58.34.9.024.0089SMA Finder 4 CO Contacts 24V DC Modular Interface Relay with Green LED + diode Indication

58.34.9.024.0089SMA Finder 4 CO Contacts 24V DC Modular Interface Relay with Green LED + diode Indication

Finder 58.34.9.024.0089SMA four-pole relay interface module for 24 V DC control systems, with 4PDT silver-nickel contacts, 6 A hazardous-area contact rating, DIN-rail mounting, screw terminals, modular timer configuration and mechanical indicator. Listed in Finder’s ATEX and HazLoc range.

SKU: 58.34.9.024.0089SMAAlt SKU: 583490240089SMAMPN: 58.34.9.024.0089SMA
Price
List Price £109.01 ex VAT
Your Price (ex VAT)
£109.01
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

SUBTOTAL (EX VAT) £109.01
Trade pricing is personalised to your account

Manufacturer Lead Time

£109.01

Why Choose the Finder 58.34.9.024.0089SMA ATEX Interface Relay?

The Finder 58.34.9.024.0089SMA is a 24 V DC four-pole relay interface module from the Finder 58 Series, designed for industrial automation, PLC interfacing and electrical control applications where hazardous-area compliance is required. Its complete ordering code is listed in Finder's published catalogue under the ATEX and HazLoc product range.

Featuring four changeover contacts (4 CO / 4PDT), the module allows one control signal to operate four separate switching circuits. It combines an electromechanical relay with a screw-terminal interface socket and is designed for mounting on a standard 35 mm DIN rail.

Unlike standard Finder 58.34 interface modules, which have a general-purpose 7 A contact rating, the hazardous-area version has a 6 A nominal contact rating, with additional current limits depending on the certification, ambient temperature and installation arrangement. The 0089 configuration incorporates a modular timing function and a mechanical indicator, making it a specialised interface solution for suitably designed industrial control systems.

Key Advantages

  • ATEX, IECEx and HazLoc-oriented design for appropriately certified hazardous-area installations.
  • 24 V DC control supply for industrial PLC and automation systems.
  • Four changeover contacts (4 CO / 4PDT) provide flexible multi-circuit switching.
  • 6 A nominal contact rating for the hazardous-area 58.34 variant.
  • Integrated timing module configuration for applications requiring delayed relay operation.
  • Mechanical operating indicator assists with visual inspection.
  • Screw-terminal connections provide a secure wiring interface.
  • 35 mm DIN-rail mounting supports convenient control panel installation.
  • 27 mm module width supports efficient panel layout.
  • Silver-nickel (AgNi) contacts provide general-purpose switching performance.
  • Removable relay construction supports servicing and replacement.
  • Finder 58 Series compatibility simplifies integration into established relay interface systems.

Key Features

  • Finder 58 Series relay interface module.
  • 58.34 four-pole configuration.
  • 24 V DC nominal control voltage.
  • Four changeover contacts (4 CO).
  • Four-pole double-throw (4PDT) arrangement.
  • 6 A rated contact current for the hazardous-area version.
  • 15 A maximum peak contact current under specified conditions.
  • 250 V AC rated contact voltage.
  • 1,500 VA AC1 rated resistive switching capacity.
  • 350 VA AC15 switching capacity at 230 V AC.
  • Silver-nickel (AgNi) contact material.
  • Timer module configuration using Finder 86.30 technology.
  • Mechanical operating indicator.
  • Screw-terminal socket interface.
  • 35 mm DIN-rail mounting to EN 60715.
  • IECEx / ATEX hazardous-area product family.
  • HazLoc Class I, Division 2 product family.
  • IP20 interface protection classification.
  • Identification label provision.
  • Cadmium-free contacts.

Important hazardous-area rating note: Finder's 58 Series documentation specifies 6 A for a single hazardous-area 58.34 module at the relevant ATEX/IECEx conditions, reducing to 4 A for certain grouped installations at +70 °C. HazLoc ratings are 5 A under the specified +40 °C conditions. These values must not be replaced by the standard non-ATEX 7 A rating.

