Why Choose the ABB EPH-S16216 Protecta Home 16-Way 100A Dual RCD Consumer Unit?
The ABB EPH-S16216 (1TVC151800S3068) is a 16-way, 100 A main switch consumer unit with two 63 A residual current circuit breakers (RCCBs), designed for residential and light commercial electrical distribution. Part of the ABB Protecta Home range, this split-load consumer unit combines centralised supply isolation, residual current protection and flexible outgoing circuit distribution within a robust steel enclosure.
Featuring a 100 A main switch-disconnector and 2 × 63 A RCCBs, the EPH-S16216 allows outgoing circuits to be arranged into two separately protected groups. Its variable split-load arrangement offers installation flexibility, enabling electricians to allocate circuits between the RCCBs according to the approved assembly configuration and the electrical installation design.
With 16 outgoing ways and manufacturer-listed nominal dimensions of 250 × 450 × 105 mm (H × W × D), the ABB EPH-S16216 provides additional circuit capacity compared with smaller Protecta Home split-load models. It is an effective choice for installations requiring multiple protected circuits, practical maintenance access and dependable ABB electrical distribution equipment.
Key Advantages
- 16 outgoing ways provide generous capacity for residential and light commercial circuits.
- 100 A main switch-disconnector provides convenient centralised supply isolation.
- Two 63 A RCCBs provide residual current protection for separate circuit groups.
- Dual RCD split-load design supports organised distribution of outgoing circuits.
- Variable split arrangement offers flexibility when configuring the protected circuit groups.
- Steel enclosure construction provides a durable housing for electrical distribution equipment.
- Compact 250 × 450 × 105 mm nominal dimensions for a 16-way configuration.
- Suitable for use with appropriately selected modular outgoing circuit protection devices.
- Combines incoming isolation and two RCCB-protected circuit groups in one consumer unit.
- Part of the established ABB Protecta Home electrical distribution range.
- Suitable for new installations, consumer unit replacements and electrical refurbishment projects.
Key Features
- ABB Protecta Home consumer unit series.
- EPH-S16216 16-way dual RCD consumer unit.
- ABB order code 1TVC151800S3068.
- 16 outgoing circuit ways.
- 100 A main switch-disconnector for incoming supply isolation.
- 2 × 63 A RCCBs for residual current protection.
- Split-load circuit arrangement with two RCCB-protected groups.
- Variable RCCB split configuration within the approved Protecta Home assembly design.
- Durable steel consumer unit enclosure.
- Designed for compatible modular outgoing protective devices.
- Suitable for circuit arrangements incorporating appropriately selected MCBs.
- Nominal enclosure height: 250 mm.
- Nominal enclosure width: 450 mm.
- Nominal enclosure depth: 105 mm.
- Designed for residential and light commercial low-voltage electrical distribution.
- Part of ABB's professional electrical installation product portfolio.
Flexible Dual RCD Protection for 16-Way Split-Load Installations
The ABB EPH-S16216 combines a 100 A main switch with two 63 A RCCBs to provide incoming supply isolation and residual current protection for two groups of outgoing circuits. This split-load arrangement allows electricians to distribute circuits between separate RCCBs, rather than placing all circuits under one residual current protective device.
The variable split arrangement is an important feature of ABB Protecta Home RCCB split-load consumer units. It allows the distribution of outgoing ways between the two RCCB groups to be configured in accordance with ABB's approved assembly arrangements. With 16 outgoing ways, the EPH-S16216 offers additional flexibility for installations with multiple lighting, socket outlet and dedicated equipment circuits.
The 63 A rating of each RCCB is its rated current, not its residual operating current. RCCBs provide residual current protection but do not independently protect against overloads or short circuits. Appropriately selected outgoing overcurrent protective devices, suitable upstream protection and correct circuit allocation are therefore essential. Installation must comply with the applicable requirements of BS 7671 and the manufacturer's instructions.
Typical Applications
- Residential consumer unit installations in houses and apartments.
- New-build housing developments requiring multiple outgoing circuits.
- Domestic electrical distribution board replacements and upgrades.
- Property renovation and electrical refurbishment projects.
- Split-load electrical installations requiring two RCCB-protected circuit groups.
- Lighting, socket outlet and dedicated equipment circuits with suitable outgoing protection.
- Light commercial premises and small offices.
- Garages, workshops and ancillary building electrical distribution.
- Indoor electrical distribution systems requiring a 16-way consumer unit.
- Installations using compatible ABB modular circuit protection devices.