83.91.0.240.0000T Finder timerAsymmetrical flasher DC 24/240V

83.91.0.240.0000T Finder timerAsymmetrical flasher DC 24/240V

Finder 83.91.0.240.0000T is a railway-specific multifunction electronic timer relay featuring a universal 24-240 V AC/DC supply, four asymmetric intermittent timing functions (LI, LE, PI, PE), an adjustable 0.05-second to 10-day timing range, one 16 A changeover contact, screw terminals and 22.5 mm DIN rail mounting.

SKU: 83.91.0.240.0000TAlt SKU: 839102400000TMPN: 83.91.0.240.0000T
Price
List Price £115.24 ex VAT
Your Price (ex VAT)
£115.24
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

SUBTOTAL (EX VAT) £115.24
Trade pricing is personalised to your account

Manufacturer Lead Time

£115.24

Finder 83.91.0.240.0000T Multifunction Timer Relay – 24–240 V AC/DC, 16 A, Railway Version, 4 Timing Functions

The Finder 83.91.0.240.0000T is a professional multifunction timer relay for railway and industrial automation applications. Part of the Finder 83 Series, this electronic timing relay provides precise, adjustable switching control for electrical circuits requiring repeated ON/OFF cycles, independently adjustable operating periods and reliable timed automation.

Featuring a 24–240 V AC/DC universal supply, a 16 A changeover contact and four selectable timing functions — LI, LE, PI and PE — the Finder 83.91.0.240.0000T offers a flexible solution for cyclic switching and asymmetric intermittent operation. Its adjustable timing range extends from 0.05 seconds to 10 days, making it suitable for both rapid repetitive operations and extended control sequences.

The T suffix identifies the railway-specific version, designed for applications involving vibration, mechanical shock and the environmental conditions associated with rolling stock. Its compact 22.5 mm-wide housing, screw terminal connections and standard 35 mm DIN rail mounting allow convenient integration into railway electrical cabinets, machinery panels and industrial automation systems.

Key Advantages

  • Universal 24–240 V AC/DC supply supports a wide range of industrial and railway control voltages.
  • Four selectable timing functions provide flexible cyclic and asymmetric intermittent switching.
  • Independent ON and OFF timing control enables different energised and de-energised periods.
  • 0.05 seconds to 10 days timing range accommodates short and extended switching cycles.
  • 16 A changeover contact provides versatile switching for suitable electrical loads.
  • Railway-specific T version is intended for demanding rolling stock applications.
  • 22.5 mm-wide housing helps conserve control cabinet space.
  • 35 mm DIN rail mounting simplifies installation alongside other electrical control components.
  • Screw terminals provide conventional, secure electrical connections.
  • IP20 protection rating for installation inside suitable electrical enclosures.
  • Electronic timing control reduces the need for additional external timing circuitry.
  • Selectable operating modes allow one device to perform several cyclic timing duties.
  • Suitable for railway equipment, industrial machinery, ventilation, pumps and automated switching systems.

Key Features

  • Finder 83 Series modular electronic timer.
  • 83.91 asymmetric intermittent timing configuration.
  • Railway-specific T variant.
  • 24–240 V AC/DC nominal supply range.
  • 50/60 Hz AC supply compatibility.
  • Four timing functions: LI, LE, PI and PE.
  • Asymmetric ON/OFF cycle control.
  • Adjustable timing from 0.05 s to 10 days.
  • One changeover output contact (1 CO / SPDT).
  • 16 A rated output contact.
  • Electromechanical relay output.
  • AgNi contact material.
  • Independent timing adjustment for the two phases of the operating cycle.
  • Compact 22.5 mm module width.
  • 35 mm DIN rail mounting.
  • Screw terminal connections.
  • IP20 enclosure protection rating.
  • Railway environmental design referencing EN 50155, EN 61373 and EN 45545-2.

Technical Specifications

  • Manufacturer: Finder
  • Product series: 83
  • Manufacturer part number: 83.91.0.240.0000T
  • Alternative part number: 839102400000T
  • Product type: Multifunction electronic timer relay
  • Timer category: Asymmetric intermittent / cyclic timer
  • Application version: Railway-specific T version
  • Nominal supply voltage: 24–240 V AC/DC
  • AC supply frequency: 50/60 Hz
  • Number of timing functions: 4
  • Available functions: LI, LE, PI, PE
  • Timing range: 0.05 s to 10 days
  • Maximum selectable timing: 864,000 s
  • Timing arrangement: Adjustable asymmetric ON/OFF cycles
  • Output type: Electromechanical relay
  • Contact configuration: 1 CO (SPDT)
  • Number of output contacts: 1 changeover
  • Rated output contact current: 16 A
  • Contact material: Silver nickel (AgNi)
  • Terminal type: Screw terminals
  • Mounting type: 35 mm DIN rail
  • DIN rail standard: EN 60715
  • Housing width: 22.5 mm
  • Housing height: Approximately 78.8 mm
  • Housing depth: Approximately 96 mm
  • Dimensions (W × H × D): Approximately 22.5 × 78.8 × 96 mm
  • Protection rating: IP20
  • Railway environmental reference: EN 50155, temperature class T1
  • Vibration and shock reference: EN 61373, Category 1 Class B
  • Railway fire protection reference: EN 45545-2
  • Country of origin: Italy
  • EAN / GTIN-13: 8012823429977
  • Typical applications: Railway rolling stock, industrial automation, cyclic control, ventilation and timed equipment switching

