Why Choose the Lovato DM1TP0150FKIT Current Transformer Kit?
The Lovato DM1TP0150FKIT is a certified three-current-transformer kit designed for accurate three-phase electrical metering and energy-monitoring installations. The kit comprises three Lovato DM1TP0150 solid-core current transformers, each rated at 150/5 A, together with the associated UTF certification.
Each transformer provides a standard 5 A secondary output from a rated 150 A primary current and offers Class 0.5S accuracy at 2.5 VA. Class 0.5 performance is also available at a burden of 3.75 VA, providing dependable measurement for compatible energy meters, multimeters and power analyzers.
The solid-core DM1TP0150 transformers operate at 50–60 Hz and feature 720 V rated insulation voltage, screw terminals and DIN rail or screw mounting. Supplied as a matched three-transformer package with UTF certificates, the DM1TP0150FKIT is particularly suited to three-phase metering installations requiring documented current-transformer accuracy.
Key Advantages
- Complete kit containing three DM1TP0150 current transformers.
- Supplied with UTF certification for the current transformers.
- 150/5 A transformation ratio for three-phase electrical metering.
- Class 0.5S accuracy at 2.5 VA for precision energy measurement.
- Class 0.5 accuracy at 3.75 VA.
- Flexible DIN rail or screw mounting.
- Compliant with IEC/EN 61869-1 and IEC/EN 61869-2.
Key Features
- Lovato DM1TP current transformer kit.
- Includes 3 × DM1TP0150 solid-core current transformers.
- 150 A rated primary current per transformer.
- 5 A secondary output current per transformer.
- 150/5 A transformation ratio.
- 50–60 Hz operational frequency.
- 120% continuous primary-current overload withstand.
- Class 0.5S burden: 2.5 VA.
- Class 0.5 burden: 3.75 VA.
- 720 V rated insulation voltage.
- Dry-type Class E insulation.
- IP30 protection rating.
Reliable & Certified Three-Phase Current Measurement
Current transformers allow higher AC currents to be monitored by converting primary current into a proportional secondary signal suitable for metering equipment. Each DM1TP0150 in this kit converts a rated 150 A primary current into a 5 A secondary current, allowing the three units to provide current sensing across the phases of a three-phase electrical system.
The combination of Class 0.5S accuracy, standard 5 A secondary outputs and supplied UTF certification makes the DM1TP0150FKIT particularly suitable for metering installations where documented current-transformer performance is required. Its DIN rail or screw mounting options also simplify integration into switchboards and electrical distribution panels.
Typical Applications
- Three-phase electrical energy metering.
- Industrial electrical distribution panels.
- Certified energy measurement installations.
- Energy meters and power analyzers.
- Commercial and industrial switchboards.
- Building energy-management systems.
- Electrical load and consumption monitoring.