Why Choose the ABB OTP36A6M 45A 6-Pole Safety Switch?
The ABB OTP36A6M (1SCA022401R2620) is a robust 45 A, 6-pole enclosed safety switch-disconnector designed for manual switching and electrical isolation in industrial machinery, motor installations and low-voltage distribution systems. Part of the ABB OTP plastic enclosed switch range, it combines six main switching poles, a durable protective enclosure and a highly visible red and yellow operating handle.
With a 45 A AC-23A operational current rating at 380–415 V AC and a corresponding 22 kW motor switching rating, the OTP36A6M is suitable for appropriately rated industrial motor and inductive-load applications. Its six-pole construction provides additional switching flexibility compared with conventional three-pole isolators, allowing multiple conductors to be disconnected together through a single operating mechanism.
The OTP36A6M features a grey IP65 plastic enclosure, an IK08 impact resistance rating and a padlockable red and yellow pistol-grip handle. It is supplied with one normally open auxiliary contact, a fixed neutral terminal, protective earth terminals and top and bottom cable-entry knockouts. These features make it a practical enclosed switching solution for machine builders, electrical contractors, panel manufacturers and industrial maintenance engineers.
Key Advantages
- Six-pole switching configuration for applications requiring simultaneous disconnection of multiple conductors.
- 45 A AC-23A operational current rating at 380–415 V AC.
- 22 kW motor switching capability at 380–415 V AC under AC-23A conditions.
- 63 A AC-22A operational current rating at 380–415 V AC for suitable mixed resistive and inductive loads.
- 80 A conventional enclosed thermal current under the specified conditions.
- IP65-rated enclosure protects against dust ingress and water jets when correctly installed.
- IK08 impact resistance supports use in demanding industrial environments.
- Red and yellow pistol-grip handle provides clear, accessible ON/OFF operation.
- Padlockable operating handle supports controlled maintenance isolation procedures.
- Interlocked enclosure cover helps restrict normal access while the switch is ON.
- One normally open auxiliary contact included for compatible control and indication circuits.
- Fixed neutral and protective earth terminals support convenient electrical installation.
- Top and bottom cable-entry knockouts provide flexible wiring options.
- Complete enclosed assembly simplifies selection compared with separately specifying a switch, enclosure and operating handle.
Key Features
- ABB OTP36A6M plastic enclosed safety switch-disconnector.
- ABB manufacturer part number: 1SCA022401R2620.
- ABB order code: OTP36A6M.
- Number of main poles: 6.
- Rated operational current, AC-23A: 45 A at 380–415 V AC.
- Rated operational power, AC-23A: 22 kW at 380–415 V AC.
- Rated operational current, AC-22A: 63 A at 380–415 V AC.
- Conventional thermal current: 80 A, fully enclosed.
- Rated operational voltage: 750 V, main circuit.
- Rated insulation voltage: 750 V.
- Enclosure: Grey plastic.
- Operating handle: Red and yellow pistol grip.
- Operating positions: I–O / ON–OFF.
- Ingress protection: IP65.
- Impact resistance: IK08.
- Auxiliary contact supplied: 1 normally open (1 NO).
- Maximum auxiliary contact arrangement: 1 NO + 1 NC.
- Neutral connection: Fixed neutral terminal.
- Protective earth connections: Included.
- Cable-entry arrangement: Top and bottom knockouts.
- Enclosure dimensions: 200 × 145 × 90 mm.
- Applicable standards: IEC 60947-1 and IEC 60947-3.
