Why Choose the Finder 48.P6.8.230.1060SPA 230 V AC 16 A Push-In Interface Relay Module?
The Finder 48.P6.8.230.1060SPA is a compact 16 A electromechanical interface relay module from the Finder Series 48 range, designed for industrial automation, electrical control panels and machinery control systems. Featuring a 230 V AC operating coil and a single changeover contact (SPDT), this DIN rail-mounted module provides a practical interface between control circuits and electrical loads.
A distinguishing feature of the 48.P6 configuration is its push-in terminal connection system. Unlike conventional screw-terminal interface relays, push-in technology enables efficient conductor installation and reduces the need for routine terminal tightening. Combined with a compact 15.8 mm module width, this makes the Finder 48.P6.8.230.1060SPA particularly suitable for densely populated control cabinets and installations requiring efficient assembly.
The module incorporates a plug-in electromechanical relay with silver-nickel (AgNi) contacts, providing dependable switching for appropriately rated industrial loads. Its 16 A contact rating, 250 V AC rated switching voltage and 4,000 VA resistive switching capacity make it suitable for applications ranging from building automation to industrial equipment control, subject to the manufacturer's wiring and load requirements.
Key Advantages
- 230 V AC nominal operating coil suitable for compatible mains-voltage industrial control circuits.
- 16 A changeover contact supports switching of appropriately rated electrical loads.
- Push-in terminal technology enables efficient, secure conductor connections without conventional screw tightening.
- Single changeover contact (1 CO / SPDT) provides normally open and normally closed switching functions.
- Compact 15.8 mm width helps conserve DIN rail space in control cabinets.
- 4,000 VA resistive switching capacity supports demanding AC1 switching applications.
- Silver-nickel contact material provides reliable performance for industrial switching duties.
- Plug-in relay construction allows convenient relay replacement during maintenance.
- DIN rail mounting supports organised installation within electrical control panels.
- Wide operating temperature range from -40 °C to +70 °C.
- Suitable for building automation, machinery control, electrical distribution panels and industrial interfaces.
Key Features
- Finder Series 48 interface relay module.
- Finder Type 48.P6 with push-in terminal connections.
- 230 V AC nominal coil voltage.
- 50/60 Hz AC coil operation.
- 1 CO / SPDT contact arrangement.
- 16 A rated contact current.
- 30 A maximum peak contact current.
- 250 V AC rated contact voltage.
- 400 V AC maximum switching voltage.
- 4,000 VA rated resistive switching capacity (AC1).
- 1,000 VA AC15 switching capacity at 230 V AC.
- Silver-nickel (AgNi) contact material.
- 0.55 kW single-phase motor rating at 230 V AC.
- Plug-in relay and socket assembly.
- Push-in wiring connections.
- DIN rail mounting.
- Monostable electromechanical operation.
- Compact industrial interface construction.
Important installation requirement: For contact currents above 10 A, the Finder Series 48 manufacturer documentation specifies parallel connection of the relevant contact terminals: 21 with 11, 24 with 14, and 22 with 12. Follow the applicable wiring diagram when using the module at its full 16 A contact rating.
Reliable Switching with Push-In Terminal Technology
The Finder 48.P6.8.230.1060SPA uses an electromagnetic relay controlled by a nominal 230 V AC supply. When the coil is energised, the internal contact mechanism transfers the common connection from the normally closed terminal to the normally open terminal. When the control supply is removed, the relay returns to its normal position.
The push-in terminal system is a major advantage for panel builders and maintenance engineers. It allows compatible conductors to be connected efficiently, helping reduce installation time and simplifying wiring within densely populated control cabinets. The module's plug-in relay construction also enables the relay to be replaced without disconnecting the socket's fixed wiring.
The 16 A contact system provides flexible switching for resistive and appropriately rated inductive loads. The Finder Series 48 contact specifications include a resistive AC1 capacity of 4,000 VA and an AC15 rating of 1,000 VA at 230 V AC. These ratings must be applied according to the load type, duty cycle and manufacturer's terminal wiring instructions.
For installations involving motors, solenoids or other inductive equipment, engineers should consider inrush current, contact protection, suitable overcurrent protection and the effect of switching transients. Correct installation and load selection help maintain reliable operation throughout the relay's service life.
Typical Applications
- Industrial automation and machinery control systems.
- Electrical control panels and DIN rail relay assemblies.
- 230 V AC control circuits.
- Building automation and building management systems.
- Industrial electrical distribution panels.
- PLC interface and auxiliary switching circuits.
- Heating, ventilation and air conditioning equipment.
- Motor starter auxiliary controls.
- Industrial hoists and crane control equipment.
- Equipment monitoring and signalling systems.
- OEM machinery and electrical equipment manufacturing.
- Industrial maintenance and relay replacement applications.