ABB EPH-S17208 Protecta Home eight-way dual-RCD split-load consumer unit with 100 A main switch isolator, one 80 A RCCB and one 63 A RCCB. Nominal dimensions 250 × 330 × 105 mm. ABB order code 1TVC151800S3070.

SKU: 1TVC151800S3070Alt SKU: EPH-S17208MPN: 1TVC151800S3070
Price
List Price £356.14 ex VAT
Your Price (ex VAT)
£356.14
Manufacturer Lead Time Estimated Delivery 4 weeks
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

SUBTOTAL (EX VAT) £356.14
Trade pricing is personalised to your account

Manufacturer Lead Time

£356.14

Why Choose the ABB EPH-S17208 Protecta Home 8-Way 100A Dual RCD Consumer Unit?

The ABB EPH-S17208 (ABB order code 1TVC151800S3070) is an 8-way, 100 A split-load consumer unit from the ABB Protecta Home range. Designed for low-voltage electrical distribution, this consumer unit combines a 100 A main switch isolator with two residual current devices (RCDs), rated at 80 A and 63 A respectively. This configuration provides a practical solution for suitable residential electrical installations requiring two RCD-protected circuit groups.

Identified by ABB as EPH-S17208 8W 100A ISO 1x80A+63A RC, the unit provides eight outgoing ways within a coordinated split-load arrangement. The two RCDs allow outgoing circuits to be divided between separately protected sections, with the exact allocation determined by the approved consumer unit configuration and installation requirements.

The EPH-S17208 features nominal enclosure dimensions of 250 × 330 × 105 mm (H × W × D), as listed in ABB's Protecta Home consumer unit selection guide. The compact format makes it suitable for installations where eight outgoing ways are sufficient and a larger distribution board would be unnecessary.

With a 100 A incoming isolator, an 80 A RCCB and a 63 A RCCB, the ABB EPH-S17208 offers a defined dual-RCD configuration for professional electrical installers. The main switch provides incoming isolation, while the RCCBs provide residual current protection to their associated outgoing circuit groups. Appropriate overcurrent protection must be provided separately for the final circuits.

Key Advantages

  • Eight outgoing ways provide capacity for a compact multi-circuit distribution arrangement.
  • 100 A main switch isolator provides a dedicated incoming isolation function.
  • 80 A RCCB provides residual current protection for one circuit group.
  • 63 A RCCB provides residual current protection for a second circuit group.
  • Dual-RCD split-load configuration supports planned separation of outgoing circuits.
  • Different RCCB current ratings allow the installer to work with the manufacturer's specified 80 A and 63 A arrangement.
  • Compact 330 mm nominal width makes the enclosure suitable for smaller distribution installations.
  • 250 mm nominal height supports a space-efficient enclosure format.
  • 105 mm nominal depth assists wall-mounting and cable-routing planning.
  • ABB Protecta Home design provides a coordinated electrical distribution solution.
  • Separate incoming isolation and residual current protection provide clearly defined electrical functions.
  • Suitable for compatible outgoing MCB arrangements selected to match the installation design.
  • Part of ABB's wider Protecta Home range with alternative capacities and RCD configurations.
  • Practical for residential refurbishment and new electrical installations.
  • Manufacturer order code 1TVC151800S3070 supports accurate product identification and specification.

Key Features

  • ABB EPH-S17208 Protecta Home consumer unit.
  • Eight outgoing ways.
  • 100 A incoming main switch isolator.
  • One 80 A RCCB.
  • One 63 A RCCB.
  • Dual-RCD split-load arrangement.
  • Two separately RCD-protected circuit sections.
  • 250 mm nominal enclosure height.
  • 330 mm nominal enclosure width.
  • 105 mm nominal enclosure depth.
  • Compact single-row consumer unit format.
  • Incoming supply isolation through the main switch.
  • Residual current protection through the two RCCBs.
  • Compatible outgoing protective device accommodation.
  • ABB Protecta Home product family.
  • Suitable for professional electrical installation.
  • Manufacturer model EPH-S17208.
  • ABB order code 1TVC151800S3070.
  • Manufacturer designation 8W 100A ISO 1x80A+63A RC.

100A Main Switch with 80A and 63A RCCB Protection

The ABB EPH-S17208 is designed around a specific combination of electrical devices: a 100 A incoming isolator, an 80 A RCCB and a 63 A RCCB. This differs from Protecta Home consumer units fitted with two identically rated RCCBs and provides an alternative arrangement for projects requiring the manufacturer's mixed-rating dual-RCD configuration.