Four Selectable Timing Functions: LI, LE, PI and PE

The Finder 83.91.0.240.0000T provides four selectable functions for controlling repeated ON/OFF operations. The functions are designed for applications requiring adjustable cyclic timing, including sequences in which the relay remains energised for one period and de-energised for another.

LI – Asymmetric Flasher, ON First

The LI function provides repeated asymmetric switching with the output energised at the beginning of the cycle. The output remains energised for the selected ON period, then de-energises for the selected OFF period, repeating the sequence while the required supply and control conditions are maintained.

This function is useful where equipment must begin operating immediately and then alternate between active and inactive periods.

LE – Asymmetric Flasher, OFF First

The LE function provides repeated asymmetric switching with an initial OFF period. The relay waits for the selected delay before energising the output, then continues alternating between ON and OFF periods.

This mode is useful for applications requiring an initial waiting period before a repeated operating sequence begins.

PI – Asymmetric Pulse Timing

The PI function provides an asymmetric cyclic operating mode associated with pulse-initiated timing. It enables repeated switching sequences with independently adjustable timing periods, making it suitable for applications where the relationship between a control input and the switching cycle is important.

PE – Asymmetric Pause Timing

The PE function provides an asymmetric cyclic operating mode associated with pause-initiated timing. It is intended for control sequences requiring a defined initial pause and repeated timed switching.

Function selection note: The exact behaviour of LI, LE, PI and PE, including control-input triggering and reset conditions, should be checked against Finder's current 83.91 timing diagrams before commissioning. The function codes are not interchangeable.

How Asymmetric Intermittent Timing Works

An asymmetric timer relay allows the ON and OFF periods of a repeating cycle to be set independently. Unlike a symmetrical flasher, where both phases normally have the same duration, an asymmetric timer can keep a connected load energised for one period and de-energised for a different period.

For example, an industrial ventilation system may need to operate for a short interval before remaining inactive for a longer interval. Similarly, a cyclic lubrication system may require a brief operating period followed by an extended pause.

The Finder 83.91.0.240.0000T can perform this type of control through its selectable timing functions and adjustable time settings. Its single 16 A changeover contact allows a compatible load or control circuit to be switched according to the selected sequence.

The relay can therefore reduce the need for separate timing devices or complex external logic in straightforward cyclic control applications. Where a machine requires more advanced sequencing, feedback or safety-related monitoring, an appropriate PLC or control system may still be necessary.

Railway-Specific T Version for Rolling Stock Applications

The Finder 83.91.0.240.0000T is the railway-specific version of the Finder 83.91 multifunction timer. The T suffix identifies the variant intended for railway environments, where electrical equipment may be exposed to vibration, shock and changing operating conditions.

The railway version is associated with several important railway standards:

  • EN 50155: Electronic equipment used on railway rolling stock, including relevant environmental and electrical operating requirements.
  • EN 61373: Railway equipment testing for shock and vibration, with the railway variant referenced against Category 1 Class B.
  • EN 45545-2: Fire protection requirements relating to materials and components used in railway vehicles.

These characteristics make the Finder 83.91.0.240.0000T suitable for consideration in railway electrical control cabinets and rolling stock auxiliary systems. The complete installation must still be assessed against the relevant project specification and applicable railway requirements.

DIN Rail Installation and Electrical Integration

The Finder 83.91.0.240.0000T is designed for mounting on a standard 35 mm DIN rail in accordance with EN 60715. Its 22.5 mm-wide modular housing allows installation alongside relays, circuit protection devices, power supplies and other automation components.

The device features screw terminal connections for the supply and output circuits. The universal 24–240 V AC/DC supply simplifies integration into equipment using different control voltages, provided the supply remains within the manufacturer's specified operating limits.

The relay provides one changeover output contact, allowing suitable normally open or normally closed switching arrangements. The output contact rating must be assessed against the connected load, particularly where motors, solenoids or other inductive loads are involved.

The timer's IP20 protection rating means it should be installed inside a suitable electrical enclosure. Electrical installation and commissioning should be undertaken by competent personnel following the manufacturer's wiring diagrams and applicable safety standards.

Typical Applications

  • Railway rolling stock auxiliary control systems.
  • Railway electrical equipment cabinets.
  • Train ventilation and auxiliary equipment control.
  • Industrial cyclic switching systems.
  • Automated lubrication equipment.
  • Ventilation and extraction fan timing.
  • Industrial pumps requiring intermittent operation.
  • Conveyor and material-handling automation.
  • Packaging and processing machinery.
  • Industrial process sequencing.
  • Periodic equipment activation and deactivation.
  • Machinery requiring independently adjustable ON and OFF times.
  • Automated cleaning and flushing cycles.
  • Industrial control panels requiring a wide-range AC/DC timer.
  • Applications requiring a railway-specific 16 A multifunction timer relay.

