ETE MV150P1S1 Multi-Voltage Control Transformer 150VA 10/0/220/240V to 0/55/110V

ETE MV150P1S1 Multi-Voltage Control Transformer 150VA 10/0/220/240V to 0/55/110V

ETE MV150P1S1 is a 150 VA single-phase multi-voltage control transformer featuring 10/0/220/240 V primary terminals with a 10 V adjustment tap, selectable 55 V or 110 V AC secondary connections, Class E insulation and 10% voltage regulation.

SKU: MV150P1S1MPN: MV150P1S1
Price
List Price £43.90 ex VAT
Your Price (ex VAT)
£43.90
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

SUBTOTAL (EX VAT) £43.90
Trade pricing is personalised to your account

Manufacturer Lead Time

£43.90

Why Choose the ETE MV150P1S1 150 VA Multi-Voltage Control Transformer?

The ETE MV150P1S1 is a versatile 150 VA single-phase multi-voltage control transformer designed for industrial electrical control circuits requiring flexible primary voltage connections and selectable 55 V AC or 110 V AC secondary outputs. Manufactured by Eastern Transformers & Equipment (ETE), this transformer belongs to the ETE MV Multi-Voltage Series, providing a practical power supply solution for electrical control panels, machinery, automation equipment and OEM installations.

Featuring a 10/0/220/240 V primary terminal arrangement and 0/55/110 V secondary terminals, the MV150P1S1 offers multiple connection options for industrial control applications. Its secondary winding arrangement is also described by ETE as 55/0/55 V (0/55/110 V), allowing the appropriate output connections to be selected for the intended circuit.

The transformer has Class E insulation, 10% voltage regulation and a 150 VA rated capacity. Its compact dimensions of 96 × 76 × 103 mm and weight of 2.3 kg make it suitable for integration into industrial control cabinets. The specified enclosure references are EPH 2 or EPN 1.

Important connection note: The primary includes a 10 V adjustment tap. The exact primary connections and intended adjustment arrangement must be confirmed with ETE before installation. The terminal markings should not be interpreted as permission to apply arbitrary voltages or connect multiple supplies simultaneously.

Key Advantages

  • Multi-voltage primary arrangement: Features 10/0/220/240 V primary terminals for flexible supply connection options.
  • Selectable secondary voltage: Provides 55 V AC or 110 V AC output connection options.
  • 150 VA rated capacity: Suitable for appropriately sized industrial control and signalling circuits.
  • 10 V primary adjustment tap: Offers an additional primary connection feature, subject to confirmation of the correct arrangement with ETE.
  • Class E insulation: Provides a defined insulation classification for transformer operation.
  • 10% voltage regulation: Supplies a specified regulation characteristic for control circuit design.
  • Compact dimensions: Measures just 96 × 76 × 103 mm.
  • Manageable weight: Weighs 2.3 kg for installation within suitable electrical panels.
  • Continuous-rated construction: Designed for industrial control circuit operation.
  • IP20 touch-proof terminals: Help reduce accidental contact with terminal connections.
  • Class H varnish impregnation: Supports durable winding construction.
  • Protective core earth connection: Supports appropriate electrical earthing arrangements.
  • DIN rail mounting option: Offers additional installation flexibility for compatible mounting arrangements.
  • Enclosure compatibility: Specified enclosure references EPH 2 or EPN 1.

Key Features

  • ETE MV Multi-Voltage Series control transformer.
  • 150 VA rated apparent power.
  • Single-phase transformer configuration.
  • 10/0/220/240 V primary terminal arrangement.
  • 10 V primary adjustment tap.
  • 0/55/110 V secondary terminal arrangement.
  • 55/0/55 V secondary winding configuration.
  • Selectable 55 V AC or 110 V AC secondary output connections.
  • 50/60 Hz operating frequency.
  • Class E insulation system.
  • 10% specified voltage regulation.
  • Continuous-rated industrial control transformer.
  • IP20 touch-proof electrical terminals.
  • Class H varnish-impregnated windings.
  • Protective core earth connection.
  • Designed to EN 61558-1.
  • Specified ambient temperature range of −10 to +35 °C.
  • DIN rail mounting option.
  • 96 × 76 × 103 mm overall dimensions.
  • 2.3 kg product weight.
  • EPH 2 or EPN 1 enclosure references.

