ETE DV400P6S6 Dual Input Voltage Control Transformer 400VA 0/240/415V to 0/24V

ETE DV400P6S6 Dual Input Voltage Control Transformer 400VA 0/240/415V to 0/24V

ETE DV400P6S6 is a 400 VA single-phase dual-input-voltage industrial control transformer with selectable 240 V AC or 415 V AC primary connections, a nominal 24 V AC secondary output, Class E insulation, 8% voltage regulation, dimensions of 120 x 108 x 120 mm, weight of 5.5 kg and EPH 3 or EPN 2 enclosure references.

SKU: DV400P6S6MPN: DV400P6S6
Price
List Price £86.70 ex VAT
Your Price (ex VAT)
£86.70
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

SUBTOTAL (EX VAT) £86.70
Trade pricing is personalised to your account

Manufacturer Lead Time

£86.70

Why Choose the ETE DV400P6S6 400 VA Dual-Input Control Transformer?

The ETE DV400P6S6 is a versatile 400 VA single-phase industrial control transformer designed to convert either a 240 V AC or 415 V AC primary supply into a nominal 24 V AC secondary output. Manufactured by Eastern Transformers & Equipment (ETE), this model forms part of the established ETE DV dual-input-voltage stock control transformer range, developed for electrical panel builders, OEM machinery manufacturers and industrial automation applications requiring a dependable low-voltage AC control supply.

Featuring a 0/240/415 V primary terminal arrangement, the DV400P6S6 allows installers to select the correct primary connection for the available supply voltage. Its 0/24 V secondary terminals provide a nominal 24 V AC output for compatible contactors, relays, control devices and auxiliary electrical equipment. This dual-input design offers flexibility for industrial machinery and control panels intended for different electrical supply configurations.

With a substantial 400 VA apparent power rating, Class E insulation and 8% voltage regulation, the ETE DV400P6S6 provides a practical solution for control systems requiring a dedicated 24 V AC supply. The DV transformer range incorporates continuous-duty construction, IP20 touch-proof terminals, Class H varnish impregnation and a core earth connection for industrial electrical installations.

The DV400P6S6 measures 120 × 108 × 120 mm and weighs 5.5 kg. Its specified EPH 3 or EPN 2 enclosure references provide options for suitably enclosed installations, making this transformer a practical choice for machinery panels, electrical control cabinets and industrial automation systems.

Key Advantages

  • Dual-input-voltage flexibility: Supports either a 240 V AC or 415 V AC primary supply.
  • 24 V AC secondary output: Provides a nominal low-voltage AC supply for compatible industrial control equipment.
  • 400 VA rated capacity: Suitable for control circuits with substantial combined 24 V AC load requirements.
  • Single-phase construction: Designed for single-phase industrial control transformer applications.
  • Selectable primary connections: 0/240/415 V terminals accommodate the two specified input voltages.
  • Single-voltage secondary: 0/24 V terminals simplify integration into compatible control systems.
  • Continuous-duty design: Intended for sustained operation within specified limits.
  • Class E insulation: Supports the transformer's electrical insulation requirements.
  • 8% voltage regulation: Provides a defined regulation characteristic for load assessment.
  • IP20 touch-proof terminals: Help reduce accidental contact with live terminal parts.
  • Class H varnish impregnation: Provides protective treatment for the transformer windings.
  • Core earth connection: Supports protective earthing within a correctly designed installation.
  • 50/60 Hz operation: Suitable for the specified AC supply frequencies.
  • Industrial dimensions: 120 × 108 × 120 mm for electrical panel planning.
  • Enclosure options: EPH 3 or EPN 2 references are specified for this model.

Key Features

  • ETE DV dual-input-voltage control transformer series.
  • 400 VA rated apparent power.
  • Single-phase transformer configuration.
  • 240 V AC or 415 V AC selectable primary input.
  • 0/240/415 V primary terminal arrangement.
  • 0/24 V secondary terminal arrangement.
  • 24 V AC nominal output connection.
  • 50/60 Hz rated operating frequency.
  • Continuous-rated control circuit transformer.
  • Class E electrical insulation.
  • 8% specified voltage regulation.
  • IP20 touch-proof connection terminals.
  • Class H varnish-impregnated construction.
  • Dedicated core earth connection.
  • Dual-voltage primary and single-voltage secondary.
  • 120 × 108 × 120 mm overall dimensions.
  • 5.5 kg specified weight.
  • EPH 3 or EPN 2 enclosure references.

