Why Choose the Lovato DM1TP0060FKIT Current Transformer Kit?
The Lovato DM1TP0060FKIT is a complete current-measurement kit comprising three DM1TP0060 solid-core current transformers, each supplied with its associated UTF certificate. Each transformer has a 60/5 A transformation ratio and Class 0.5s accuracy, making the kit particularly suitable for three-phase energy-metering installations where certified current transformers are required.
Each DM1TP0060 transformer converts a nominal 60 A primary current to a standard 5 A secondary output and provides a rated secondary apparent power of 1.5 VA. The solid-core design incorporates a 28 mm opening, while the 50–60 Hz operating frequency and 720 V rated insulation voltage suit common low-voltage AC distribution and metering applications.
Supplied as a matched three-transformer kit with three UTF certificates, the DM1TP0060FKIT simplifies specification and procurement for three-phase metering projects. Screw secondary connections and support for DIN rail or screw fixing provide practical installation options inside switchboards, metering panels and electrical distribution equipment.
Key Advantages
- Complete kit containing 3 × DM1TP0060 current transformers.
- Supplied complete with 3 × UTF certificates.
- 60/5 A transformation ratio for standard 5 A metering inputs.
- Class 0.5s accuracy for precision energy-metering applications.
- 1.5 VA rated secondary apparent power.
- 28 mm opening accommodates suitable primary conductors.
- 120% continuous overload withstand relative to rated primary current.
- Flexible DIN rail or screw mounting.
- Three-transformer configuration is convenient for three-phase electrical metering.
Key Features
- Lovato DM1TP current transformer kit.
- Includes three solid-core current transformers.
- Each CT rated at 60 A primary / 5 A secondary.
- Class 0.5s measurement accuracy.
- Also specified as Class 0.5 at 1.5 VA.
- 28 mm conductor opening.
- 50–60 Hz operating frequency.
- 720 V rated insulation voltage.
- Class E dry insulation.
- Screw secondary terminals.
- DIN rail or screw fixing.
- IP30 protection rating.
- Supplied with individual UTF certification for the three included transformers.
Certified Three-Phase 60/5 A Current Measurement
The Lovato DM1TP0060FKIT provides the three current transformers typically required to measure the individual phase currents of a three-phase electrical system. Each transformer converts a nominal 60 A primary current into a proportional 5 A secondary signal for connection to compatible energy meters, multifunction instruments and power analysers.
Unlike purchasing three standard transformers individually, the DM1TP0060FKIT is supplied as a dedicated kit with three UTF certificates. The combination of Class 0.5s accuracy, 1.5 VA burden and certified transformers makes the kit particularly appropriate for energy-metering installations where documented CT characteristics are required.
Typical Applications
- Three-phase energy-metering installations.
- Certified electrical energy measurement systems.
- Electrical switchboards and distribution panels.
- Three-phase multifunction meters.
- Power analysers and network analysers.
- Industrial energy-management systems.
- Commercial electrical distribution monitoring.
- Building energy-management systems.
- Panel building and metering assemblies.
- Applications requiring 60/5 A Class 0.5s current transformers with UTF certificates.