Finder 1C.B1.9.005.0007POA is a complete BLISS2 smart heating and cooling control kit containing one battery-powered electronic thermostat with a 5 A volt-free changeover contact and one GATEWAY2 for 868 MHz wireless communication, programmable temperature schedules and remote management through the Finder YOU application.
£199.84
The Finder 1C.B1.9.005.0007POA is the complete BLISS2 smart thermostat kit: the BLISS2 programmable room thermostat packed together with Finder's second-generation GATEWAY2 (1Y.GU.005.1), accessories and technical documentation. It gives you everything needed for app control, Amazon Alexa and Google Assistant voice control in a single pack, with no separate gateway to source.
Part of the Finder Series 1C, BLISS2 combines accurate electronic room temperature regulation, weekly heating schedules, humidity display and an illuminated LED matrix interface with touch-sensitive controls. The included gateway links the thermostat to your 2.4 GHz Wi-Fi network, so temperatures and schedules can be checked and changed from anywhere using the Finder YOU app.
The thermostat runs on three AAA batteries with an estimated life of around 18 months, so no mains supply is needed at the thermostat position. Its volt-free 5 A, 250 V AC changeover contact provides a conventional on/off heating demand signal for compatible boilers, valves, pumps and other heating or cooling equipment.
What's in the pack: BLISS2 smart thermostat (1C.B1.9.005.0007) and second-generation GATEWAY2 (1Y.GU.005.1), plus accessories and technical documentation. If you already have a compatible second-generation gateway, the BLISS2 thermostat is also available on its own.
Because the kit includes GATEWAY2, BLISS2 can be connected to your home Wi-Fi as soon as it is installed. Using the Finder YOU app you can create weekly heating programmes, change the target temperature remotely and check the room temperature and humidity from your phone.
A typical schedule might raise the temperature before you get up, lower it while the property is empty, bring it back up before you return home and reduce it again overnight. Correctly configured schedules help avoid heating rooms when nobody needs them.
When you need a short-term change, the timed manual mode holds a different temperature for a set number of hours before returning automatically to the weekly programme. Permanent manual mode keeps a fixed temperature until it is cancelled in the app or on the thermostat.
Once the gateway is linked to Amazon Alexa or Google Assistant, commands such as "Alexa, set the living room to 21 degrees" change the target temperature without touching the thermostat or opening the app.
BLISS2 controls heating through a volt-free changeover relay (terminals 6 COM and 7 NO), rated 5 A at 250 V AC. It closes the contact when heat is called for and opens it when the room is up to temperature, which is how a conventional on/off room thermostat works. It therefore suits heating equipment with a standard on/off room thermostat connection, including many gas combi, system and regular boilers, zone valves and circulating pumps.
Finder states that BLISS2 can interface with traditional radiator, underfloor, heat pump and fan coil systems, and that it is a suitable replacement for most Finder or third-party room thermostats with equivalent on/off functionality.
Not suitable for modulating control: Finder documents BLISS2 with an on/off relay output only. It does not provide OpenTherm or manufacturer-specific bus control (such as boiler-brand digital thermostat connections). Boilers that rely on these for modulation will need to be wired to their standard on/off thermostat terminals instead, where the boiler provides them.
Before you buy, check your boiler manual for a conventional room thermostat or "switched live / volt-free" input, and confirm the load on the contact stays within 5 A at 250 V AC. Compatibility depends on the exact boiler model and its control terminals, not just the brand.
Where running a cable from the thermostat to the boiler or valve is difficult, the Finder 13.21.8.230.S000 radio actuator can switch the boiler, a zone valve or a fan coil wirelessly from BLISS2. Several actuators can be paired for multi-zone systems. Wiring to boilers and heating controls should be carried out by a competent installer with the circuits isolated.
