Why Choose the Lovato DM0TW0010 10/5 A Wound Primary Current Transformer?
The Lovato DM0TW0010 is a wound primary current transformer designed for accurate current measurement in low-current electrical circuits. With a primary current rating of 10 A and a standard 5 A secondary output, it provides the current transformation required for compatible ammeters, energy meters, power analysers and protection or monitoring equipment.
Unlike a conventional solid-core current transformer where the primary conductor passes through the transformer aperture, the DM0TW0010 uses a wound primary construction. This makes it particularly suitable for lower primary current ratings where a defined 10/5 A transformation ratio is required without arranging multiple conductor turns through a conventional current transformer.
The DM0TW0010 provides an accuracy burden of 3.75 VA for Class 0.5 and 3.75 VA for Class 1. Its standard 5 A secondary makes it suitable for integration with a wide range of compatible Lovato and third-party electrical measuring instruments designed for current transformer inputs.
Key Advantages
- 10/5 A transformation ratio for low-current measurement applications.
- Wound primary construction specifically designed for low primary current ratings.
- Standard 5 A secondary output for compatibility with common metering and monitoring equipment.
- Class 0.5 measurement capability with a 3.75 VA burden.
- Suitable for energy meters, power analysers, ammeters and electrical monitoring systems.
- Purpose-designed Lovato current transformer for industrial and commercial electrical installations.
- Compact construction suitable for installation inside electrical control and distribution panels.
Key Features
- Lovato DM0TW series current transformer.
- Wound primary design.
- 10 A primary current.
- 5 A secondary current.
- 10/5 A transformation ratio.
- 3.75 VA burden at Class 0.5.
- 3.75 VA burden at Class 1.
- Designed for connection to compatible electrical measuring instruments.
- Suitable for current, power and energy monitoring applications.
A current transformer reduces the current flowing in an electrical circuit to a proportional secondary current that can be safely measured by compatible instrumentation. The 10/5 A ratio of the DM0TW0010 means that a nominal primary current of 10 A corresponds to a 5 A secondary current, allowing suitable measuring equipment to monitor the primary circuit indirectly.
Wound primary current transformers are particularly useful at low primary current ratings because the primary winding is incorporated into the transformer rather than relying on a high-current conductor passing through an aperture. The Lovato DM0TW0010 therefore provides a practical solution for low-current metering, power analysis and electrical monitoring applications requiring a standard 5 A CT secondary.
Typical Applications
- Low-current electrical measurement.
- Energy meter current inputs.
- Power analyser installations.
- Panel-mounted ammeters and measuring instruments.
- Industrial electrical distribution panels.
- Commercial building energy monitoring.
- Machine and equipment current monitoring.
- Electrical load and consumption analysis.