The 100 A main switch provides the incoming isolation function for the consumer unit. It is used to disconnect the supply to the assembly when appropriate. The switch's rated current must not be confused with the permissible load of the individual outgoing circuits or the rated current of either RCCB.

The 80 A RCCB provides residual current protection for one section of the consumer unit. Its 80 A rating represents the device's rated current-carrying capacity, subject to its installation conditions and coordination. It does not describe the amount of earth leakage required to operate the device.

The 63 A RCCB provides corresponding residual current protection for the other section. The two RCCBs have different rated currents, so the installer must ensure that the proposed circuit allocation, upstream protection and expected loading are appropriate for each device.

ABB's Protecta Home selection guide notes that RCCB split consumer units have a variable split arrangement. The precise allocation of the eight outgoing ways between the two RCCBs should therefore be confirmed against the supplied assembly and manufacturer's installation instructions rather than assuming a fixed four-way/four-way division.

Although the consumer unit provides two RCD-protected sections, an earth leakage fault on a circuit may disconnect other circuits supplied through the same RCCB. Where a design requires more individualised fault protection or improved continuity of supply, the electrician should consider whether a compatible RCBO-based arrangement is more appropriate.

The RCCBs do not replace outgoing overcurrent protective devices. Suitable MCBs or other approved protective devices must be provided for overload and short-circuit protection. The selected equipment must be compatible with the ABB busbar system, enclosure arrangement and completed assembly specification.

The nominal enclosure dimensions of 250 × 330 × 105 mm should be considered during installation planning. Sufficient space must be allowed for mounting, conductor routing, cable entry, access to protective devices and the safe operation of the main switch and RCCBs.

Installation, inspection and commissioning must be undertaken by a competent electrical professional in accordance with ABB's instructions and applicable requirements of BS 7671. The installer must confirm RCCB sensitivity and type, circuit grouping, neutral conductor separation, device compatibility, earthing arrangements and final electrical test results.

Typical Applications

  • Residential electrical distribution installations requiring eight outgoing ways.
  • Domestic split-load consumer unit replacement projects.
  • Electrical refurbishment involving two RCCB-protected circuit groups.
  • New-build residential electrical installations.
  • Compact multi-circuit domestic distribution.
  • Installations requiring a 100 A incoming main switch.
  • Projects specifying an 80 A and 63 A RCCB combination.
  • Residential electrical installation upgrades.
  • Professional electrical contracting projects.
  • Suitable indoor electrical service areas.
  • Low-voltage final-circuit distribution assemblies.
  • Projects requiring planned separation of outgoing circuits between two RCCBs.
  • Replacement of appropriately specified dual-RCD consumer units.
  • Installations using compatible ABB outgoing protective devices.
  • Projects specifying the ABB Protecta Home consumer unit range.

Technical Specifications

Tick the specs you need, then view products that match.

Material Steel
Product Series ABB Protecta Home
Device Type Consumer Unit
Incomer Main switch / isolator + RCCB
Number of Outgoing Ways 8
Current 100 A
Brand ABB
Product group Protecta Home
Product range Protecta Home
ABB order code 1TVC151800S3070
Manufacturer designation EPH-S17208 8W 100A ISO 1x80A+63A RC
Product type Dual-RCD split-load consumer unit
Consumer unit configuration Main switch with two RCCBs
Number of outgoing ways 8
Incoming isolation device Main switch isolator
Main switch rated current 100 A
Number of RCCBs 2
First RCCB rated current 80 A
Second RCCB rated current 63 A
RCCB arrangement 1 × 80 A + 1 × 63 A
Number of RCD-protected sections 2
Nominal height 250 mm
Nominal width 330 mm
Nominal depth 105 mm
Nominal dimensions (H × W × D) 250 × 330 × 105 mm
Dimensional reference ABB Protecta Home consumer unit selection guide
RCCB rated residual operating current (IΔn) Confirm against the fitted devices and ABB documentation
RCCB type Confirm against the fitted devices and ABB documentation
RCCB pole configuration Confirm against the fitted device specification
RCCB current ratings 80 A and 63 A
Incoming isolation function Provided by the 100 A main switch
Residual current protection Provided by the two RCCBs
Outgoing circuit overcurrent protection Requires suitable compatible protective devices
Outgoing circuit arrangement Subject to ABB's approved split-load configuration
Split arrangement Variable, subject to ABB's instructions
Enclosure material Steel, as specified for the Protecta Home consumer unit family
Enclosure finish RAL 7035 grey, as specified for the Protecta Home steel enclosure family
Busbar arrangement Confirm against the supplied assembly and ABB installation instructions
Neutral bar arrangement Must correspond to the separate RCCB-protected sections
Protective earth bar arrangement Confirm against the supplied assembly
Ingress protection Confirm against the exact product documentation
Mechanical impact resistance Confirm against the exact product documentation
Electrical application Low-voltage final-circuit distribution
Installation environment Suitable indoor electrical distribution locations
Relevant assembly standard BS EN 61439-3, as applicable to the completed assembly
Installation requirements BS 7671 and ABB manufacturer instructions
Professional installation Required

Frequently Asked Questions

What is the ABB EPH-S17208 used for?