Flexible Primary Connections with a 10 V Adjustment Tap

The ETE MV150P1S1 multi-voltage transformer incorporates a 10/0/220/240 V primary terminal arrangement, providing greater connection flexibility than a transformer with a single fixed primary voltage. This configuration is particularly useful for electrical panel builders and OEM equipment manufacturers working with industrial control systems that require different nominal primary voltage connections.

The primary arrangement includes a 10 V adjustment tap. This tap is a specific feature of the P1 primary winding configuration and should only be used according to the manufacturer's wiring instructions. Confirm the exact primary terminal connections and the function of the 10 V adjustment tap with ETE before energising the transformer.

Correct primary selection is essential for obtaining the intended secondary output and avoiding incorrect excitation of the transformer winding. The supply voltage, operating frequency and connection arrangement should therefore be checked during panel design, installation and commissioning.

Selectable 55 V and 110 V Secondary Output Connections

The MV150P1S1 features a 0/55/110 V secondary terminal arrangement, also identified by ETE as 55/0/55 V (0/55/110 V). This provides access to nominal 55 V AC and 110 V AC secondary connections, offering flexibility for industrial control circuits with different voltage requirements.

At the full 110 V AC output, the transformer has a calculated secondary current of approximately 1.36 A based on its 150 VA rating. At 55 V AC, dividing the total apparent power rating by the output voltage gives a theoretical current of approximately 2.73 A; however, the permissible current from an individual 55 V tapping must be confirmed against the manufacturer's winding and loading specifications.

The transformer's 10% voltage regulation should be considered when selecting connected equipment, particularly for circuits with varying loads or contactor energisation demands. The total connected load, permissible tap loading and inrush requirements should be assessed before the transformer is selected for an installation.

Compact Construction for Industrial Electrical Control Panels

With dimensions of 96 mm in length, 76 mm in width and 103 mm in height, the ETE MV150P1S1 offers a compact footprint for industrial electrical cabinets and machinery control panels. Its 2.3 kg weight allows it to be accommodated within appropriately designed mounting arrangements.

The transformer is part of ETE's continuous-rated MV control transformer range, featuring Class E insulation, Class H varnish impregnation, IP20 touch-proof terminals and a protective core earth connection. The range is designed to EN 61558-1 and specifies an ambient operating temperature range of −10 to +35 °C.

A DIN rail mounting option is available for transformers in this size range, providing additional flexibility for panel assembly. The specified enclosure references are EPH 2 or EPN 1. Appropriate mechanical support, ventilation, protective devices and wiring arrangements should be incorporated into the complete electrical installation.

Typical Applications

  • Industrial control panels requiring 55 V AC or 110 V AC control supplies.
  • Electrical machinery with multi-voltage transformer requirements.
  • Industrial contactor and relay control circuits.
  • Motor starter and motor control assemblies.
  • Factory automation and production machinery.
  • OEM electrical equipment and machinery manufacturing.
  • Control circuit voltage adaptation within electrical cabinets.
  • Industrial switching and signalling applications.
  • Panel building and electrical system integration.
  • Machinery refurbishment and control transformer replacement.
  • Electrical installations requiring selectable secondary voltage taps.
  • Applications requiring a compact 150 VA single-phase multi-voltage control transformer.

Technical Specifications

Tick the specs you need, then view products that match.

