ABB 1STQ007967B0000 System Pro E Power XT6 Fixed 3/4-Pole Motor-Operated Interlocked Installation Kit – H400 W800 N2
The ABB 1STQ007967B0000 is a specialist Tmax XT6 circuit breaker installation kit designed for the ABB System Pro E Power modular low-voltage switchboard system. Identified by the manufacturer as KIT XT6 FISS.3/4P INT.M.OR.H400 L800 N2, this accessory is intended for compatible ABB Tmax XT6 3-pole and 4-pole fixed circuit breaker configurations incorporating a motor-operated interlocking arrangement.
The kit is specified for an installation configuration with a nominal height of 400 mm and a nominal width of 800 mm. The manufacturer's N2 designation identifies the intended two-position or two-device arrangement within the specified mounting configuration. The precise breaker positioning, interlocking arrangement and associated installation requirements should be verified against the relevant ABB assembly instructions.
As part of the ABB System Pro E Power product group, the 1STQ007967B0000 provides a dedicated mechanical installation solution for professional electrical distribution assemblies. It is suitable for switchboard manufacturers, industrial electrical contractors and panel builders who require a manufacturer-specific mounting kit for compatible Tmax XT6 fixed circuit breakers with motor-operated equipment.
Key Advantages
- Dedicated ABB Tmax XT6 circuit breaker installation kit.
- Designed for compatible 3-pole and 4-pole MCCB configurations.
- Specified for fixed circuit breaker installation.
- Supports the designated motor-operated interlocking arrangement.
- 400 mm nominal installation height.
- 800 mm nominal installation width.
- N2 configuration for the specified two-device arrangement.
- Integrates with the ABB System Pro E Power modular switchboard platform.
- Provides manufacturer-specific mechanical positioning for compatible XT6 equipment.
- Suitable for industrial and commercial low-voltage electrical distribution systems.
Key Features
- ABB manufacturer order code: 1STQ007967B0000.
- Product group: System Pro E Power.
- Manufacturer designation: KIT XT6 FISS.3/4P INT.M.OR.H400 L800 N2.
- Product type: Fixed circuit breaker installation kit.
- Compatible circuit breaker family: ABB Tmax XT6.
- Compatible pole configurations: 3-pole and 4-pole.
- Breaker installation version: Fixed.
- Operating configuration: Motor-operated.
- Interlocking configuration: Specified by the manufacturer's INT designation.
- Nominal installation height: 400 mm.
- Nominal installation width: 800 mm.
- Manufacturer arrangement designation: N2.
- Designed for compatible ABB System Pro E Power mounting structures.
- Mechanical installation accessory rather than a complete circuit breaker assembly.
Technical Specifications
- Manufacturer: ABB
- Product group: System Pro E Power
- Series: System Pro E Power
- Type / model: 1STQ007967B0000
- Manufacturer order code: 1STQ007967B0000
- Manufacturer description: KIT XT6 FISS.3/4P INT.M.OR.H400 L800 N2
- Product category: Switchboard circuit breaker installation accessories
- Product type: Fixed MCCB installation kit
- Compatible circuit breaker series: ABB Tmax XT6
- Compatible pole configurations: 3-pole / 4-pole
- Circuit breaker installation: Fixed
- Operating arrangement: Motor-operated configuration
- Interlocking arrangement: Manufacturer-designated INT configuration
- Nominal installation height: 400 mm
- Nominal installation width: 800 mm
- Configuration designation: N2
- Installation system: ABB System Pro E Power modular switchboards
- Primary function: Mechanical integration of compatible fixed Tmax XT6 circuit breakers in the specified motor-operated interlocked arrangement
- Component classification: Mechanical switchboard installation accessory
- Application: Low-voltage electrical distribution assemblies
Fixed Tmax XT6 Circuit Breaker Installation with Motor-Operated Interlocking
The ABB 1STQ007967B0000 installation kit is intended for the integration of compatible Tmax XT6 fixed moulded case circuit breakers within the System Pro E Power modular switchboard system. Its manufacturer designation identifies a specialised arrangement combining fixed circuit breaker installation, 3-pole or 4-pole compatibility, motor-operated equipment and an interlocking configuration.
A fixed circuit breaker installation differs from plug-in or withdrawable arrangements. In a fixed configuration, the circuit breaker is mechanically secured within the switchboard and connected according to the applicable manufacturer's instructions. Selecting the correct installation kit is important because the mounting geometry, connection clearances and associated accessories can vary between breaker versions.
The motor-operated configuration indicates that the intended circuit breaker arrangement accommodates the relevant motor-operated equipment. Motor operators may be used in electrical distribution systems requiring electrically initiated switching, remote operation or coordinated breaker control. However, the product designation does not establish that a motor operator, control unit or associated wiring accessories are supplied with the installation kit.
The manufacturer's INT designation identifies an interlocking configuration. Interlocking is used in appropriately designed switching systems to control the permitted operating states of associated circuit breakers. The exact interlocking method, operating sequence and required accessories must be established from ABB's documentation for the complete assembly.
The specified H400 L800 dimensions identify a nominal 400 mm high by 800 mm wide installation arrangement. These are configuration dimensions and should not be interpreted as the independently verified physical dimensions of the supplied kit. Compatibility depends on the complete System Pro E Power enclosure structure and the selected circuit breaker equipment.
The N2 designation identifies the intended arrangement within ABB's installation system. Although it is associated with a two-device configuration, it should not be treated as confirmation of the number of circuit breakers or motor operators included in the supplied product. The exact kit contents and mounting positions should be checked against the relevant ABB bill of materials and assembly instructions.
The 1STQ007967B0000 is specifically identified for ABB Tmax XT6 circuit breakers. It should not automatically be substituted for kits designed for Tmax XT3, XT4, XT5 or other frame sizes. Even within the XT6 family, compatibility with the selected breaker version, pole count, operating mechanism and interlocking equipment must be confirmed.
The ABB 1STQ007967B0000 is a mechanical installation accessory, not a complete circuit breaker or electrical protection device. It does not independently provide an electrical current rating, breaking capacity, overload protection or short-circuit protection. These characteristics depend on the selected circuit breakers and the completed switchboard assembly.
For professional switchboard builders, this dedicated ABB accessory supports consistent mechanical integration of the designated fixed, motor-operated and interlocked Tmax XT6 arrangement, helping ensure that the selected equipment is installed within the intended System Pro E Power configuration.
Typical Applications
- ABB System Pro E Power low-voltage distribution switchboards.
- ABB Tmax XT6 fixed circuit breaker installations.
- Compatible 3-pole and 4-pole MCCB mounting arrangements.
- Motor-operated circuit breaker installations.
- Interlocked circuit breaker arrangements where specified by ABB.
- Compatible H400 W800 switchboard installation configurations.
- Industrial electrical power distribution panels.
- Commercial building electrical distribution assemblies.
- Electrical distribution systems requiring coordinated breaker operation.
- OEM switchboard manufacturing and professional electrical panel building.