Exact configuration note: Finder's published price list identifies 58.34.9.024.0089SMA as an ATEX/HazLoc variant. The 58 Series ordering system identifies the 8 option position with the Finder 86.30 timing module and the final 9 with the hazardous-area version incorporating a mechanical indicator. The complete assembly's certification, permitted timing functions and any additional limitations must be checked against the current Finder approval documents.

Designed for Hazardous-Area Control Applications

The Finder 58.34.9.024.0089SMA belongs to the specialist 58 Series interface range intended for electrical equipment operating under defined hazardous-location requirements.

Finder's hazardous-area interface family includes versions designed to meet ATEX and IECEx Ex ec nC requirements and HazLoc Class I, Division 2 classifications. Such applications may include industrial process equipment, chemical handling systems and electrical control panels installed in appropriately classified environments.

Hazardous-area approval is not determined by the relay alone. The complete assembly, including its timer module, wiring, enclosure, temperature limits and installation conditions, must comply with the applicable certification. The module must not be assumed suitable for Zone 0, Zone 1 or other classifications outside its documented approval.

Integrated Timing Capability for Control Sequencing

The 0089 special configuration includes a timing-module option associated with the Finder 86.30 modular timer. This enables timed control functions in compatible relay interface assemblies, supporting applications where relay operation needs to be coordinated with other equipment.

Typical timing requirements include controlled equipment start-up, auxiliary switching delays and process sequencing. The exact selectable timing modes and adjustment range depend on the fitted timer module and should be verified against the appropriate Finder 86.30 documentation.

When a modular timer is installed, the permissible operating temperature may be narrower than that of the relay alone. Finder's 58 Series documentation identifies a −20 to +50 °C ambient range when used with an 86 modular timer, before any additional hazardous-area approval restrictions are considered.

Four Changeover Contacts for PLC and Industrial Interfacing

The Finder 58.34.9.024.0089SMA provides four changeover contact sets, allowing several electrical circuits to be controlled through one interface module.

Each pole includes a common connection, a normally open contact and a normally closed contact. This arrangement is useful where a PLC or control system needs to operate multiple auxiliary outputs, alarm signals or control circuits.

The AgNi contacts support general-purpose switching, while the hazardous-area construction requires the applicable 6 A or lower derated contact limits to be respected. Inductive and DC loads must also be assessed using their appropriate switching ratings.

DIN-Rail Mounting and Screw-Terminal Wiring

The module is designed for installation on a 35 mm DIN rail in accordance with EN 60715. Its 27 mm width supports compact integration into electrical control panels.

The screw-terminal interface provides connections for the relay contacts and control supply. Finder specifies an 8 mm wire stripping length and 0.5 Nm tightening torque for the relevant interface terminal family.

Installation in a hazardous area must follow the complete manufacturer's instructions, including restrictions on energised connection or disconnection, enclosure requirements, approved wiring practices, ambient temperature and the maximum permitted load current.

Typical Applications

  • Industrial automation systems requiring hazardous-area-certified components.
  • PLC-to-field-equipment relay interfacing.
  • ATEX-rated electrical control panels, where the complete installation is compliant.
  • HazLoc Class I, Division 2 control applications within the approved conditions.
  • Industrial process control and monitoring.
  • Timed auxiliary control circuits.
  • Equipment sequencing and switching delays.
  • Multi-circuit signalling and alarm systems.
  • Electrical control interfaces in chemical processing environments.
  • OEM industrial control assemblies.
  • DIN-rail control panels requiring four changeover contacts.
  • Applications using a compatible 24 V DC control supply.

Technical Specifications

Tick the specs you need, then view products that match.

