Why Choose the Finder 6M.TA.9.024.1200 Single-Phase Power Analyser?
The Finder 6M.TA.9.024.1200 is a compact single-phase AC/DC power analyser designed for accurate electrical measurement, energy monitoring and industrial automation applications. Part of the Finder 6M Series, this multifunctional monitoring device combines current sensing, voltage measurement, power analysis and energy monitoring in one unit.
Featuring True RMS (TRMS) AC measurement and DC measurement capability, the Finder 6M.TA.9.024.1200 supports nominal currents up to 50 A, with voltage measurement capabilities extending to 800 V AC and 1,000 V DC. Its integrated current sensing arrangement eliminates the need for a separate external current transformer in suitable installations, simplifying wiring and reducing the space required for monitoring equipment.
An integrated Modbus RS485 RTU communication interface allows measurement data to be accessed by compatible PLCs, energy management systems and supervisory monitoring software. With 0.5% full-scale accuracy, bidirectional active energy measurement and a DIN rail mounting adaptor included, this power analyser provides a practical solution for monitoring electrical consumption, power quality and energy flow in commercial and industrial installations.
Key Advantages
- All-in-one single-phase power analyser combines current sensing, power measurement and energy monitoring.
- True RMS AC and DC measurement capability supports a wide range of electrical installations.
- 50 A nominal current measurement for compatible AC and DC circuits.
- Voltage measurement up to 800 V AC and 1,000 V DC for industrial and energy management applications.
- 0.5% full-scale measurement accuracy supports precise electrical monitoring.
- Bidirectional active energy measurement enables monitoring of energy import and export.
- Integrated Modbus RS485 RTU communication simplifies connection to compatible automation and monitoring systems.
- Measures voltage, current, active power, apparent power, reactive power, power factor and other electrical parameters.
- Current total harmonic distortion measurement helps assess electrical supply and load characteristics.
- 9–30 V DC external power supply provides flexibility for control panel integration.
- DIN rail mounting adaptor included for convenient installation.
- Fully configurable through the Modbus RS485 communication interface.
Key Features
- Finder 6M Series single-phase power analyser.
- AC True RMS and DC electrical measurement.
- 50 A nominal AC/DC current rating.
- 90–800 V AC voltage measurement range.
- 90–1,000 V DC voltage measurement range.
- 0.5 A minimum measured current.
- 90 A maximum measurable peak current.
- 0.5% full-scale current and voltage accuracy.
- DC and 1–400 Hz AC measurement capability.
- Bidirectional active energy measurement in kWh.
- Measurement of RMS voltage and current.
- Measurement of active, apparent and reactive power.
- Measurement of power factor and cosine phi.
- Measurement of frequency and current total harmonic distortion.
- Measurement of peak voltage and peak current.
- Modbus RS485 RTU interface for remote data acquisition.
- 1,200–115,200 bit/s configurable serial communication speed.
- Configurable Modbus communication address and register representation.
- 9–30 V DC supply voltage range.
- IP20 protection rating.
- 35 mm DIN rail mounting using the supplied adaptor.
- Suitable for industrial energy monitoring and electrical distribution applications.
Technical Specifications
- Manufacturer: Finder
- Series: 6M Series Power Analysers
- Model: 6M.TA.9.024.1200
- Product type: Single-phase AC/DC power analyser
- Measurement system: Single-phase AC and DC
- AC measurement method: True RMS (TRMS)
- Nominal AC current: 50 A
- Nominal DC current: 50 A
- Minimum measured current: 0.5 A
- Maximum measurable peak current: 90 A
- AC voltage measurement range: 90–800 V AC
- DC voltage measurement range: 90–1,000 V DC
- Current accuracy: 0.5% of full scale
- Voltage accuracy: 0.5% of full scale
- Measurement frequency: DC or 1–400 Hz AC
- Voltage measurement: RMS and peak values
- Current measurement: RMS and peak values
- Active power measurement: kW
- Apparent power measurement: kVA
- Reactive power measurement: kvar
- Power factor measurement: PF and cosφ
- Frequency measurement: Hz
- Harmonic distortion measurement: Current THD
- Energy measurement: Bidirectional active energy in kWh
- Communication interface: Modbus RS485 RTU
- RS485 communication speed: 1,200–115,200 bit/s
- Default Modbus address: 1
- Default serial communication speed: 9,600 bit/s
- Default serial data format: 8 data bits, no parity, 1 stop bit
- Register representation options: MSW first, LSW first or hundredths
- Nominal supply voltage: 24 V DC
- Supply voltage range: 9–30 V DC
- Power supply type: External DC supply
- Operating temperature range: −15 to +65 °C
- Protection rating: IP20
- Mounting type: 35 mm DIN rail using supplied adaptor
- Electrical connections: Screw terminals
- Current sensing arrangement: Integrated single-conductor pass-through sensor
- Applicable safety standard: EN 61010-1
- EAN: 8012823445717
Accurate AC/DC Power and Energy Monitoring
The Finder 6M.TA.9.024.1200 is designed to provide detailed information about electrical performance in single-phase AC and DC installations. Its integrated sensing system measures current flowing through the monitored conductor, while dedicated voltage connections allow the device to calculate electrical power and energy parameters.
For AC circuits, True RMS measurement provides meaningful readings even when current waveforms are distorted by electronic loads. The analyser measures RMS voltage and current, active power, apparent power, reactive power, frequency, power factor, peak values and current total harmonic distortion. These measurements can help engineers assess equipment operation, identify abnormal electrical conditions and monitor energy consumption.
The analyser also supports bidirectional active energy measurement, making it useful for applications where electrical energy can flow in either direction, including photovoltaic installations, battery energy systems and compatible power conversion equipment. The direction and interpretation of measured energy depend on the installation wiring and system configuration.
Through its Modbus RS485 RTU interface, the device can transmit measurement values to compatible industrial controllers, SCADA systems and energy monitoring software. It can also be integrated into Ethernet-based systems through a suitable Modbus RTU-to-TCP/IP gateway, such as the Finder 6M.BU.0.024.2200.
Typical Applications
- Single-phase AC and DC electrical energy monitoring.
- Industrial power consumption and electrical load analysis.
- Photovoltaic (PV) installations and renewable energy systems.
- Battery storage and DC power distribution monitoring.
- Electric vehicle charging equipment and associated monitoring systems.
- Industrial automation and machine energy monitoring.
- Commercial building energy management systems.
- Electrical distribution panels and control cabinets.
- Power converters, inverters and compatible DC equipment.
- PLC and SCADA data acquisition through Modbus RS485 RTU.
- Monitoring bidirectional energy flow in suitable electrical installations.
- OEM equipment requiring integrated electrical measurement and communication.