Why Choose the ABB DS-ARC1 M C13 A30 Arc Fault Detection Device?
The ABB DS-ARC1 M C13 A30 is a compact arc fault detection device (AFDD) with integrated RCBO protection designed to provide comprehensive protection for single-phase electrical circuits. As part of the ABB DS-ARC1 M series, it combines arc fault detection, residual current protection, overload protection and short-circuit protection within a single three-module DIN rail device.
The DS-ARC1 M monitors electrical circuits for potentially dangerous arc faults while its integrated Type A RCBO provides protection against residual currents and overcurrents. The range also provides protection against overvoltage conditions, while LED indication, two dedicated test buttons and continuous internal self-testing help simplify verification and troubleshooting.
With a rated current of 13 A, a C tripping characteristic, 30 mA Type A residual current sensitivity and a rated operational voltage of up to 240 V AC, the DS-ARC1 M C13 A30 provides enhanced protection for 1P+N circuits. Its 10 kA breaking capacity and C-curve characteristic make it suitable for circuits that can experience moderate starting or inrush currents.
Key Advantages
- Combines AFDD and RCBO protection in one compact device.
- 13 A rated current with C tripping characteristic.
- 30 mA Type A residual current protection.
- Provides protection against arc faults, residual currents, overloads and short circuits.
- Provides protection against overvoltage conditions.
- 10 kA breaking capacity for installations requiring enhanced short-circuit protection.
- LED indication assists with electrical network troubleshooting.
- Separate test buttons verify AFDD and residual current protection functions.
- Continuous internal self-test supports dependable operation.
- Supply can be connected from either the top or bottom for installation flexibility.
Key Features
- ABB DS-ARC1 M arc fault detection device series.
- 13 A rated current.
- C tripping characteristic.
- 30 mA rated residual current.
- Type A residual current protection.
- 1P+N configuration.
- 10 kA breaking capacity.
- Integrated AFDD and RCBO functionality.
- LED indication for easier network troubleshooting.
- Two test buttons for AFDD and RCD function verification.
- Continuous internal self-test functionality.
- Top or bottom supply connection capability.
- Compatible with ABB System pro M compact busbars and accessories.
- DIN rail mounting with screw terminals.
Comprehensive Electrical Circuit Protection
Arc fault detection devices monitor electrical circuits for conditions associated with potentially dangerous electrical arcs. The ABB DS-ARC1 M combines AFDD functionality with Type A residual current and thermal-magnetic overcurrent protection, enabling one protective device to address arc faults, residual currents, overloads and short circuits.
The DS-ARC1 M range provides a 10 kA breaking capacity while retaining a compact three-module format. LED troubleshooting indication, separate AFDD and residual current test functions, continuous internal self-testing, flexible top or bottom supply connection and compatibility with ABB System pro M compact accessories help simplify installation and maintenance.
Typical Applications
- Residential electrical distribution boards.
- Commercial electrical distribution systems.
- Single-phase final circuits requiring enhanced arc fault protection.
- Circuits protected at 13 A requiring a C tripping characteristic.
- Circuits with moderate equipment starting or inrush currents.
- Installations requiring a 10 kA breaking capacity.
- Circuits requiring combined residual current and overcurrent protection.