Reliable 24 V AC Control Power from 240 V or 415 V Supplies

The ETE DV400P6S6 is designed for industrial electrical installations where the available primary supply may be either 240 V AC or 415 V AC. Its tapped primary winding features 0/240/415 V terminals, allowing the correct input connection to be selected during installation. When supplied through the appropriate primary terminals, the transformer provides a nominal 24 V AC secondary output through its 0/24 V terminals.

This dual-input arrangement is useful for electrical panel builders and OEM machinery manufacturers producing equipment for different supply configurations. On a 415 V AC supply, the transformer steps the voltage down to 24 V AC. On a 240 V AC supply, it also provides a nominal 24 V AC output when the correct primary terminals are used. The two primary voltage options are alternative connections and must not be treated as independent supplies that can be connected simultaneously.

The 400 VA rating corresponds to a calculated nominal full-load secondary current of approximately 16.67 A at 24 V AC. This value is obtained by dividing the transformer's rated apparent power by its nominal secondary voltage. Engineers should consider the combined apparent power of connected equipment, load characteristics, permissible voltage variation and any short-duration inrush requirements when determining whether the DV400P6S6 is suitable for a particular application.

The specified 8% voltage regulation is an important consideration for 24 V AC control circuits with defined operating voltage tolerances. Voltage regulation relates to the change in secondary voltage between no-load and rated-load conditions under the relevant test conditions. The actual secondary voltage may therefore vary with primary supply voltage and connected load rather than remaining exactly 24 V AC at all times.

The DV400P6S6 incorporates Class E insulation, IP20 touch-proof terminals, Class H varnish impregnation and a core earth connection. For installations requiring additional protection, the specified enclosure references are EPH 3 or EPN 2. Appropriate primary and secondary overcurrent protection, conductor sizing, protective earthing, ventilation and mounting arrangements must be considered during installation.

Typical Applications

  • Industrial electrical control panels requiring a 24 V AC control supply.
  • Machinery designed for either 240 V AC or 415 V AC primary supplies.
  • OEM machinery manufacturing and electrical panel-building projects.
  • Factory automation and industrial process control equipment.
  • AC contactor and relay control circuits designed for 24 V AC.
  • Industrial switching and electrical control assemblies.
  • Packaging, processing and manufacturing machinery.
  • Electrical distribution and control cabinet installations.
  • Auxiliary circuits designed for 24 V AC operation.
  • Industrial equipment incorporating multiple compatible 24 V AC loads.
  • Control panels requiring flexibility between supported primary supply voltages.
  • Maintenance and replacement applications requiring a compatible 400 VA dual-input control transformer.
  • Electrical installations requiring 240 V to 24 V AC or 415 V to 24 V AC voltage conversion.

Selecting the Correct 400 VA Control Transformer

When selecting the ETE DV400P6S6 400 VA transformer, confirm that the available primary supply is either 240 V AC or 415 V AC and that the connected equipment requires a nominal 24 V AC supply. The combined apparent power of the connected loads must remain within the transformer's 400 VA rating, with suitable allowance for equipment starting characteristics and transient demands.

At 24 V AC, the transformer has a calculated full-load secondary current of approximately 16.67 A. Secondary wiring, terminals and protective devices must therefore be selected for the intended circuit conditions. The 8% voltage regulation should also be considered when assessing whether connected relays, contactors and other control devices will operate reliably throughout their expected voltage range.

The transformer's Class E insulation, 120 × 108 × 120 mm dimensions and 5.5 kg weight should be considered during mechanical and thermal design. The specified EPH 3 or EPN 2 enclosure references provide a starting point for enclosure selection, while final installation arrangements should follow the manufacturer's documentation and applicable electrical regulations.

Technical Specifications

Tick the specs you need, then view products that match.