Manufacturer Eastern Transformers & Equipment (ETE)
Rated Power (VA) 150 VA
Primary Voltage 10/0/220/240V
Secondary Voltage 0/55/110V
Phase Single Phase
Manufacturer part number MV150P1S1
Product series MV Multi-Voltage Series
Product type Multi-voltage control circuit transformer
Number of phases Single-phase
Rated apparent power 150 VA
Primary terminal arrangement 10/0/220/240 V
Primary voltage connections 220 V and 240 V nominal connections, with a 10 V adjustment tap requiring manufacturer confirmation
Primary adjustment tap 10 V — confirm exact connections with ETE
Secondary terminal arrangement 0/55/110 V
Secondary winding arrangement 55/0/55 V (0/55/110 V)
Secondary output connections 55 V AC or 110 V AC
Calculated secondary current at 110 V Approximately 1.36 A at 150 VA
Calculated secondary current at 55 V Approximately 2.73 A at 150 VA, subject to the manufacturer's permitted tapping and loading arrangements
Operating frequency 50/60 Hz
Insulation class E
Voltage regulation 10%
Terminal protection IP20 touch-proof terminals
Winding impregnation Class H varnish
Core earth connection Provided
Ambient operating temperature −10 to +35 °C
Design standard EN 61558-1
Duty rating Continuous
Mounting Panel mounting with DIN rail mounting option
Length 96 mm
Width 76 mm
Height 103 mm
Dimensions (L × W × H) 96 × 76 × 103 mm
Weight 2.3 kg
Enclosure references EPH 2 or EPN 1
Manufacturer catalogue reference ETE Stock Control Transformer Range, March 2026

Frequently Asked Questions

What is the ETE MV150P1S1 control transformer used for?

The ETE MV150P1S1 is a 150 VA single-phase multi-voltage control transformer designed to supply compatible industrial control circuits through selectable 55 V AC or 110 V AC secondary connections. Typical applications include electrical control panels, relays, contactors and machinery control equipment.

What are the primary voltage connections on the MV150P1S1?

The transformer has 10/0/220/240 V primary terminals, including a 10 V adjustment tap. The exact connections and adjustment tap arrangement must be confirmed with ETE before installation or energisation.

Can the ETE MV150P1S1 provide both 55 V and 110 V outputs?

Yes. Its 0/55/110 V secondary terminal arrangement provides nominal 55 V AC and 110 V AC connection options. The permissible loading of each tap and any simultaneous use must be checked against the manufacturer's connection instructions.

What is the rated secondary current of the MV150P1S1?

The transformer is rated at 150 VA. At 110 V AC, the calculated secondary current is approximately 1.36 A. At 55 V AC, the theoretical value calculated from 150 VA is approximately 2.73 A, but the permissible current from the individual 55 V tapping must be confirmed with ETE.

What is the purpose of the 10 V primary adjustment tap?

The 10 V adjustment tap forms part of the transformer's multi-voltage primary arrangement. Its exact function and connection method must be confirmed with ETE. Installers should not assume a wiring configuration based solely on the terminal markings.

What are the dimensions and weight of the ETE MV150P1S1?

The transformer measures 96 × 76 × 103 mm (length × width × height) and weighs 2.3 kg.

What insulation class and voltage regulation does the MV150P1S1 have?

The MV150P1S1 features Class E insulation and 10% voltage regulation. ETE also specifies Class H varnish impregnation, IP20 touch-proof terminals and a protective core earth connection for this transformer.

Which enclosures are specified for the ETE MV150P1S1?

The specified enclosure references are EPH 2 or EPN 1. The final enclosure selection should account for mounting, ventilation, electrical protection and the environmental requirements of the installation.

Trusted by Industrial Panel Builders and Automation Engineers

The ETE MV150P1S1 provides a versatile solution for industrial control power requirements, combining a 150 VA rating with multi-voltage primary connections and selectable 55 V or 110 V secondary outputs. Its Class E insulation, 10% voltage regulation, compact dimensions and EPH 2 or EPN 1 enclosure options make it a practical choice for panel builders, OEM machinery manufacturers and industrial electrical engineers. The 10 V primary adjustment tap should be connected only after confirming the correct arrangement with ETE.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Priority sourcing and supply support

 Flexible payment terms for qualifying organisations

 Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...