Finder 7S.63.9.024.0211 - 7S Series Relay modules with forcibly guided contacts

Finder 7S.63.9.024.0211 – 7S Series Relay modules with forcibly guided contacts

Finder 7S.63.9.024.0211 is a 24 V DC force-guided safety relay module featuring 2 normally open safety contacts, 1 normally closed feedback contact, an additional auxiliary signalling contact, a 6 A contact rating, 250 V AC nominal switching voltage, screw terminals, LED status indication and DIN rail mounting for industrial safety-related control applications.

SKU: 7S.63.9.024.0211Alt SKU: 7S6390240211MPN: 7S.63.9.024.0211
Price
List Price £101.51 ex VAT
Your Price (ex VAT)
£101.51
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

SUBTOTAL (EX VAT) £101.51
Trade pricing is personalised to your account

Manufacturer Lead Time

£101.51

Why Choose the Finder 7S.63.9.024.0211 Force-Guided Safety Relay?

The Finder 7S.63.9.024.0211 is a professional 24 V DC force-guided safety relay module designed for industrial machinery, automation equipment and safety-related electrical control systems. Part of the Finder 7S Series, this specialised relay provides 2 normally open (NO) safety contacts, 1 normally closed (NC) feedback contact and 1 auxiliary signalling contact, combining monitored switching and supplementary status indication within a compact DIN rail-mounted assembly.

Featuring a 6 A rated contact current, 250 V AC nominal switching voltage and 24 V DC operating coil, the Finder 7S.63.9.024.0211 incorporates mechanically linked contacts designed to support fault detection in appropriately engineered safety systems. Its force-guided contact construction helps external monitoring equipment identify certain failures, including welded contacts, by maintaining a defined mechanical relationship between the normally open and normally closed safety contacts.

The relay is particularly suitable for dual-channel safety control architectures and applications requiring monitored switching. The 7S.63 family is designed for integration into safety-related systems with demanding functional safety requirements, including appropriately engineered SIL 3 and PL e applications. The achieved safety classification depends on the complete system architecture, diagnostic coverage and validation rather than the relay alone.

With screw-terminal connections, an integrated LED coil-status indicator, 22.5 mm housing width and standard 35 mm DIN rail mounting, the Finder 7S.63.9.024.0211 offers a practical solution for professional industrial control panels. Its IP20 protection and operating temperature range of −40 to +70 °C support reliable installation within suitably protected electrical enclosures.

Key Advantages

  • Force-guided safety contacts: Mechanically linked contacts support fault detection and monitored switching in safety-related control systems.
  • 2 NO + 1 NC safety contact configuration: Provides two normally open switching outputs and one normally closed feedback contact.
  • Additional auxiliary contact: Offers supplementary signalling functionality for compatible control and monitoring arrangements.
  • 24 V DC operating coil: Compatible with appropriately rated industrial control power supplies.
  • 6 A rated contacts: Suitable for switching compatible industrial control loads.
  • 250 V AC nominal switching voltage: Supports appropriately rated AC control circuits.
  • Functional safety integration: Designed for use in suitably engineered safety systems, including SIL 3 and PL e applications.
  • Dual-channel safety applications: Supports redundant switching arrangements where required by the safety architecture.
  • Contact-state feedback: Enables suitable monitoring equipment to detect certain contact failures.
  • Silver tin oxide and gold contact materials: Provide appropriate switching and signalling characteristics for industrial applications.
  • Screw-terminal connections: Provide secure and familiar wiring for control panel installation.
  • Integrated LED indication: Allows quick visual identification of coil energisation.
  • Compact 22.5 mm housing: Conserves space in densely populated electrical control cabinets.
  • 35 mm DIN rail mounting: Simplifies installation alongside safety controllers, contactors and PLC equipment.
  • Fast switching operation: Typical normally open contact operate and release times of 10 ms and 7 ms respectively.
  • High mechanical endurance: Designed for approximately 10 million mechanical operations.
  • Wide operating temperature range: Suitable for industrial environments between −40 and +70 °C.
  • IP20 protection: Intended for installation inside appropriately protected electrical enclosures.

