Why Choose the Finder 80.41.0.240.0000T Off-Delay Timer Relay?
The Finder 80.41.0.240.0000T is a professional multivoltage off-delay timer relay designed for industrial automation, railway applications and electrical control systems requiring accurate, adjustable delayed switching. Part of the Finder 80 Series, this compact modular timer provides a 0.1 s to 24 h adjustable timing range, a single changeover relay output and a dedicated control-signal input for initiating the off-delay function.
Featuring a universal 24–240 V AC/DC supply voltage, the Finder 80.41.0.240.0000T is suitable for integration into a wide variety of industrial control installations. Its off-delay with control signal operating function allows the output relay to remain energised for a selected period after the control signal is removed, making it particularly useful for delayed shutdown, ventilation overrun, sequential equipment stopping and controlled machinery operation.
The relay incorporates one single-pole double-throw (SPDT) changeover contact, providing both normally open and normally closed switching options. Its adjustable timing system offers six selectable time scales, allowing the required delay to be configured using accessible front-mounted adjustment controls.
Designed for demanding environments, the 80.41T variant is associated with railway-related requirements including EN 45545-2, EN 61373 and EN 50155. The timer features screw terminals, LED status indication, a compact 17.5 mm housing width and standard 35 mm DIN rail mounting, making it suitable for space-efficient installation inside industrial and railway electrical control cabinets.
Key Advantages
- Adjustable off-delay timing: Provides a selectable delay from 0.1 s to 24 h for a wide range of industrial control applications.
- Universal 24–240 V AC/DC supply: Simplifies integration into different control voltage systems.
- Control-signal operation: Initiates the off-delay sequence when the external control signal is removed.
- Six selectable time scales: Allows practical adjustment for short delays or extended operating periods.
- SPDT changeover output: Provides normally open and normally closed switching options.
- Dedicated mono-function design: Simplifies configuration where off-delay operation is required.
- Railway-oriented construction: Designed with reference to applicable railway fire, vibration, shock and environmental requirements.
- Compact 17.5 mm housing: Conserves space inside electrical control cabinets.
- 35 mm DIN rail mounting: Supports straightforward installation alongside industrial automation equipment.
- Screw-terminal connections: Provide secure and familiar wiring for panel builders and maintenance engineers.
- LED status indication: Supports convenient visual inspection during commissioning and fault-finding.
- Front-mounted timing adjustment: Enables convenient setting of the required delay without specialist programming equipment.
- Flat-blade and cross-head screwdriver compatibility: Simplifies adjustment and installation.
- High input/output isolation: Supports dependable separation between control and output circuits.
- Multivoltage electronic design: Incorporates Finder's PWM-based supply technology.
- IP20 protection: Suitable for installation within appropriately protected electrical enclosures.
- Wide industrial applicability: Suitable for delayed shutdown, control sequencing and auxiliary equipment operation.
Key Features
- Finder 80 Series modular electronic timer.
- Product family: 80.41T.
- Manufacturer part number: 80.41.0.240.0000T.
- Timer function: off-delay with control signal.
- Single-function timing operation.
- Adjustable timing range: 0.1 s to 24 h.
- Six selectable timing scales.
- Supply voltage: 24–240 V AC.
- DC supply voltage: 24–240 V DC.
- Output configuration: 1 SPDT changeover contact.
- One relay output with normally open and normally closed switching paths.
- External control-signal input.
- Electronic timing circuitry.
- LED status indication.
- Front-mounted timing controls.
- Adjustment using flat-blade or cross-head screwdrivers.
- High input/output isolation.
- Finder multivoltage PWM supply technology.
- Screw-terminal electrical connections.
- Standard 35 mm DIN rail mounting.
- Compact 17.5 mm housing width.
- IP20 ingress protection.
- Operating temperature range: −25 to +55 °C.
- Railway-related fire protection requirements: EN 45545-2.
- Railway vibration and shock requirements: EN 61373.
- Railway environmental requirements: EN 50155.
- DIN rail mounting standard: EN 60715.
- Suitable for industrial automation and railway electrical control applications.