Finder 83.91 Standard and Railway Timer Variants

The Finder 83.91 Series includes standard and railway-specific versions for asymmetric intermittent timing applications.

  • Finder 83.91.0.240.0000: Standard multifunction asymmetric timer with 24–240 V AC/DC supply, four timing functions, one 16 A changeover contact and 22.5 mm DIN rail housing.
  • Finder 83.91.0.240.0000T: Railway-specific version with the same core timing functionality and contact arrangement, intended for applications requiring the environmental characteristics associated with railway equipment.

When selecting a replacement, the exact manufacturer part number should be matched to the original equipment specification. The standard and railway variants should not be treated as interchangeable without confirming the relevant environmental and approval requirements.

Frequently Asked Questions

What is the Finder 83.91.0.240.0000T used for?

The Finder 83.91.0.240.0000T is a multifunction timer relay designed for railway and industrial automation applications requiring adjustable cyclic switching. It provides four timing functions and one 16 A changeover output.

What is the supply voltage of the Finder 83.91.0.240.0000T?

The timer operates from a 24–240 V AC/DC universal supply, making it suitable for compatible AC and DC industrial control systems.

What timing functions does the Finder 83.91.0.240.0000T provide?

The relay provides four selectable timing functions: LI, LE, PI and PE. These are asymmetric intermittent timing functions used for repeated ON/OFF control sequences.

What is the timing range of the Finder 83.91.0.240.0000T?

The adjustable timing range extends from 0.05 seconds to 10 days, allowing both short and extended timing intervals.

How many output contacts does the Finder 83.91.0.240.0000T have?

The timer features one changeover contact, also described as 1 CO or SPDT. The contact provides normally open and normally closed switching options.

What is the output contact current rating?

The Finder 83.91.0.240.0000T has a 16 A rated output contact. The permissible load depends on the switching category, electrical load characteristics and operating conditions.

What does the T suffix mean in Finder 83.91.0.240.0000T?

The T suffix identifies the railway-specific version, intended for applications involving the environmental requirements associated with railway rolling stock.

What is an asymmetric timer relay?

An asymmetric timer relay allows the ON and OFF periods of a repeating switching cycle to be adjusted independently. This is useful when equipment must operate for one period and remain inactive for a different period.

Can the Finder 83.91.0.240.0000T operate from a 24 V DC supply?

Yes. The timer supports a 24–240 V AC/DC supply range, so a compatible 24 V DC control supply can be used.

Can the Finder 83.91.0.240.0000T operate from a 230 V AC supply?

Yes. A 230 V AC supply falls within the timer's specified 24–240 V AC/DC operating range.

How is the Finder 83.91.0.240.0000T mounted?

The timer is designed for mounting on a standard 35 mm DIN rail and features a compact 22.5 mm-wide housing.

Does the Finder 83.91.0.240.0000T use screw terminals?

Yes. The timer uses screw terminal connections for integration into industrial electrical control panels.

What is the difference between Finder 83.91.0.240.0000 and 83.91.0.240.0000T?

Both models provide a 24–240 V AC/DC supply, four timing functions and one 16 A changeover contact. The 83.91.0.240.0000T is the railway-specific version, while the 83.91.0.240.0000 is the standard version.

Is the Finder 83.91.0.240.0000T suitable for railway applications?

Yes. The T version is intended for railway applications and is associated with railway environmental requirements including EN 50155, EN 61373 and EN 45545-2. Suitability for a specific project must be confirmed against the manufacturer's current documentation and the railway system specification.

Is the Finder 83.91.0.240.0000T a safety relay?

No. It is an electronic timing relay, not a standalone functional safety controller. It should not be relied upon as the sole protective device for an emergency-stop or other safety-critical function.

Designed for Railway Engineers and Industrial Automation Professionals

The Finder 83.91.0.240.0000T combines a universal 24–240 V AC/DC supply, four asymmetric timing functions, a 0.05-second to 10-day timing range and a 16 A changeover contact in a compact 22.5 mm DIN rail-mounted housing. Its railway-specific design makes it a practical choice for rolling stock electrical systems, industrial control panels and automated equipment requiring dependable, adjustable cyclic switching.

Product Information and Technical References

For complete wiring diagrams, timing charts, operating limits and railway compliance details, consult the current Finder 83 Series manufacturer documentation.

Additional product information is available from PLC-City – Finder 83.91.0.240.0000T and MEGE – Finder 83 Series Timers.

Engineering note: Verify timing diagrams, load ratings, environmental limits and railway approvals against the current manufacturer datasheet before final product selection or commissioning.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Priority sourcing and supply support

 Flexible payment terms for qualifying organisations

 Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...