Why Choose the Finder 090.06 6-Way Jumper Link?
The Finder 090.06 is a 6-way jumper link for relay sockets, designed to simplify electrical connections between adjacent Finder 90.02 and 90.03 screw terminal sockets. As part of the Finder 90 Series relay socket accessory range, this blue insulated connection bridge provides a convenient way to distribute a common electrical connection across multiple relay socket positions.
Rated at 10 A and 250 V, the Finder 090.06 is suitable for connecting the corresponding coil supply terminals of up to six compatible relay sockets. Its comb-style arrangement reduces the need for individual interconnecting wires, helping create more organised control panel wiring and simplifying assembly in installations containing several adjacent relays.
Designed for use with relay sockets associated with the Finder 60 Series industrial relay range, the Finder 090.06 is particularly useful in industrial automation, machinery control and electrical distribution applications. Its blue insulated construction and dedicated pin-type connections provide a practical solution for commoning compatible relay socket terminals while maintaining a tidy panel layout.
Key Advantages
- Dedicated 6-way jumper link for Finder 90.02 and 90.03 relay sockets.
- Allows a common electrical connection to be distributed across up to six adjacent sockets.
- 10 A continuous current rating for compatible control circuit applications.
- 250 V maximum rated operating voltage.
- Reduces the need for separate interconnecting wires between relay socket terminals.
- Supports neat, organised wiring in industrial control panels.
- Blue insulated construction for the standard blue Finder 90 Series socket arrangement.
- Pin-type connection design enables direct installation into compatible socket terminals.
- Helps simplify repetitive wiring during control panel manufacture.
- Suitable for maintenance, panel extensions and OEM electrical equipment assembly.
Key Features
- Finder 90 Series relay socket accessory.
- 6-way comb-style electrical jumper.
- Designed specifically for Finder 90.02 and 90.03 sockets.
- Connects corresponding coil supply terminals across compatible adjacent sockets.
- Rated current: 10 A.
- Rated operating voltage: 250 V.
- Maximum number of connected sockets: 6.
- Blue insulated body.
- Pin-type electrical connections.
- Single-pole common connection arrangement.
- Suitable for socket assemblies mounted on standard DIN rail or panels.
- Dedicated accessory for relay socket wiring rather than a standalone terminal block.
- RoHS-compliant construction.
- EAN: 8012823285931.
Simplified Electrical Connections for Multiple Relay Sockets
Industrial electrical control panels frequently contain several relays operating from a common control supply. Where multiple relay sockets require the same electrical connection, installers can either wire each socket individually or use a compatible jumper system to distribute the connection between adjacent positions.
The Finder 090.06 6-way jumper link is designed for this purpose. It provides a common conductive connection across up to six compatible Finder 90.02 and 90.03 screw terminal relay sockets, reducing the number of individual wires required for repetitive connections.
The jumper is particularly useful when connecting corresponding A1 or A2 coil supply terminals across a group of compatible sockets. This allows a shared supply connection to be distributed through a single bridging accessory, provided the total current and voltage remain within the specified ratings.
The Finder 90.02 socket is designed for the Finder 60.12 industrial relay, while the Finder 90.03 socket is designed for the Finder 60.13 industrial relay. Both sockets support panel mounting or installation on a standard 35 mm DIN rail conforming to EN 60715, making the jumper suitable for conventional industrial control panel arrangements.
The blue insulated construction corresponds to the standard blue Finder 90 Series socket configuration. Finder also offers the 090.06.0 black version for applications requiring the corresponding black accessory.
When installed correctly, the Finder 090.06 can help improve wiring consistency and reduce assembly time. It is especially useful in OEM panel production, machinery control systems and automation cabinets where groups of relays share a common control circuit connection.
The Finder 090.06 is a passive electrical connection accessory rather than a relay or switching device. It does not provide independent circuit protection, electrical isolation or switching functionality. Installers must ensure that the bridged terminals are intended to share the same electrical potential and that the complete circuit remains within the jumper's 10 A and 250 V ratings.
Typical Applications
- Commoning coil supply terminals across Finder 90.02 and 90.03 relay sockets.
- Industrial electrical control panel wiring.
- Relay interface assemblies and automation cabinets.
- PLC-controlled relay switching systems.
- Industrial machinery and equipment control circuits.
- Manufacturing and production line automation.
- Electrical distribution and auxiliary control circuits.
- OEM control panel manufacturing and assembly.
- Building automation and HVAC control panels.
- Process control and industrial signalling equipment.
- Maintenance and modification of existing Finder relay installations.
- Control systems requiring a shared electrical connection across multiple adjacent relay sockets.