2CSG280815R1000 ABB CT1M-S-80 1000 Current Transformer 1000 A/5 A

2CSG280815R1000 ABB CT1M-S-80 1000 Current Transformer 1000 A/5 A

ABB CT1M-S-80 1000 2CSG280815R1000 is a 1000 A/5 A class 0.5 split-core through-primary current transformer with 10 VA class 0.5 output for accurate indirect electrical metering and monitoring applications.

SKU: 2CSG280815R1000Alt SKU: CT1M-S-80 1000MPN: 2CSG280815R1000
Price
List Price £356.21 ex VAT
Your Price (ex VAT)
£356.21
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

SUBTOTAL (EX VAT) £356.21
Trade pricing is personalised to your account

Manufacturer Lead Time

£356.21

Why Choose the ABB CT1M-S-80 1000 Current Transformer?

The ABB CT1M-S-80 1000, order code 2CSG280815R1000, is a 1000 A/5 A split-core current transformer designed for indirect measurement of electrical parameters in metering, monitoring and energy management applications. Part of ABB's Metering Accessories range, it transforms a nominal 1000 A primary current into a standardised 5 A secondary current for compatible electricity meters, network analysers and measuring instruments.

The ABB CT1M-S-80 series combines a through-primary measurement arrangement with split-core construction, allowing the transformer to be fitted around an existing busbar. This makes the range particularly useful for retrofit metering and monitoring installations where disconnecting or removing the primary conductor would be inconvenient.

With a 1000 A rated primary current, 5 A rated secondary current and accuracy class 0.5, the CT1M-S-80 1000 provides a 1000:5 transformation ratio for accurate indirect electrical measurement. It delivers 10 VA at class 0.5, 15 VA at class 1 and 20 VA at class 3, while its CT1M-S-80 aperture accommodates vertical busbars up to 85 × 55 mm.

Key Advantages

  • Split-core construction simplifies installation around existing busbars.
  • 1000 A/5 A current ratio for compatible metering and monitoring equipment.
  • Accuracy class 0.5 supports accurate current and energy measurement.
  • 10 VA rated output at class 0.5 for metering applications.
  • Large through-primary opening accommodates vertical busbars up to 85 × 55 mm.
  • FS 10 current limiting factor for metering applications.
  • Well suited to retrofit energy monitoring and existing electrical distribution installations.

Key Features

  • ABB CT1M-S-80 current transformer series.
  • Split-core through-primary construction.
  • 1000 A rated primary current.
  • 5 A rated secondary current.
  • 1000:5 current transformation ratio.
  • Accuracy class 0.5.
  • 10 VA rated output at class 0.5.
  • 15 VA rated output at class 1.
  • 20 VA rated output at class 3.
  • FS 10 current limiting factor.
  • 50–60 Hz rated frequency.
  • IP20 protection rating.
  • Designed for vertical busbar installations.

Practical Split-Core Measurement for Existing Electrical Installations

Current transformers allow meters and measuring instruments to monitor electrical circuits carrying currents above their direct measurement range. The transformer produces a proportional secondary current, allowing electrical parameters to be measured without routing the full primary circuit current through the connected measuring instrument.

The ABB CT1M-S-80 1000 combines this measurement principle with a split-core design, making it particularly useful for retrofit metering, maintenance and extensions to existing electrical systems. Its 1000 A/5 A ratio, class 0.5 accuracy and 85 × 55 mm vertical busbar opening provide a practical solution for high-current energy metering and monitoring applications.

Typical Applications

  • Electrical energy metering systems.
  • Commercial and industrial power distribution installations.
  • Main and sub-distribution switchboards.
  • Indirect measurement of circuits with a 1000 A nominal current.
  • Energy monitoring and management systems.
  • Current measurement with compatible network analysers, meters and instrumentation.
  • Retrofit current measurement on existing vertical busbars.
  • Industrial panel-building, maintenance and electrical instrumentation applications.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Busbar
Device Type Solid-core CT
Rated Primary Current (A) 1000 A
Secondary Current / Output 5 A
Accuracy Class Class 0.5
Rated Burden (VA) 10 VA
Product group Metering Accessories
Series CT1M-S-80
Order code / Product ID 2CSG280815R1000
Product type Split-core through-primary current transformer
Application Indirect electrical measurement and metering
Rated primary current 1000 A
Rated secondary current 5 A
Current ratio 1000:5
Best accuracy class 0.5
Rated output, class 0.5 10 VA
Rated output, class 1 15 VA
Rated output, class 3 20 VA
Current limiting factor FS 10
Rated frequency 50–60 Hz
Protection rating IP20
Construction Split-core, through-primary
Maximum vertical busbar section 85 × 55 mm
Mounting Busbar
Standard IEC 61869-2
Dimensions (H × W × D) 158 × 125 × 40 mm
Net weight 1.42 kg
EAN / GTIN 8012542808152
Pack unit 1 piece

Frequently Asked Questions

What is the ABB CT1M-S-80 1000 2CSG280815R1000 used for?

The CT1M-S-80 1000 is a split-core current transformer for indirect electrical measurement, converting a nominal 1000 A primary current into a standard 5 A secondary current for compatible meters, network analysers and measuring instruments.

What is the current ratio of the ABB CT1M-S-80 1000?

The CT1M-S-80 1000 has a 1000 A primary current and 5 A secondary current, providing a transformation ratio of 1000:5.

What is the accuracy class and rated output of the CT1M-S-80 1000?

The ABB CT1M-S-80 1000 has a best accuracy class of 0.5 and provides 10 VA at class 0.5, 15 VA at class 1 and 20 VA at class 3.

What busbar size can the ABB CT1M-S-80 1000 accommodate?

The CT1M-S-80 through-primary opening accommodates a vertical busbar up to 85 × 55 mm, making it suitable for substantial conductors in commercial and industrial distribution systems.

What is the advantage of the CT1M-S-80 split-core design?

The split-core construction allows the transformer to be installed around an existing busbar, making it particularly useful for retrofit metering, maintenance and energy monitoring installations where removing the primary conductor would be inconvenient.

Designed for ABB Electrical Metering and Retrofit Applications

ABB CT1M-S current transformers combine standard 5 A secondary measurement with split-core construction, providing a practical solution for accurate indirect current measurement in new and existing commercial and industrial electrical distribution systems.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Priority sourcing and supply support

 Flexible payment terms for qualifying organisations

 Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...