Key Features

  • Finder 7S Series modular relay with force-guided contacts.
  • Product family: 7S.63.
  • Manufacturer part number: 7S.63.9.024.0211.
  • Electromagnetic, non-latching relay operation.
  • 2 normally open safety contacts.
  • 1 normally closed feedback contact.
  • 1 additional auxiliary signalling contact.
  • Class A force-guided contact technology.
  • Nominal coil voltage: 24 V DC.
  • Nominal coil current: 60 mA.
  • Nominal coil power: approximately 1.45 W.
  • Coil resistance: approximately 400 Ω.
  • Must-operate voltage: 20.4 V DC.
  • Must-release voltage: 2.4 V DC.
  • Rated contact current: 6 A.
  • Nominal switching voltage: 250 V AC.
  • Rated switching capacity: 1.5 kVA.
  • Silver tin oxide, silver nickel and gold contact materials.
  • Typical normally open contact operate time: 10 ms.
  • Typical normally open contact release time: 7 ms.
  • Mechanical endurance: approximately 10 million operations.
  • Electrical endurance: approximately 100,000 operations under specified conditions.
  • Integrated LED coil-status indicator.
  • Screw-terminal electrical connections.
  • Standard 35 mm DIN rail mounting.
  • Compact 22.5 mm housing width.
  • IP20 ingress protection.
  • Operating temperature range: −40 to +70 °C.
  • Force-guided contact design associated with EN 61810-3.
  • Suitable for properly engineered safety-related control systems.

Technical Specifications

  • Manufacturer: Finder
  • Series: 7S Series
  • Product family: 7S.63
  • Model: 7S.63.9.024.0211
  • Manufacturer part number: 7S.63.9.024.0211
  • Alternative reference: 7S6390240211
  • Product type: Modular force-guided safety relay
  • Relay technology: Electromagnetic
  • Relay operation: Non-latching
  • Safety contact configuration: 2 NO + 1 NC
  • Normally open safety contacts: 2
  • Normally closed feedback contacts: 1
  • Additional auxiliary signalling contacts: 1
  • Contact technology: Class A force-guided, mechanically linked
  • Contact materials: Silver tin oxide (AgSnO₂), silver nickel (AgNi) and gold (Au)
  • Rated contact current: 6 A
  • Nominal switching voltage: 250 V AC
  • Rated insulation voltage: 250 V
  • Rated switching capacity: 1.5 kVA
  • Nominal coil voltage: 24 V DC
  • Nominal coil current: 60 mA
  • Nominal coil power: 1.45 W
  • Coil resistance: 400 Ω
  • Must-operate voltage: 20.4 V DC
  • Must-release voltage: 2.4 V DC
  • Typical NO contact operate time: 10 ms
  • Typical NO contact release time: 7 ms
  • Mechanical endurance: 10,000,000 operations
  • Electrical endurance: 100,000 operations under specified conditions
  • Terminal type: Screw terminals
  • Mounting: 35 mm DIN rail
  • Housing width: 22.5 mm
  • Housing height: 86.2 mm
  • Housing depth: 100.3 mm
  • Ingress protection: IP20
  • Operating temperature: −40 to +70 °C
  • Pollution degree: 2
  • Status indication: Integrated LED
  • Relevant force-guided contact standard: EN 61810-3
  • Safety application: Suitable for appropriately engineered SIL 3 / PL e systems
  • RoHS compliance: Compliant
  • EAN / GTIN-13: 8012823421193
  • Country of origin: Italy

Reliable Force-Guided Switching for Industrial Safety Systems

Industrial machinery and automated production equipment frequently require electrical control systems that can switch multiple circuits while detecting faults capable of compromising a safety function. In these applications, a welded contact or an undetected switching failure can prevent machinery from responding as intended. The Finder 7S.63.9.024.0211 addresses these requirements through its force-guided contact construction and dedicated feedback functionality.

The relay provides two normally open safety contacts for switching compatible circuits and one normally closed feedback contact for monitoring the switching state. The force-guided mechanical linkage is designed to prevent specified normally open and normally closed contacts from being closed simultaneously, even under certain contact-welding conditions. This enables an appropriately designed external monitoring circuit to detect selected relay faults before the machinery is permitted to restart.