Terminal Type Screw
Switching Current (A) 6 A
Load Voltage 250 V AC
Mounting Type DIN rail
Manufacturer Finder
Manufacturer part number 58.34.9.024.0089SMA
Series 58 Series
Module type 58.34
Product category Hazardous-area electromechanical relay interface module
Nominal control voltage 24 V DC
Coil version DC
Contact configuration 4 CO / 4PDT
Number of poles 4
Number of changeover contacts 4
Contact material Silver nickel (AgNi)
Rated contact current 6 A, hazardous-area version
Maximum peak contact current 15 A
Rated contact voltage 250 V AC
Maximum switching voltage 250 V AC
Rated resistive switching capacity (AC1) 1,500 VA
Rated AC15 switching capacity at 230 V AC 350 VA
Single-phase motor rating at 230 V AC 0.24 kW
DC1 breaking capacity at 24 V DC 6 A
DC1 breaking capacity at 110 V DC 0.25 A
DC1 breaking capacity at 220 V DC 0.12 A
Minimum switching load 300 mW (5 V / 5 mA)
Relay mechanical life, DC coil 50 million cycles
Electrical life at rated AC1 load 150,000 cycles
Relay operate time Approximately 11 ms, excluding any timer delay
Relay release time Approximately 15 ms, excluding any timer delay
Coil-to-contact impulse withstand voltage 3.6 kV
Dielectric strength between open contacts 1,000 V AC
Dielectric strength between adjacent contacts 1,550 V AC
Environmental protection IP20
Mounting type 35 mm DIN rail
Terminal type Screw / box-clamp terminals
Terminal tightening torque 0.5 Nm
Wire stripping length 8 mm
Module width 27 mm
Mechanical indicator Fitted as part of the special 0089 configuration
Timing module Finder 86.30 timer configuration
ATEX / IECEx protection marking, product family II 3G Ex ec nC IIC Gc
HazLoc classification, product family Class I, Division 2, Groups A, B, C, D, T5
ATEX / IECEx ambient temperature range −40 to +70 °C for the relay interface family, subject to timer-module restrictions
HazLoc ambient temperature range −25 to +40 °C under the published family conditions
Ambient temperature range when fitted with Finder 86 modular timer −20 to +50 °C, subject to certification restrictions

Frequently Asked Questions

What is the Finder 58.34.9.024.0089SMA used for?

The Finder 58.34.9.024.0089SMA is a four-pole relay interface module intended for industrial automation, PLC interfacing and suitably designed hazardous-area control applications. Its special configuration includes a modular timing function and mechanical indication.

What control voltage does the Finder 58.34.9.024.0089SMA require?

The module is designated for a 24 V DC nominal control supply. The electrical characteristics of the relay and fitted timing module must be checked together before connection, including any polarity and supply restrictions.

How many contacts does the Finder 58.34.9.024.0089SMA have?

The module provides four changeover contacts (4 CO / 4PDT). Each pole includes common, normally open and normally closed connections, enabling four separate switching circuits to be operated through one interface assembly.

Is the Finder 58.34.9.024.0089SMA rated at 7 A?

No. Although the standard Finder 58.34 interface module is rated at 7 A, the hazardous-area version has a 6 A nominal contact rating. Lower limits apply under certain grouped ATEX/IECEx installations and HazLoc operating conditions. The applicable certified rating must be used.

What does the 0089SMA suffix indicate?

The 0089 configuration identifies a hazardous-area version with a Finder 86.30 modular timer option and a mechanical indicator. The SMA ordering suffix is associated with the screw-terminal interface assembly. The complete assembly's certification and timer functions should be confirmed using Finder's current product documentation.

Designed for Industrial Automation and Hazardous-Area Electrical Engineering

The Finder 58.34.9.024.0089SMA combines a 24 V DC relay interface, four changeover contacts, DIN-rail installation, screw-terminal wiring and specialist hazardous-area configuration. Its modular timing capability makes it a practical choice for engineered control systems where switching, sequencing and applicable ATEX/IECEx or HazLoc requirements must be considered together.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Priority sourcing and supply support

 Flexible payment terms for qualifying organisations

 Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...