ETE MV50P2S1 Multi-Voltage Control Transformer 50VA 20/0/380/420V to 0/55/110V

ETE MV50P2S1 Multi-Voltage Control Transformer 50VA 20/0/380/420V to 0/55/110V

ETE MV50P2S1 is a 50 VA single-phase multi-voltage control transformer with 20/0/380/420 V primary terminals, selectable 55 V or 110 V AC secondary taps, a 20 V primary adjustment tap requiring ETE connection confirmation, Class E insulation and 15% voltage regulation.

SKU: MV50P2S1MPN: MV50P2S1
Price
List Price £28.30 ex VAT
Your Price (ex VAT)
£28.30
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

SUBTOTAL (EX VAT) £28.30
Trade pricing is personalised to your account

Manufacturer Lead Time

£28.30

Why Choose the ETE MV50P2S1 50 VA Multi-Voltage Control Transformer?

The ETE MV50P2S1 is a 50 VA single-phase multi-voltage control transformer designed for industrial electrical installations requiring flexible primary voltage connections and selectable secondary output voltages. Part of the ETE MV multi-voltage transformer range, it features 20/0/380/420 V primary terminals and 0/55/110 V secondary terminals, allowing the selection of a nominal 55 V AC or 110 V AC output using the appropriate secondary tap.

Its multi-voltage arrangement makes the MV50P2S1 a practical solution for electrical panel builders, machinery manufacturers and maintenance engineers working with compatible industrial control systems. The transformer provides dedicated AC voltage transformation for control circuits, signalling equipment and other devices requiring a suitable 55 V AC or 110 V AC supply.

The transformer includes a 20 V primary adjustment tap, which provides an additional connection facility within the primary winding arrangement. The correct use of this adjustment tap and the required primary terminal connections must be confirmed with ETE before installation. The terminal markings alone should not be used to infer an unverified connection arrangement.

With Class E insulation, a specified 15% voltage regulation, dimensions of 75 × 65 × 88 mm and a weight of approximately 1 kg, the MV50P2S1 provides a compact control transformer option. The associated enclosure references are EPH 1 or EPN 1, allowing suitable enclosure arrangements to be identified for the application.

Key Advantages

  • 50 VA rated capacity provides dedicated AC power for compatible low-power industrial control circuits.
  • Multi-voltage primary arrangement incorporates 20/0/380/420 V terminals for applications requiring the manufacturer's specified connection configurations.
  • Selectable 55 V AC or 110 V AC secondary output supports different control voltage requirements using the appropriate secondary tap.
  • 20 V primary adjustment tap provides an additional connection facility, subject to confirmation of the correct wiring arrangement with ETE.
  • Single-phase construction supports dedicated control voltage transformation.
  • Compact dimensions of 75 × 65 × 88 mm assist with electrical panel space planning.
  • Approximately 1 kg weight makes the transformer practical to accommodate within suitable control equipment assemblies.
  • Class E insulation provides a defined thermal insulation classification.
  • 15% specified voltage regulation provides useful information when assessing secondary voltage variation under changing load conditions.
  • EPH 1 or EPN 1 enclosure references help identify associated enclosure options.
  • Selectable secondary taps reduce the need for separate transformer models when either supported output voltage is required.
  • Industrial control transformer design is suitable for integration into appropriately protected machinery and automation circuits.

Key Features

  • ETE MV multi-voltage control transformer series.
  • 50 VA rated apparent power.
  • 0.05 kVA transformer capacity.
  • Single-phase transformer configuration.
  • Primary terminals: 20/0/380/420 V.
  • Primary voltage connection positions: 380 V and 420 V markings, with a separate 20 V adjustment tap.
  • Secondary terminals: 0/55/110 V.
  • Selectable nominal secondary output: 55 V AC or 110 V AC.
  • Secondary output selection: Appropriate 0/55 V or 0/110 V tap connection.
  • 20 V primary adjustment facility: Connection details must be confirmed with ETE.
  • Insulation class: E.
  • Specified voltage regulation: 15%.
  • Associated enclosure references: EPH 1 or EPN 1.
  • Length: 75 mm.
  • Width: 65 mm.
  • Height: 88 mm.
  • Weight: 1 kg.
  • Suitable for appropriately designed industrial electrical installations requiring a low-power 55 V AC or 110 V AC control supply.