An additional auxiliary signalling contact provides further flexibility for status indication and control-system integration. The auxiliary contact must be used according to the manufacturer's connection diagram and applicable electrical ratings; its presence does not automatically make it an additional safety-rated switching output.

The 24 V DC coil is compatible with common industrial control supplies. Its nominal 60 mA coil current, approximately 1.45 W coil power and 400 Ω coil resistance support predictable electromagnetic operation. The specified must-operate voltage of 20.4 V DC and must-release voltage of 2.4 V DC provide useful parameters for control circuit design.

The relay's 6 A contact rating, 250 V AC nominal switching voltage and 1.5 kVA rated switching capacity support a variety of industrial control loads. The actual permissible load depends on the utilisation category, switching frequency, inrush current and operating conditions. Designers should consider contact protection and appropriate upstream circuit protection where required.

With typical normally open contact operate and release times of 10 ms and 7 ms, the Finder 7S.63.9.024.0211 provides responsive switching. Its specified mechanical endurance of approximately 10 million operations supports repeated operation in industrial control environments. Electrical endurance depends on the connected load and switching conditions.

The relay's screw terminals provide secure connections for industrial panel wiring, while its integrated LED gives local visual confirmation of coil energisation. The compact 22.5 mm DIN rail housing allows convenient integration alongside safety controllers, PLCs, contactors and monitoring equipment.

Functional safety consideration: The Finder 7S.63.9.024.0211 is suitable for incorporation into properly engineered safety-related systems, including architectures targeting SIL 3 or PL e. However, the relay alone does not establish the safety integrity of the complete machine. The final safety classification depends on the architecture, redundancy, diagnostic coverage, reliability calculations, common-cause failure measures and validation of the complete safety function.

Typical Applications

  • Industrial machinery safety: Force-guided switching in professionally engineered safety-related control systems.
  • Emergency-stop systems: Switching and feedback monitoring in suitable emergency-stop architectures.
  • Machine guard interlocking: Contact-state feedback in compatible guard monitoring circuits.
  • Dual-channel safety systems: Integration into redundant safety control arrangements.
  • Safety PLC installations: Relay switching and external device monitoring alongside compatible safety controllers.
  • Industrial automation: Monitored switching in automated manufacturing equipment.
  • 24 V DC control systems: Integration into common industrial low-voltage control installations.
  • Conveyor systems: Safety-related switching and feedback monitoring in material-handling equipment.
  • Packaging machinery: Relay switching in suitable machine safety assemblies.
  • Automated warehouses: Monitored control functions in storage and retrieval systems.
  • Hoists and cranes: Compatible switching and monitoring functions in lifting equipment controls.
  • Lift and escalator systems: Force-guided relay applications in properly engineered control systems.
  • Woodworking machinery: Monitored electrical switching within suitable machinery safety systems.
  • Industrial process control: Relay switching with contact-state feedback.
  • Chemical and petrochemical facilities: Integration into suitable industrial control architectures.
  • Automated car wash systems: Switching and monitoring in machinery control equipment.
  • Safety control cabinets: Compact DIN rail-mounted relay modules with feedback contacts.
  • Machine refurbishment: Replacement of compatible Finder 7S.63 force-guided relay modules.

Frequently Asked Questions

What is the Finder 7S.63.9.024.0211 used for?

The Finder 7S.63.9.024.0211 is a force-guided safety relay module designed for industrial automation and safety-related control applications requiring monitored switching, mechanically linked contacts and auxiliary signalling.

What is the coil voltage of the Finder 7S.63.9.024.0211?

The relay has a 24 V DC coil, with a nominal current of approximately 60 mA and coil power of approximately 1.45 W.

How many contacts does this relay have?

The Finder 7S.63.9.024.0211 provides 2 normally open safety contacts, 1 normally closed feedback contact and 1 additional auxiliary signalling contact.

What is the purpose of the auxiliary signalling contact?

The auxiliary contact provides an additional signalling function for compatible monitoring and control arrangements. Its electrical role and permitted use must be checked against the manufacturer's wiring diagram.

What are force-guided relay contacts?

