Why Choose the Partex COL50-16/RA Right-Angle Copper Tube Terminal?
The Partex COL50-16/RA is a right-angle copper tube terminal designed to provide a secure electrical connection between a compatible 50 mm² conductor and an M16 stud or bolted terminal. Featuring an angled ring terminal configuration, this copper crimp lug offers a practical cable termination solution for industrial electrical installations, power distribution equipment, control panels and machinery where cable routing and connection orientation are important considerations.
As part of the Partex COL copper tube terminal range, the COL50-16/RA combines conductive copper construction with a tubular crimp barrel and a right-angle ring mounting connection. The tubular barrel accommodates the electrical conductor for crimp termination, while the angled mounting end allows the cable to approach the bolted connection from a different direction compared with a conventional straight ring terminal. This arrangement can help accommodate equipment layouts, cable entry requirements and restricted installation spaces.
Designed for 50 mm² nominal conductor cross-sections and M16 stud connections, the Partex COL50-16/RA is suitable for electrical assemblies requiring a crimped cable termination with an angled mounting arrangement. Supplied in a convenient pack of 50 terminals, it provides a practical solution for electricians, electrical panel builders, OEM equipment manufacturers and industrial maintenance engineers undertaking installation, production and cable termination projects.
Key Advantages
- Right-angle copper tube terminal provides an alternative to conventional straight cable lugs.
- 50 mm² nominal conductor size for compatible electrical cables.
- M16 stud connection enables attachment to suitable threaded connection points.
- Copper construction provides excellent electrical conductivity.
- Angled terminal configuration helps accommodate cable routing and connection orientation requirements.
- Closed ring design helps retain the terminal beneath compatible fastening hardware once correctly installed.
- Crimp termination supports secure mechanical retention and electrical continuity when correctly installed.
- Suitable for industrial electrical distribution equipment, control panels and machinery installations.
- Useful where cable entry direction or equipment layout makes a straight terminal less convenient.
- Supports organised cable connections in electrical cabinets, enclosures and equipment assemblies.
- Pack of 50 terminals provides a convenient quantity for panel manufacturing, installation and maintenance projects.
Key Features
- Partex COL copper tube terminal range.
- Right-angle ring terminal configuration for angled electrical connections.
- 50 mm² nominal conductor cross-section.
- M16 stud size for compatible bolted electrical connections.
- Conductive copper terminal construction.
- Closed ring mounting end for secure stud fastening.
- Tubular conductor entry designed for crimp termination.
- Designed for use with compatible electrical conductors and correctly selected crimping equipment.
- Practical for electrical cabinets and equipment with specific cable routing requirements.
- Suitable for industrial electrical assemblies, power distribution equipment and machinery wiring.
- Useful for OEM production, electrical installation and planned maintenance.
- Supplied in a pack containing 50 terminals.
Reliable Right-Angle Cable Termination for Industrial Power Distribution
Right-angle copper tube terminals are useful in electrical installations where equipment arrangement, available space or cable entry direction requires an alternative to a straight cable lug. The Partex COL50-16/RA provides a practical method of terminating a compatible 50 mm² conductor onto an M16 stud using an angled ring connection. This configuration can help accommodate cable positioning in electrical distribution equipment, industrial machinery, switchgear and control cabinets where the orientation of a bolted electrical connection is important.
Correct terminal selection and installation are essential for a dependable electrical connection. The conductor should be stripped to the appropriate length, inserted into the copper tube barrel and crimped using a tool and die suitable for the terminal and conductor combination. The ring connection should then be secured to the M16 stud using compatible fastening hardware and the equipment manufacturer's specified tightening torque. The terminal, conductor, stud, contact surface and fastening arrangement must all be verified for the intended electrical current and mechanical loading. Suitable electrical clearance, insulation, cable support, strain relief and bend radius must also be provided. The nominal conductor cross-section and stud size do not independently establish the current rating of the completed connection.
Typical Applications
- Industrial electrical power distribution assemblies.
- Electrical switchgear and control panel manufacturing.
- Busbar connection points incorporating compatible M16 studs.
- Motor control equipment and industrial machinery wiring.
- Electrical cabinets with restricted cable routing space.
- OEM electrical equipment manufacturing and assembly.
- Industrial automation and electrical distribution systems.
- Equipment installations requiring right-angle cable entry.
- Custom electrical cable assemblies using compatible 50 mm² conductors.
- Electrical maintenance and cable replacement projects.
- Bolted equipment connections where the terminal and contact arrangement have been verified as suitable.
- Electrical installations requiring a 50 mm² crimp barrel and M16 right-angle ring mounting connection.