Why Choose the IMO B6CR1N06-30-A-110 Type A RCBO?
The IMO B6CR1N06-30-A-110 is a compact Type A Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed specifically for 110 V AC single-phase electrical systems. It combines overload, short-circuit and residual-current protection within a single DIN rail-mounted device, simplifying installation while providing comprehensive protection for personnel and equipment.
Its Type A residual-current characteristic detects both alternating sinusoidal residual currents and pulsating DC residual currents, making it suitable for modern electrical equipment incorporating electronic power supplies, control systems, LED lighting and other electronic loads.
Featuring a 6 A rated current, C curve tripping characteristic, 30 mA residual-current sensitivity, 110 V AC operating voltage and a 10 kA short-circuit breaking capacity, the B6CR1N06-30-A-110 is ideal for industrial sites, construction applications and temporary power systems operating at 110 V.
Key Advantages
- Provides combined overload, short-circuit and earth leakage protection.
- Type A residual-current detection for AC and pulsating DC leakage currents.
- C Curve characteristic suitable for moderate inrush current applications.
- 6 A rated current for low-current control and lighting circuits.
- 30 mA residual-current sensitivity enhances protection against electric shock.
- 10 kA breaking capacity provides high fault interruption capability.
- Designed specifically for 110 V AC electrical installations.
- Compact single-module DIN rail construction.
Key Features
- IMO B6 Series Type A RCBO.
- Rated current: 6 A.
- Rated voltage: 110 V AC.
- C Curve trip characteristic.
- 30 mA residual operating current.
- Type A residual-current protection.
- 10 kA breaking capacity.
- 1 Pole + Neutral (1P+N).
- Single-module 18 mm DIN rail mounting.
- Compatible with IMO MCB accessories.
High-Performance Protection for 110 V Installations
The IMO B6CR1N06-30-A-110 continuously monitors both load current and residual leakage current. In the event of an overload, short circuit or earth fault, the RCBO disconnects the supply rapidly, helping protect electrical wiring, connected equipment and personnel.
Its 110 V AC rating makes it particularly suitable for construction sites, temporary electrical installations, industrial maintenance systems and other reduced-voltage applications where enhanced electrical safety is required. The C Curve characteristic also accommodates the higher starting currents associated with transformers, motors and control equipment.
Typical Applications
- 110 V site power distribution.
- Construction and temporary electrical installations.
- Industrial control panels.
- Machine control circuits.
- Automation systems.
- Lighting circuits.
- OEM equipment.
- Maintenance power supplies.