Flexible 55 V and 110 V AC Control Power for Industrial Applications

The ETE MV50P2S1 provides a flexible solution for industrial installations requiring selectable control voltages from a single transformer. Its 0/55/110 V secondary terminal arrangement allows an appropriately connected circuit to receive a nominal 55 V AC or 110 V AC supply. This can be useful when designing or maintaining machinery with different control voltage requirements.

The transformer's 50 VA rated capacity is suitable for compatible low-power control equipment, including selected relay coils, indication circuits and signalling devices. At the rated apparent power, the calculated secondary current is approximately 0.91 A at 55 V or 0.45 A at 110 V. These values are calculated from the transformer rating and nominal output voltages; they are not separately verified manufacturer current ratings. The 50 VA capacity is the overall transformer rating and must not be interpreted as 50 VA independently available from each tap at the same time.

The 20 V primary adjustment tap is an important feature of the MV50P2S1. Because its terminal arrangement includes 20/0/380/420 V markings, installers must follow the correct manufacturer-defined wiring configuration. Confirm the appropriate connections with ETE before energising the transformer, particularly where the adjustment tap is being considered. Incorrect primary connections can result in unsuitable secondary voltages or equipment damage.

The specified 15% voltage regulation is relevant when assessing output voltage variation between operating conditions. The actual secondary voltage can vary with supply voltage and connected load, so equipment with narrow operating voltage tolerances should be checked for compatibility. This is particularly important for low-power transformers supplying contactors, relays or electronic equipment with specific voltage requirements.

With its Class E insulation, compact dimensions and EPH 1 or EPN 1 enclosure references, the MV50P2S1 can be incorporated into suitably engineered electrical installations. Appropriate mounting, primary and secondary circuit protection, conductor sizing, ventilation and electrical clearances must be provided in accordance with the manufacturer's instructions and applicable installation requirements.

Typical Applications

  • Industrial control circuits requiring a nominal 55 V AC supply.
  • Industrial control circuits requiring a nominal 110 V AC supply.
  • Electrical control panels with compatible 380 V or 420 V primary supply arrangements.
  • Industrial machinery and OEM control equipment.
  • Low-power relay and contactor control circuits with compatible AC coil voltages.
  • Industrial signalling and indication equipment.
  • Machinery electrical cabinets and control enclosures.
  • Control transformer replacement and maintenance projects.
  • Electrical panel building and automation system integration.
  • Equipment requiring selectable 55 V or 110 V AC control power.
  • Industrial process control equipment with suitable low-power AC loads.
  • Control circuit upgrades requiring a compact 50 VA multi-voltage transformer.

Technical Specifications

Tick the specs you need, then view products that match.

Manufacturer ETE
Rated Power (VA) 50 VA
Primary Voltage 20/0/380/420V
Secondary Voltage 0/55/110V
Phase Single Phase
Series MV Multi-Voltage Control Transformers
Model MV50P2S1
Product type Multi-voltage control transformer
Transformer configuration Single-phase
Rated apparent power 50 VA
Rated capacity 0.05 kVA
Primary terminal markings 20/0/380/420 V
Primary voltage positions 380 V and 420 V
Primary adjustment tap 20 V
Primary connection requirement Confirm correct adjustment tap and supply connections with ETE
Secondary terminal markings 0/55/110 V
Secondary output option 1 55 V AC
Secondary output option 2 110 V AC
Secondary output connection 55 V or 110 V taps
Calculated secondary current at 55 V Approximately 0.91 A at 50 VA
Calculated secondary current at 110 V Approximately 0.45 A at 50 VA
Insulation class E
Voltage regulation 15%
Length 75 mm
Width 65 mm
Height 88 mm
Dimensions (L × W × H) 75 × 65 × 88 mm
Weight 1 kg
Enclosure reference EPH 1 or EPN 1
Product range ETE Stock Control Transformers
Catalogue reference ETE Stock Control Transformer Range, March 2026

Frequently Asked Questions

What is the ETE MV50P2S1 used for?