Technical Specifications
- Manufacturer: Finder
- Series: 80 Series
- Product family: 80.41T
- Model: 80.41.0.240.0000T
- Manufacturer part number: 80.41.0.240.0000T
- Alternative reference: 804102400000T
- Product type: Modular electronic timer relay
- Timer category: Mono-function timer
- Operating function: Off-delay with control signal
- Timing initiation: External control-signal transition
- Number of timing functions: 1
- Timing range: 0.1 s to 24 h
- Number of time scales: 6
- Supply voltage, AC: 24–240 V AC
- Supply voltage, DC: 24–240 V DC
- Output contact configuration: 1 SPDT / 1 changeover
- Output technology: Electromechanical relay
- External control input: Yes
- Timing adjustment: Front-mounted selector and adjustment control
- Adjustment tool: Flat-blade or cross-head screwdriver
- Status indication: LED
- Terminal type: Screw terminals
- Number of connection terminals: 6
- Mounting: 35 mm DIN rail
- Housing width: 17.5 mm
- Ingress protection: IP20
- Operating temperature: −25 to +55 °C
- Railway fire protection standard: EN 45545-2 + A1:2016
- Railway vibration and shock standard: EN 61373
- Railway environmental standard: EN 50155
- DIN rail standard: EN 60715
- Typical application: Railway and industrial automation control
- EAN / GTIN-13: 8012823355108
Reliable Off-Delay Timing for Industrial and Railway Control Systems
Industrial machinery and railway electrical equipment frequently require controlled shutdown sequences rather than immediate disconnection of auxiliary equipment. Fans, pumps, ventilation systems and other electrical loads may need to continue operating for a predetermined period after a control command is removed. The Finder 80.41.0.240.0000T provides this functionality through its dedicated off-delay timing operation.
Unlike an on-delay timer, which delays output activation, the Finder 80.41T operates using an off-delay with control signal function. When the supply is present and the appropriate control signal is applied, the output responds according to the timer's operating logic. When the control signal is removed, the selected timing interval begins, and the relay output changes state after the programmed delay.
The adjustable timing range of 0.1 s to 24 h provides considerable flexibility. Short delays can be used for control sequencing, while longer periods are suitable for ventilation overrun, delayed equipment shutdown and auxiliary processes. Six selectable time scales allow the required delay to be configured without programming software.
The 24–240 V AC/DC universal supply makes the relay suitable for different industrial electrical control architectures. This flexibility can reduce the number of voltage-specific timer variants required across a maintenance inventory, while simplifying the selection of a replacement unit for compatible applications.
The timer provides a single SPDT changeover output, enabling a suitable electrical circuit to be switched using either the normally open or normally closed contact. The connected load must remain within the applicable output contact ratings, and inductive loads may require appropriate suppression or interface equipment.
The 80.41T variant is particularly relevant to railway electrical installations. Its design addresses requirements associated with fire behaviour of materials, mechanical vibration and shock, and railway environmental conditions. The specified operating temperature range of −25 to +55 °C supports operation in suitably protected industrial and transport control environments.
Installation is straightforward using the 35 mm DIN rail mounting system and screw terminals. The compact 17.5 mm housing minimises panel space requirements, while the front-mounted timing controls and LED indication support efficient commissioning, adjustment and maintenance.
Important operating consideration: The Finder 80.41.0.240.0000T is a control-signal-operated off-delay timer, not a true power-off-delay timer. Its timing function requires the appropriate supply conditions to be maintained. Applications requiring timing to continue after removal of the timer's own power supply should use a suitable true power-off-delay device, such as a compatible Finder 80.61T model.
Typical Applications
- Railway electrical systems: Delayed switching and auxiliary control functions in suitable railway installations.
- Industrial automation: Off-delay timing in automated machinery and process control systems.
- Ventilation overrun: Maintaining ventilation operation for a selected period after a control signal is removed.
- Fan control: Delayed shutdown of compatible extraction and cooling fans.
- Pump control: Timed stopping sequences for auxiliary pumping equipment.
- Conveyor systems: Delayed deactivation of selected conveyor control circuits.
- Machine shutdown sequencing: Maintaining auxiliary control outputs during controlled stopping procedures.
- Industrial process equipment: Timing functions for compatible process automation circuits.
- Electrical control panels: Compact DIN rail-mounted timing functions.
- Building automation: Delayed switching of suitable auxiliary equipment.
- Heating and cooling systems: Controlled overrun of compatible fans and circulation equipment.
- Lighting control: Delayed switch-off of suitable lighting circuits.
- Packaging machinery: Timed output control in automated production equipment.
- Material-handling installations: Delayed stopping of compatible auxiliary systems.
- Maintenance and refurbishment: Replacement of compatible Finder 80.41T timer relays.
- Transport infrastructure: Auxiliary timing applications requiring railway-oriented environmental characteristics.