Manufacturer Eastern Transformers & Equipment (ETE)
Rated Power (VA) 400 VA
Primary Voltage 0/240/415V
Secondary Voltage 0/24V
Phase Single Phase
Series DV Dual-Input-Voltage Stock Control Transformer Range
Model DV400P6S6
Product type Industrial control circuit transformer
Transformer configuration Dual-input-voltage primary, single-voltage secondary
Number of phases Single-phase
Rated apparent power 400 VA
Primary voltage options 240 V AC or 415 V AC
Primary terminals 0/240/415 V
Secondary voltage 24 V AC
Secondary terminals 0/24 V
Output connection 24 V
Rated frequency 50/60 Hz
Duty rating Continuous
Insulation class Class E
Varnish impregnation Class H
Voltage regulation 8%
Terminal protection IP20 touch-proof terminals
Core earthing Core earth connection
Ambient operating temperature −10 °C to +35 °C
Design standard EN 61558-1
Calculated full-load secondary current Approximately 16.67 A
Calculated ideal primary current at 240 V AC Approximately 1.67 A, excluding losses
Calculated ideal primary current at 415 V AC Approximately 0.96 A, excluding losses
Length 120 mm
Width 108 mm
Height 120 mm
Dimensions (L × W × H) 120 × 108 × 120 mm
Weight 5.5 kg
Enclosure reference EPH 3 or EPN 2
Installation type Electrical control panel or suitable enclosure installation
Product range reference ETE Stock Control Transformer Range, March 2026

Frequently Asked Questions

What is the ETE DV400P6S6 transformer used for?

The ETE DV400P6S6 is a 400 VA single-phase dual-input-voltage control transformer designed to provide a nominal 24 V AC output from either a 240 V AC or 415 V AC primary supply. It is suitable for compatible industrial machinery control circuits and auxiliary electrical equipment.

What does dual-input voltage mean on the ETE DV400P6S6?

Dual-input voltage means the transformer has 0/240/415 V primary terminals, allowing the appropriate connection to be selected for either a 240 V AC or 415 V AC supply. Only the correct primary connection for the available supply should be used.

What is the power rating of the ETE DV400P6S6?

The ETE DV400P6S6 has a rated apparent power of 400 VA. The combined connected load must remain within the transformer's rating and applicable operating limits.

What are the primary and secondary terminal connections?

The transformer has 0/240/415 V primary terminals and 0/24 V secondary terminals. When correctly connected to either supported primary supply voltage, it provides a nominal 24 V AC secondary output.

What is the calculated full-load secondary current of the ETE DV400P6S6?

Based on its 400 VA rating and 24 V AC secondary voltage, the calculated full-load secondary current is approximately 16.67 A. Actual transformer selection should also account for connected load characteristics and inrush requirements.

What insulation class does the ETE DV400P6S6 use?

The DV400P6S6 uses a Class E insulation system. The ETE DV transformer range is designed to EN 61558-1 and incorporates protective Class H varnish impregnation.

What are the dimensions and weight of the ETE DV400P6S6?

The transformer measures 120 mm long, 108 mm wide and 120 mm high, with a specified weight of 5.5 kg.

What is the voltage regulation of the ETE DV400P6S6?

The ETE DV400P6S6 has a specified 8% voltage regulation. This should be considered when assessing the secondary voltage requirements of connected equipment under different load conditions.

Which enclosure is specified for the ETE DV400P6S6?

The specified enclosure references are EPH 3 or EPN 2. The correct enclosure should be selected according to the installation environment, transformer dimensions, ventilation requirements and applicable electrical safety regulations.

Can the ETE DV400P6S6 be installed inside an industrial control panel?

Yes. The DV400P6S6 is intended for industrial control applications and can be incorporated into a suitably designed electrical control panel or enclosure, subject to appropriate mounting, ventilation, circuit protection and protective earthing.

Does the ETE DV400P6S6 provide a 24 V DC output?

No. The ETE DV400P6S6 provides a nominal 24 V AC secondary output, not 24 V DC. Applications requiring direct current need a suitable DC power supply or appropriately rated rectification and conditioning equipment.

Can both primary voltage connections be used at the same time?

No. The 0/240/415 V primary terminals provide alternative connections for the two supported input voltages. The transformer must be connected using the correct terminals for the available supply, following the manufacturer's instructions. It is not designed to combine two independent primary supplies.

Designed for Industrial Panel Builders and Automation Engineers

The ETE DV400P6S6 combines dual-input-voltage flexibility with a 400 VA rating and a nominal 24 V AC secondary output. Its selectable 240 V AC or 415 V AC primary connection, Class E insulation, 8% voltage regulation and industrial construction make it a practical choice for electrical control panels, OEM machinery and automation applications requiring a dedicated low-voltage AC control supply.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Priority sourcing and supply support

 Flexible payment terms for qualifying organisations

 Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...