Finder 7F.30.8.230.2055.7 – 230 V AC Outdoor Filter Fan, Size 2, 55 m³/h, IP54, RAL 7035
The Finder 7F.30.8.230.2055.7 is a 230 V AC outdoor filter fan designed for ventilation and thermal management in industrial electrical enclosures, outdoor control cabinets and switchboards. Part of the Finder 7F Series, this Size 2 fan combines active air circulation with a replaceable filter mat and a RAL 7035 light grey housing.
The product is the RAL 7035 colour variant of the Finder 7F.30.8.230.2055 outdoor filter fan. It provides a nominal 55 m³/h free-air volume at 50 Hz and is designed to introduce filtered external air into an electrical enclosure, helping displace warm air through a suitable exhaust opening.
With IP54 ingress protection, IK08 impact resistance and a NEMA Type 3R classification, the Finder 7F.30.8.230.2055.7 is suitable for appropriately designed outdoor electrical enclosure installations.
Its compact 155 × 155 mm front housing, 125 × 125 mm nominal mounting cut-out and convenient push-in electrical terminals make it a practical solution for panel builders, machine manufacturers, electrical engineers and industrial maintenance teams.
Key Advantages
- RAL 7035 light grey finish complements common industrial electrical enclosure colours.
- Designed for outdoor use in suitably rated electrical cabinets and control panels.
- 230 V AC operation supports compatible industrial electrical supplies.
- 55 m³/h free-air volume at 50 Hz provides forced ventilation for suitable enclosures.
- IP54 ingress protection helps limit harmful dust ingress and splashing water.
- IK08 impact resistance supports demanding industrial installations.
- NEMA Type 3R classification supports appropriately installed outdoor enclosure applications.
- Size 2 construction provides a compact ventilation solution.
- Replaceable filter mat simplifies inspection and routine maintenance.
- Push-in electrical terminals support convenient installation.
- Ball-bearing fan motor supports reliable operation.
- Approximately 42 dB(A) noise level supports relatively quiet ventilation.
- −30 to +55 °C operating temperature range suits a variety of industrial environments.
- Suitable for thermostat control using an appropriately rated switching device.
Key Features
- Finder 7F Series outdoor enclosure filter fan.
- Type 7F.30 standard-flow intake configuration.
- Manufacturer part number: 7F.30.8.230.2055.7.
- Colour variant: RAL 7035 light grey.
- Size 2 filter fan assembly.
- 230 V AC nominal operating voltage.
- 50/60 Hz supply frequency.
- 55 m³/h nominal free-air volume at 50 Hz.
- 63 m³/h nominal free-air volume at 60 Hz.
- Approximately 45.5 m³/h filtered airflow under the published reference configuration.
- IP54 ingress protection.
- IK08 impact resistance.
- NEMA Type 3R classification.
- 155 × 155 mm front housing.
- 125 × 125 mm nominal panel cut-out.
- Push-in electrical connection.
- Integrated AC axial fan motor.
- Ball-bearing construction.
- Replaceable filter element.
- Designed for outdoor electrical enclosure thermal management.
Technical Specifications
- Manufacturer: Finder
- Series: 7F Series
- Type: 7F.30
- Manufacturer part number: 7F.30.8.230.2055.7
- Base model: 7F.30.8.230.2055
- Variant: RAL 7035 light grey
- Product type: Outdoor filter fan
- Application: Electrical enclosure ventilation
- Airflow direction: Standard-flow intake
- Fan size: Size 2
- Nominal supply voltage: 230 V AC
- Supply frequency: 50/60 Hz
- Free-air volume at 50 Hz: 55 m³/h
- Free-air volume at 60 Hz: 63 m³/h
- Free-air volume at 50 Hz: Approximately 32.4 CFM
- Published filtered airflow: Approximately 45.5 m³/h under the applicable reference configuration
- Rated input power: Approximately 29 W at 50 Hz
- Rated operating current: Approximately 130 mA at 50 Hz
- Front housing width: 155 mm
- Front housing height: 155 mm
- Overall housing depth: Approximately 66.2 mm
- Nominal panel cut-out: 125 × 125 mm
- Ingress protection: IP54
- Impact protection: IK08
- NEMA classification: Type 3R
- Ambient operating temperature: −30 to +55 °C
- Noise emission: Approximately 42 dB(A)
- Fan motor: Integrated AC axial fan
- Bearing type: Ball bearing
- Electrical connection: Push-in terminals
- Housing material: Flame-retardant plastic
- Housing colour: Light grey RAL 7035
- Filter element: Replaceable
- Mounting: Electrical enclosure wall or panel
- Suitable environment: Appropriately designed outdoor electrical enclosures
How the Finder 7F.30 Outdoor Filter Fan Works
The Finder 7F.30.8.230.2055.7 uses an integrated AC axial fan to draw external air through its filter assembly and introduce it into an electrical enclosure.
