131F0342 Danfoss VLT FC-102 HVAC Drive 75 KW / 100 HP, 380 - 480 VAC, IP20

131F0342 Danfoss VLT FC-102 HVAC Drive 75 KW / 100 HP, 380 – 480 VAC, IP20

Danfoss 131F0342 VLT HVAC Drive FC-102, a 75 kW / 100 HP three phase 380-480 V AC variable frequency drive with IP20 chassis enclosure, RFI Class A1/B filter and graphical local control panel for HVAC fan, pump and building services motor control applications.

SKU: 131F0342Alt SKU: FC-102P75KT4E20H1XGXXXXSXXXXAXBXCXXXXDXMPN: 131F0342
Price
List Price £8,083.00 ex VAT
Your Price (ex VAT) Save 45%
£4,445.65 45% OFF
You save £3,637.35 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,445.65
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,445.65

Why Choose the Danfoss 131F0342 VLT HVAC Drive FC-102?

The Danfoss 131F0342 is a high-performance AC variable frequency drive (VFD) designed for reliable motor control in HVAC, building services and industrial ventilation applications. As part of the Danfoss VLT HVAC Drive FC-102 series, it is engineered for fans, pumps, compressors and heating, ventilation and air conditioning systems where energy efficiency and dependable performance are essential.

This drive provides dedicated HVAC functionality in a robust IP20 chassis format. The VLT HVAC Drive range is widely used in building automation systems because it helps optimise motor speed, reduce energy consumption and improve comfort control in ventilation, pumping and refrigeration applications.

With a rated output power of 75 kW / 100 HP, a 147 A continuous current rating and a three-phase 380–480 V AC supply, the 131F0342 is suitable for demanding HVAC motors used in fans, pumps and air handling equipment. Its built-in RFI Class A1/B filter supports electromagnetic compatibility in suitable installations, while the graphical local control panel provides convenient drive setup and monitoring.

Key Advantages

  • Dedicated VLT HVAC Drive for building services applications.
  • 75 kW / 100 HP motor power rating suitable for demanding HVAC fan and pump systems.
  • Three-phase 380–480 V AC input compatible with industrial supplies.
  • 147 A continuous current rating for dependable motor operation.
  • Built-in RFI Class A1/B filter for improved electromagnetic compatibility.
  • Supplied with graphical local control panel for easy commissioning.
  • Robust IP20 chassis design for panel and cabinet installation.

Key Features

  • Danfoss VLT HVAC Drive FC-102 series.
  • 75 kW / 100 HP rated output power.
  • 147 A continuous output current.
  • Three-phase 380–480 V AC input supply.
  • IP20 / chassis enclosure format.
  • Built-in RFI Class A1/B / C1 filter.
  • No brake chopper fitted.
  • Graphical local control panel included.
  • Frame size C4.
  • Designed for HVAC fan, pump and compressor motor control.

Efficient Motor Control for HVAC Systems

Variable frequency drives such as the Danfoss VLT HVAC Drive FC-102 regulate motor speed by adjusting output voltage and frequency. In HVAC systems, this allows fans, pumps and compressors to operate only at the speed required, helping reduce energy use and improve overall system performance.

The 131F0342 is designed for control panel installations in building services, plant rooms and industrial HVAC systems. Its HVAC-focused functionality makes it suitable for applications where reliable motor control, efficient operation and smooth speed regulation are important.

Typical Applications

  • HVAC fans and air handling units.
  • Building services pumps and circulation systems.
  • Ventilation and extraction equipment.
  • Heating and cooling plant room systems.
  • Industrial fan and pump applications.
  • Control panels and building automation installations.

Technical Specifications

Tick the specs you need, then view products that match.

Power 75 kW
Voltage 480 V
Phase Three Phase
IP Rating IP20
EMC Filter Commercial
Series VLT HVAC Drive FC-102
Part number 131F0342
Product type AC variable frequency drive
Rated output power 75 kW / 100 HP
Continuous current 147 A at 380–440 V AC / 130 A at 441–480 V AC
Intermittent current 162 A at 380–440 V AC / 143 A at 441–480 V AC
Input voltage 380–480 V AC
Input phases 3-phase
Output phases 3-phase
Output frequency 0–1000 Hz
Supply frequency 50 / 60 Hz
Protection rating IP20 / chassis
Frame size C4
RFI filter Class A1/B / C1
Brake chopper Not included
Local control panel Graphical local control panel included
Dimensions (H × W × D) approx. 660 × 370 × 333 mm
Weight approx. 49.89 kg

Frequently Asked Questions

What is the Danfoss 131F0342 used for?

The Danfoss 131F0342 is used to control three-phase AC motors in HVAC, fan, pump, ventilation and building services applications.

What motor power is supported by this drive?

This VLT HVAC Drive FC-102 is rated for motors with an output power of approximately 75 kW / 100 HP.

What supply voltage does the Danfoss 131F0342 require?

The drive operates from a three-phase 380–480 V AC supply.

Does this drive include a brake chopper?

No, the Danfoss 131F0342 configuration does not include a brake chopper.

Does the drive include a local control panel?

Yes, this configuration includes a graphical local control panel for drive setup, monitoring and operation.

Trusted by HVAC and Building Services Engineers

Danfoss VLT HVAC Drive FC-102 inverters are trusted by building services engineers, panel builders, facilities teams and maintenance engineers for efficient motor control, reliable operation and long-term performance in HVAC applications.