Why Choose the ABB EPX-ICMETER800MID 800A Incomer Metering Kit?
The ABB EPX-ICMETER800MID is a dedicated 800 A incoming supply metering kit with an MID-designated energy meter, developed for compatible ABB Protecta Power electrical distribution assemblies. Part of the ABB Protecta Power Enclosures product group, this kit provides a coordinated solution for monitoring electrical energy consumption at the incoming supply of a low-voltage distribution panelboard. Its ABB order code is 1TVS151800S3357.
The EPX-ICMETER800MID incorporates ABB M4M energy metering technology with pulse output, Modbus communication and an MID-designated meter. It is intended for electrical distribution projects where incoming energy measurement, communication with compatible monitoring systems and appropriate metering certification are important considerations.
Unlike outgoing metering kits that require a separately specified side extension chamber, the EPX-ICMETER800MID includes a top/bottom extension box alongside the meter, fixing brackets, current transformers and terminals. ABB specifies a nominal extension enclosure size of 300 × 1000 mm (H × W). This integrated arrangement supports the installation of incoming energy monitoring equipment within compatible Protecta Power distribution systems.
Key Advantages
- Purpose-designed 800 A incomer metering kit for ABB Protecta Power electrical distribution systems.
- Includes an MID-designated ABB M4M energy meter for applications requiring appropriately certified measurement equipment.
- Supports pulse output and Modbus communication for integration with compatible energy monitoring systems.
- Supplied with a top/bottom extension box for coordinated enclosure integration.
- Includes the meter, fixing brackets, current transformers and terminals.
- 300 × 1000 mm nominal extension enclosure dimensions for compatible installation arrangements.
- Enables incoming supply energy consumption monitoring within low-voltage distribution assemblies.
- Supports electrical energy management, consumption analysis and operational reporting.
- Part of the coordinated ABB Protecta Power Enclosures accessory range.
- Suitable for commercial and industrial electrical distribution projects.
- Identified by ABB order code 1TVS151800S3357 for accurate specification and ordering.
Key Features
- ABB Protecta Power Enclosures product family.
- EPX-ICMETER800MID incoming metering kit.
- 800 A nominal incomer metering application.
- ABB M4M energy metering technology.
- MID-designated metering variant.
- Pulse output for compatible energy monitoring equipment.
- Modbus communication for integration with suitable monitoring systems.
- Includes a top/bottom extension enclosure.
- 300 mm nominal enclosure height.
- 1000 mm nominal enclosure width.
- Supplied with the energy meter and associated fixing brackets.
- Includes current transformers for the specified incoming measurement arrangement.
- Includes terminals for the metering kit installation.
- Designed for incoming supply monitoring rather than individual outgoing circuit metering.
- Intended for integration with compatible ABB Protecta Power distribution assemblies.
- Metering equipment rather than a circuit breaker or incoming switching device.
- Manufacturer model EPX-ICMETER800MID and ABB order code 1TVS151800S3357.
800A Incoming Energy Monitoring with MID Metering and Modbus Connectivity
The ABB Protecta Power system provides a modular platform for low-voltage electrical distribution in commercial and industrial installations. Incoming metering allows electrical energy consumption to be measured at the supply entering a distribution assembly, providing information that can support building energy management, operational monitoring and electrical consumption reporting.
The ABB EPX-ICMETER800MID is designed for an 800 A incomer metering arrangement and uses an MID-designated ABB M4M meter. The Measuring Instruments Directive (MID) establishes conformity requirements for specified measuring instruments, including applicable active electrical energy meters. Where measurement results are intended for regulated billing or other legally controlled purposes, the certification of the meter, the complete current transformer measurement arrangement and the applicable regulatory requirements must be verified.
The kit's pulse output supports energy data collection through compatible monitoring equipment, while Modbus communication provides a means of exchanging measurement information with suitable building management and energy monitoring systems. The precise measurement parameters, communication settings and connection requirements depend on the supplied ABB M4M meter and its technical documentation.
ABB specifies that its Protecta Power incomer metering kits include a top/bottom extension box, meter, fixing brackets, current transformers and terminals. For the EPX-ICMETER800MID, the extension enclosure has nominal dimensions of 300 × 1000 mm. This differs from ABB's outgoing metering kits, for which a compatible side extension enclosure with metering provision is ordered separately.
The Protecta Power range also includes the EPX-ICMETER800, a standard 800 A M4M pulse / Modbus incomer metering kit without the MID designation. Other MID-designated incoming metering options include the EPX-ICMETER250MID, EPX-ICMETER400MID and EPX-ICMETER630MID. Selection should be based on the intended incoming supply arrangement, compatible distribution assembly and project-specific metering requirements.
Typical Applications
- ABB Protecta Power 800 A incoming supply metering installations.
- Incoming electrical energy monitoring in compatible low-voltage distribution panelboards.
- Commercial building main distribution systems.
- Industrial electrical distribution and energy monitoring installations.
- Electrical switchrooms requiring integrated incomer metering.
- Building management systems using compatible Modbus communication.
- Energy monitoring systems incorporating pulse input equipment.
- Projects requiring an MID-designated incoming energy meter.
- Facilities management, energy consumption analysis and electrical performance reporting.
- Switchboard manufacturing and electrical panel building projects.
- Compatible Protecta Power distribution system upgrades and metering installations.