As electrical components operate, they generate heat that can accumulate within the cabinet. The incoming air helps displace warmer internal air through a suitable exhaust opening.
This establishes a ventilation path through the enclosure, helping maintain suitable operating temperatures for components such as relays, power supplies, PLCs, contactors and electronic control equipment.
The fan provides a nominal 55 m³/h free-air volume at 50 Hz. Actual installed airflow depends on the resistance of the filter, the exhaust opening and the overall cabinet layout.
For effective cooling, the fan should be selected according to the enclosure's internal heat dissipation, maximum ambient temperature and required airflow.
RAL 7035 Light Grey Housing
The distinguishing feature of the 7F.30.8.230.2055.7 variant is its RAL 7035 light grey housing.
RAL 7035 is commonly used for industrial electrical cabinets, switchboards and control panels, making this version suitable for installations where a coordinated enclosure appearance is required.
The standard 7F.30.8.230.2055 is listed with a grey RAL 7000 housing, while the .7 variant provides the lighter RAL 7035 finish.
When replacing an existing filter fan, the complete part number should be checked to ensure that the required colour and electrical configuration are supplied.
Outdoor Enclosure Protection
The Finder 7F.30 range is designed for outdoor electrical enclosure ventilation.
The fan incorporates an IP54 protection rating, helping protect against harmful dust ingress and splashing water under the relevant test conditions.
Its IK08 impact resistance provides additional mechanical protection, while its NEMA Type 3R classification supports suitable outdoor electrical cabinet applications.
These ratings depend on correct installation and do not mean the fan is suitable for immersion, high-pressure water jets or every possible environmental exposure.
The completed electrical enclosure should be assessed as a whole, including seals, cable entries, ventilation openings and other installed accessories.
Standard Intake Versus Reverse-Flow Exhaust Ventilation
The Finder 7F.30.8.230.2055.7 is a standard-flow intake filter fan.
It draws air from outside the enclosure through the filter mat and directs it into the cabinet.
The corresponding Finder 7F.31 range provides reverse-flow exhaust operation for applications where active air extraction is required.
Intake ventilation can help create a positive internal cabinet pressure when correctly configured with a suitable exhaust opening.
Exhaust ventilation actively removes air from the enclosure and draws replacement air through a separate inlet.
The preferred arrangement depends on cabinet geometry, airborne contamination, equipment positioning and the required thermal performance.
Replaceable Filter Mat and Maintenance
The Finder 7F.30.8.230.2055.7 includes a replaceable filter element that helps reduce the entry of airborne dust and debris with the ventilation air.
Over time, dust accumulation can increase filter resistance and reduce the volume of air entering the enclosure.
Routine inspection and filter replacement help maintain ventilation performance and reduce the likelihood of excessive cabinet temperatures.
The correct replacement filter should be selected according to Finder's Size 2 outdoor filter fan accessory information.
Maintenance intervals should reflect the surrounding environment. Outdoor cabinets exposed to dust, pollen and airborne debris may require more frequent inspection than installations in cleaner conditions.
Installation and Electrical Considerations
The Finder 7F.30.8.230.2055.7 is designed for installation into a suitable electrical enclosure wall or panel.
Its 155 × 155 mm front housing covers a nominal 125 × 125 mm mounting opening.
The fan operates from a nominal 230 V AC supply at 50/60 Hz and uses push-in electrical terminals.
The fan can be controlled using a suitable enclosure thermostat or other switching device rated for the fan's voltage and motor load.
For effective airflow, the fan should be positioned so that incoming air circulates through the cabinet rather than travelling directly to the exhaust opening.
Important: Installation should be carried out by a competent person. The exact mounting requirements, protective arrangements and terminal connections should be confirmed against Finder's current installation documentation.
Thermal Management for Industrial Electrical Cabinets
Electrical cabinets frequently contain heat-generating components such as power supplies, contactors, PLCs, relays, transformers and electronic control modules.
Excessive internal temperatures can affect equipment performance and long-term reliability.
The Finder 7F.30.8.230.2055.7 helps manage internal cabinet temperatures by introducing filtered external air and supporting the removal of accumulated heat.
Its compact Size 2 design makes it suitable for appropriately sized enclosures requiring moderate forced ventilation.
The fan should be selected according to the total internal heat load, surrounding ambient temperature and the resistance of the complete ventilation system.
Where the ambient air temperature is higher than the required internal cabinet temperature, ventilation alone may not provide sufficient cooling.
Typical Applications
- Outdoor industrial electrical control cabinets.
- RAL 7035 electrical enclosures and switchboards.
- Industrial automation control panels.
- Outdoor machinery control cabinets.
- Electrical distribution enclosures.
- Building services control systems.
- Outdoor instrumentation cabinets.
- Industrial process control installations.
- OEM machinery and panel manufacturing.
- Electrical enclosures requiring filtered intake ventilation.
- Temperature-controlled cabinet ventilation systems.
- Industrial installations using a suitable 230 V AC supply.