| Brand | Finder |
|---|---|
| Product series | Series 1C |
| Product family | BLISS2 |
| Product type | Smart thermostat and gateway kit |
| Kit SKU | 1C.B1.9.005.0007POA |
| Manufacturer packaging code | 1C.B1.9.005.0007.POA |
| Package contents | 1 BLISS2 thermostat and 1 GATEWAY2 |
| Thermostat reference | 1C.B1.9.005.0007 |
| Gateway reference | 1Y.GU.005.1 |
| Thermostat technology | Electronic smart room thermostat |
| Primary application | Heating and cooling temperature control |
| Thermostat power supply | 3 × 1.5 V AAA alkaline batteries, LR03 |
| Optional power supply | Compatible external power supply accessory |
| Temperature adjustment range | +5 to +37 °C |
| Temperature display range | 0 to +50 °C |
| Temperature resolution | 0.1 °C |
| Temperature accuracy at +20 °C | ±0.5 °C |
| Adjustable temperature differential | 0.1–0.9 °C |
| Humidity sensor range | 1–99% RH |
| Output configuration | 1 changeover contact (SPDT) |
| Contact type | Volt-free |
| Contact rating | 5 A at 250 V AC |
| Thermostat-to-gateway communication | 868 MHz radio frequency |
| Gateway network connectivity | Wi-Fi |
| Wi-Fi frequency | 2.4 GHz |
| Gateway device capacity | Up to 10 BLISS2 thermostats |
| Smartphone application | Finder YOU |
| Programming | Daily and weekly schedules |
| Minimum scheduling interval | 15 minutes |
| Control modes | Manual, automatic and off |
| Climate functions | Heating and cooling control |
| Additional functions | Humidity display and frost protection |
| Voice assistant compatibility | Google Assistant and Amazon Alexa through supported integrations |
| Thermostat mounting | Wall mounting or compatible electrical wall box |
| Thermostat protection rating | IP20 |
| Thermostat dimensions | Approximately 124.2 × 83.5 × 17 mm |
| Installation environment | Indoor |
The pack contains the BLISS2 smart thermostat (1C.B1.9.005.0007) and the second-generation GATEWAY2 (1Y.GU.005.1), together with accessories and technical documentation. The gateway is what connects BLISS2 to Wi-Fi for app and voice control.
BLISS2 works with boilers and heating equipment that accept a conventional on/off room thermostat signal. Its volt-free relay is rated 5 A at 250 V AC. Many gas combi, system and regular boilers have this type of connection, but always check the exact boiler model's installation manual for its room thermostat terminals.
No. Finder documents BLISS2 with an on/off relay output only. It does not provide OpenTherm or brand-specific digital boiler communication, so it switches the boiler on and off rather than modulating its output.
It can, where the boiler has a standard on/off room thermostat connection, which many models from these manufacturers do. Compatibility depends on the specific model and its control terminals, not the brand, so check the boiler manual or ask your installer before buying.
Finder states BLISS2 can interface with radiator, underfloor, heat pump and fan coil systems through its on/off relay output, or wirelessly using the Finder 13.21.8.230.S000 radio actuator. The equipment must accept an on/off control signal within the contact rating.
Yes. With the included GATEWAY2 connected to your 2.4 GHz Wi-Fi and linked to your voice assistant account, you can change the target temperature using supported Alexa or Google Assistant commands.
A 2.4 GHz Wi-Fi network, an internet connection and the Finder YOU app on a compatible Android or iOS phone. The gateway is already included in this kit.
No. The thermostat runs on three 1.5 V AAA alkaline batteries, with an estimated life of around 18 months. The optional Finder 01C.02.8.230.0500 supply can be used instead, in which case the batteries must be removed. The gateway needs a 5 V DC supply of at least 1 A.
BLISS2 is only compatible with second-generation gateways (1Y.GU.005.1, or the 1Y.GW.8.230.BS00 modular gateway). If you already have one, the standalone BLISS2 thermostat (1C.B1.9.005.0007) may be the better choice.
Yes. Timed manual mode holds a different temperature for a set number of hours, from 1 hour upwards, then returns to the weekly programme automatically. Permanent manual mode holds a fixed temperature until cancelled.
Yes. Additional BLISS2 thermostats and Finder radio actuators can be added to the same gateway to build a multi-zone system.
Indoors on an internal wall, approximately 1.5 m above the floor, away from direct sunlight, radiators, draughts and doorways. It can be surface mounted or fitted over a "503" or 60 mm round wall box.
The Finder 1C.B1.9.005.0007POA BLISS2 kit pairs a stylish, battery-powered smart thermostat with Finder's second-generation gateway, giving you app control, weekly scheduling and Amazon Alexa and Google Assistant support from day one, on any heating system with a standard on/off room thermostat connection.
● Service Agreements
Credit Accounts
Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.








● frequently asked questions

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.
We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products.
Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.
Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.
Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.
Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.
● latest blog
LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.
2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...