The ABB EPH-S17208 is an eight-way Protecta Home split-load consumer unit with a 100 A main switch isolator, one 80 A RCCB and one 63 A RCCB. It is intended for suitable low-voltage electrical distribution installations.

What is the ABB order code for the EPH-S17208?

The ABB manufacturer order code is 1TVC151800S3070. The model designation is EPH-S17208.

How many outgoing ways does the ABB EPH-S17208 have?

The ABB EPH-S17208 provides eight outgoing ways. The distribution of these ways between the two RCCB-protected sections must follow ABB's approved split-load arrangement.

What is the rating of the ABB EPH-S17208 main switch?

The consumer unit is specified with a 100 A incoming main switch isolator. This provides the incoming isolation function for the assembly.

How many RCCBs does the ABB EPH-S17208 include?

The ABB EPH-S17208 is specified with two RCCBs: one rated at 80 A and one rated at 63 A.

What does 8W 100A ISO 1x80A+63A RC mean?

The designation identifies an eight-way consumer unit with a 100 A main switch isolator, one 80 A RCCB and one 63 A RCCB.

Is the ABB EPH-S17208 a split-load consumer unit?

Yes. The EPH-S17208 is a dual-RCD split-load consumer unit designed to accommodate outgoing circuits across two separately RCCB-protected sections.

What are the dimensions of the ABB EPH-S17208?

ABB lists nominal dimensions of 250 × 330 × 105 mm (height × width × depth) for the EPH-S17208 in its Protecta Home consumer unit selection guide.

Why does the ABB EPH-S17208 have an 80A RCCB and a 63A RCCB?

The EPH-S17208 uses ABB's specified mixed-rating dual-RCCB arrangement. The suitability of each section depends on its expected loading, upstream protection and the approved circuit distribution. The two current ratings do not establish the residual operating sensitivity of either RCCB.

Does an 80A RCCB trip at 80A of earth leakage?

No. 80 A is the RCCB's rated current, not its residual operating sensitivity. The rated residual operating current is expressed in milliamps and must be verified against the fitted device markings.

Does the ABB EPH-S17208 provide overcurrent protection?

The main switch and RCCBs do not independently provide outgoing circuit overload or short-circuit protection. Suitable compatible protective devices must be incorporated into the completed electrical installation.

Can MCBs be fitted to the ABB EPH-S17208?

The EPH-S17208 is intended for use with compatible outgoing circuit protective devices. Any MCBs must be suitable for the ABB enclosure and busbar system and correctly selected for their circuits.

Can the eight ways be divided equally between the two RCCBs?

ABB notes that its RCCB split consumer units have a variable split arrangement. An equal division should not be assumed without checking the specific supplied assembly and manufacturer's installation instructions.

What happens if one RCCB trips?

If one RCCB operates, it disconnects the circuits supplied through its protected section. Circuits supplied through the other RCCB may remain energised, provided no other protective device operates and the installation is correctly arranged.

What is the difference between the ABB EPH-S17208 and EPH-S16208?

Both are eight-way Protecta Home consumer units with a 100 A main switch and two RCCBs. The EPH-S17208 has one 80 A and one 63 A RCCB, whereas the EPH-S16208 has two 63 A RCCBs.

What is the difference between the ABB EPH-S17208 and EPH-S17212?

Both models specify a 100 A main switch with one 80 A RCCB and one 63 A RCCB. The EPH-S17208 provides eight ways, while the EPH-S17212 provides twelve ways.

Designed for Professional Electricians and Dual-RCD Residential Distribution

The ABB EPH-S17208 Protecta Home consumer unit combines eight outgoing ways with a 100 A incoming isolator, one 80 A RCCB and one 63 A RCCB. With nominal dimensions of 250 × 330 × 105 mm, it provides a compact, coordinated dual-RCD solution for professionally designed residential electrical distribution installations.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Priority sourcing and supply support

 Flexible payment terms for qualifying organisations

 Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...