The ETE MV50P2S1 is a 50 VA single-phase multi-voltage control transformer used to provide a selectable nominal 55 V AC or 110 V AC secondary supply for compatible industrial control circuits, electrical panels and machinery.

What is the power rating of the ETE MV50P2S1?

The transformer has a rated apparent power of 50 VA (0.05 kVA). The connected load must remain within the transformer's overall rated capacity.

What primary terminals does the MV50P2S1 have?

The transformer has 20/0/380/420 V primary terminals. These include a 20 V adjustment tap. The correct supply and adjustment tap connections must be confirmed with ETE before installation.

What secondary voltages can the MV50P2S1 provide?

The transformer features 0/55/110 V secondary terminals and supports a nominal 55 V AC or 110 V AC output, depending on the selected secondary connection.

What is the purpose of the 20 V primary adjustment tap?

The 20 V primary adjustment tap provides an additional connection facility within the transformer's primary arrangement. Its correct use and wiring configuration must be confirmed with ETE; the terminal markings alone should not be used to assume a particular adjustment connection.

Can the MV50P2S1 supply 55 V and 110 V AC at the same time?

The transformer has 0/55/110 V secondary taps, but its specified output connection is 55 V or 110 V. Simultaneous loading of both taps should not be assumed without confirmation from ETE, and the total load must remain within the 50 VA rating.

What is the calculated secondary current at 55 V?

At a nominal 55 V AC output, the calculated current corresponding to the 50 VA rating is approximately 0.91 A. This is a calculated value rather than a separately verified manufacturer current rating.

What is the calculated secondary current at 110 V?

At a nominal 110 V AC output, the calculated current corresponding to the 50 VA rating is approximately 0.45 A. This is a calculated value rather than a separately verified manufacturer current rating.

What does the 15% voltage regulation specification mean?

The MV50P2S1 has a specified 15% voltage regulation. Transformer voltage regulation describes the change in secondary voltage between defined load conditions, so connected equipment should be selected with suitable voltage tolerance.

What insulation class does the ETE MV50P2S1 use?

The transformer uses Class E insulation, providing a defined thermal insulation classification for its winding insulation system.

What are the dimensions and weight of the ETE MV50P2S1?

The transformer measures 75 × 65 × 88 mm (L × W × H) and weighs approximately 1 kg. These details assist with electrical panel layout and mechanical installation planning.

Which enclosure references are associated with the MV50P2S1?

The associated enclosure references are EPH 1 or EPN 1. The appropriate enclosure arrangement and its suitability for the installation should be confirmed before selection.

Is the ETE MV50P2S1 suitable for industrial control panels?

Yes. The MV50P2S1 is a multi-voltage control transformer suitable for appropriately designed industrial control panels requiring a compatible 55 V AC or 110 V AC supply within its 50 VA capacity.

What should be checked before installing the ETE MV50P2S1?

Before installation, confirm the correct 20/0/380/420 V primary connections and the use of the 20 V adjustment tap with ETE. Select the appropriate 55 V or 110 V secondary connection, check the total connected load against the 50 VA rating, and provide suitable circuit protection, wiring, mounting, ventilation and electrical clearances.

Trusted by Industrial Panel Builders and Automation Engineers

ETE MV multi-voltage control transformers offer a practical solution for industrial applications requiring flexible AC voltage transformation and selectable control voltages. With 20/0/380/420 V primary terminals, 55 V or 110 V secondary output options, a 50 VA rating, Class E insulation and a compact design, the MV50P2S1 provides electrical panel builders, machinery manufacturers and maintenance engineers with a versatile option for low-power industrial control circuits.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Priority sourcing and supply support

 Flexible payment terms for qualifying organisations

 Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...