short-circuit protection within a single two-module DIN rail device.
The S-ARC1 is designed to protect end-user circuits against earth, parallel and series arc faults as well as conventional overloads and short-circuit currents. Integrated AFDD indication and internal testing functionality assist with monitoring the device while providing an additional level of protection against electrical arcing that a conventional MCB alone is not designed to detect.
With a rated current of 6 A, a B tripping characteristic and a rated operational voltage of 230–240 V AC, the S-ARC1 B6 is designed for 1P+N single-phase circuits. It provides a 6 kA rated service short-circuit breaking capacity and a 7.5 kA rated ultimate short-circuit breaking capacity, making it suitable for compatible residential and commercial final circuits.
Key Advantages
- Combines arc fault detection and MCB protection in one compact device.
- 6 A rated current with B tripping characteristic.
- Protects against earth, parallel and series arc faults.
- Integrated thermal-magnetic protection against overloads and short circuits.
- 6 kA rated service short-circuit breaking capacity.
- 7.5 kA rated ultimate short-circuit breaking capacity.
- AFDD trip indication and internal test functionality assist with operation and diagnostics.
- Flexible mounting orientation and supply-side connection simplify installation.
- Compact two-module design helps conserve distribution board space.
Key Features
- ABB S-ARC1 arc fault detection device series.
- 6 A rated current.
- B tripping characteristic.
- 1P+N configuration with one protected pole.
- 230–240 V AC rated operational voltage.
- 50–60 Hz rated frequency.
- 170 V AC minimum operating voltage.
- 6 kA rated service short-circuit breaking capacity.
- 7.5 kA rated ultimate short-circuit breaking capacity.
- 500 V rated insulation voltage.
- 4 kV rated impulse withstand voltage.
- Integrated thermal-magnetic MCB functionality.
- 275 V AC overvoltage protection threshold.
- AFDD trip indication and internal test LED.
- Red ON / green OFF contact position indication.
- DIN rail mounting with screw terminals.
- Compact two-module construction.
Enhanced Arc Fault and Overcurrent Protection
Arc fault detection devices monitor electrical circuits for characteristic conditions associated with potentially dangerous electrical arcing. The ABB S-ARC1 is designed to protect against earth, parallel and series arc faults while its integrated miniature circuit breaker provides thermal-magnetic protection against overloads and short-circuit currents.
Combining AFDD and MCB functionality within a compact two-module device helps simplify distribution board design while providing protection against electrical faults that conventional MCBs alone are not designed to detect. The S-ARC1 series also incorporates AFDD indication and internal testing functionality to support dependable protection and straightforward fault diagnosis.
Typical Applications
- Residential electrical distribution boards.
- Commercial electrical distribution systems.
- Single-phase final circuits requiring enhanced arc fault protection.
- Circuits protected at 6 A requiring a B tripping characteristic.
- Lighting and compatible low-current final circuits.
- Installations where enhanced protection against electrically initiated fires is required.
- Installations requiring combined arc fault, overload and short-circuit protection.