Technical Specifications
- Manufacturer: ABB
- Product series: OTP Plastic Enclosed Switches
- Model: OTP36A6M
- Manufacturer part number: 1SCA022401R2620
- ABB order code: OTP36A6M
- ABB product group: 311004 – Plastic Enclosed Switches (OTP)
- Product type: Enclosed safety switch-disconnector
- Number of poles: 6
- Rated operational current AC-23A at 380–415 V: 45 A
- Rated operational current AC-23A at 500 V: 45 A
- Rated operational current AC-23A at 690 V: 20 A
- Rated operational current AC-22A at 380–415 V: 63 A
- Rated operational current AC-22A at 500 V: 63 A
- Rated operational current AC-22A at 690 V: 63 A
- Rated operational power AC-23A at 380–415 V: 22 kW
- Rated operational power AC-23A at 500 V: 22 kW
- Rated operational power AC-23A at 690 V: 15 kW
- Conventional thermal current, fully enclosed: 80 A
- Rated operational voltage, main circuit: 750 V
- Rated insulation voltage: 750 V
- Rated impulse withstand voltage: 1.5 kV
- Rated short-time withstand current: 1.5 kA for 1 s
- Rated short-circuit making capacity: 2.1 kA at 690 V AC
- Enclosure material: Plastic
- Enclosure colour: Grey
- Handle type: Pistol-grip rotary handle
- Handle colour: Red / yellow
- Handle padlocking: Yes
- Enclosure protection rating: IP65
- Housing impact resistance: IK08
- Auxiliary contacts included: 1 NO, 0 NC
- Maximum mounted auxiliary contacts: 1 NO + 1 NC
- Neutral terminal: Fixed neutral
- Protective earth terminals: Included
- Cover interlock: Included, with authorised defeat facility
- Main circuit terminal type: Screw clamp
- Main conductor connection capacity: 1.5–35 mm²
- Main terminal tightening torque: 2 N·m
- Wire stripping length: 13 mm
- Cable-entry position: Top and/or bottom
- Cable-entry knockouts: 2 × M32 + M16 per side
- Enclosure height: 200 mm
- Enclosure width: 145 mm
- Enclosure depth: 90 mm
- Dimensions (H × W × D): 200 × 145 × 90 mm
- Pollution degree: 3
- Standards: IEC 60947-1, IEC 60947-3
- Country of origin: Finland
- EAN: 6417019131115
Six-Pole Electrical Isolation for Industrial Machinery and Motor Circuits
The ABB OTP36A6M is designed to provide dependable manual switching and isolation where an installation requires more than the three main switching poles found on conventional three-phase isolators. Its six-pole construction enables multiple conductors to be switched together using one operating mechanism, making it suitable for appropriately engineered multi-conductor isolation arrangements.
For industrial motor applications, the OTP36A6M provides a 45 A AC-23A operational current rating at 380–415 V AC, corresponding to a 22 kW motor switching rating. AC-23A is a utilisation category associated with switching motor loads and other highly inductive loads. The correct device rating must always be selected according to the operating voltage, connected load and applicable switching duty.
The red and yellow pistol-grip handle provides a clearly visible manual control point on the front of the enclosure. Its padlocking capability supports maintenance isolation and lockout arrangements, while the interlocked cover helps restrict normal access to the internal switching equipment when the handle is in the ON position. The cover interlock can be defeated for authorised access where permitted by the manufacturer's instructions and relevant safety procedures.
The OTP36A6M is housed in a grey plastic enclosure rated IP65, offering protection against dust and water jets when correctly installed. The IK08 impact resistance rating provides additional durability for industrial settings. Knockout openings at the top and bottom allow cable entries to be configured for the installation, with suitable cable glands required to maintain the intended enclosure protection.
For control and indication purposes, the unit includes one normally open auxiliary contact. This can be used with a compatible electrical control or monitoring circuit, for example to provide switch-position signalling. The assembly also incorporates a fixed neutral terminal and protective earth terminals, although the neutral terminal is not an additional switched pole.
The OTP36A6M is a manual switch-disconnector, not an automatic circuit breaker or motor overload relay. It does not independently provide automatic overload or short-circuit tripping. The complete installation must include appropriately selected circuit protection, conductor sizing and safe isolation procedures.
Typical Applications
- Six-pole electrical isolation: Disconnecting multiple conductors through a single mechanical switching arrangement.
- Industrial motor installations: Providing local isolation for suitably rated motor circuits.
- Machinery main switches: Serving as an enclosed manual supply switch for compatible industrial equipment.
- Manufacturing plants: Supporting local electrical isolation of production machinery.
- Maintenance isolation: Enabling controlled disconnection before servicing electrical equipment.
- Multi-conductor switching: Supporting electrical systems requiring more than three simultaneously operated switching poles.
- Industrial control systems: Providing a local switch-disconnector with auxiliary contact indication.
- Conveyor installations: Isolating suitable motor-driven material handling equipment.
- Pumping and ventilation systems: Providing manual isolation for compatible motor supplies.
- OEM machinery: Integrating a complete six-pole enclosed safety switch into industrial equipment.
- Electrical distribution: Providing local disconnection of appropriately rated low-voltage circuits.
- Industrial maintenance and upgrades: Replacing compatible enclosed switch-disconnectors where electrical and mechanical specifications match.