Force-guided contacts are mechanically linked normally open and normally closed contacts designed to prevent simultaneous closure under specified fault conditions. This allows suitable external monitoring circuits to detect certain relay failures, including welded contacts.

What is the rated contact current?

The relay has a 6 A rated contact current. The permissible switching load depends on the electrical load type, operating voltage and manufacturer's specified ratings.

What is the nominal AC switching voltage?

The Finder 7S.63.9.024.0211 has a 250 V AC nominal switching voltage, subject to the applicable switching current and load limitations.

Can the Finder 7S.63.9.024.0211 be used in SIL 3 safety systems?

Yes. The Finder 7S.63 family is designed for integration into appropriately engineered safety-related systems, including applications targeting SIL 3. The complete system must satisfy the applicable functional safety requirements.

Can this relay be used in systems targeting Performance Level e?

Yes. The relay can be incorporated into suitably engineered systems targeting PL e, provided the complete safety architecture, diagnostic coverage, component reliability and validation satisfy the relevant requirements.

Does the relay independently provide SIL 3 or PL e for an entire safety function?

No. A force-guided relay is one component within a safety-related control system. The achieved SIL or Performance Level depends on the complete system design, reliability calculations, fault monitoring and validation.

What type of terminals does the Finder 7S.63.9.024.0211 use?

The relay uses screw terminals, providing conventional electrical connections for industrial control panel wiring.

Does the relay include an LED status indicator?

Yes. The Finder 7S.63.9.024.0211 includes an integrated LED indicator that provides visual indication of coil energisation.

What are the coil current and resistance?

The relay has a nominal coil current of approximately 60 mA and a coil resistance of approximately 400 Ω at its rated 24 V DC supply.

What are the relay operating and release times?

The normally open contacts have typical operate and release times of approximately 10 ms and 7 ms respectively, under specified operating conditions.

How is the Finder 7S.63.9.024.0211 mounted?

The relay is designed for installation on a standard 35 mm DIN rail inside a suitable electrical control enclosure.

What are the dimensions of the relay?

The Finder 7S.63.9.024.0211 measures approximately 22.5 mm wide, 86.2 mm high and 100.3 mm deep.

What is the operating temperature range?

The relay has an operating temperature range of −40 to +70 °C, making it suitable for a wide range of protected industrial control environments.

What is the difference between the Finder 7S.63.9.024.0211 and 7S.63.9.012.0211?

The 7S.63.9.024.0211 uses a 24 V DC coil, whereas the 7S.63.9.012.0211 uses a 12 V DC coil. Both belong to the Finder 7S.63 family and offer 2 NO + 1 NC safety contacts with an additional auxiliary contact, but the coil voltage must match the control supply.

What is the difference between the Finder 7S.63 and 7S.43 relay families?

Both families provide force-guided safety relay configurations with auxiliary signalling functionality. The 7S.63 family uses screw-terminal connections, whereas the 7S.43 family uses screwless terminals. Always check the complete part number and wiring arrangement before substitution.

Can the Finder 7S.63.9.024.0211 be used in emergency-stop circuits?

Yes. The relay can form part of a properly engineered emergency-stop system where its contact arrangement, switching ratings and feedback monitoring characteristics meet the application's requirements. It is not a complete emergency-stop controller on its own.

What should be checked before installing the Finder 7S.63.9.024.0211?

Check the 24 V DC coil supply, 2 NO + 1 NC safety contact arrangement, auxiliary contact function, switching current, load voltage, safety monitoring requirements, screw-terminal wiring, environmental conditions and Finder's installation instructions.

Designed for Professional Industrial Safety and Automation

Finder 7S Series force-guided relays provide dependable switching and contact-state monitoring capabilities for industrial automation and safety-related electrical control systems. Combining a 24 V DC coil, 2 NO + 1 NC mechanically linked safety contacts, an additional auxiliary signalling contact, a 6 A contact rating, screw terminals, LED status indication and compact DIN rail construction, the Finder 7S.63.9.024.0211 offers a practical solution for professionally engineered machinery safety and monitoring applications.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Priority sourcing and supply support

 Flexible payment terms for qualifying organisations

 Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...