£102.04Original price was: £102.04.£63.69Current price is: £63.69.
Why Choose the IMO B6CR1N20-30-A RCBO?
The IMO B6CR1N20-30-A is a high-performance Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to provide comprehensive protection against earth leakage, overload and short circuit faults in residential, commercial and industrial electrical installations. Manufactured to IEC 61009, it combines the functions of an MCB and RCD into a single compact device for simplified installation and enhanced circuit protection.
Part of the reliable IMO B6 RCBO range, this device features a Type A residual current protection, enabling it to detect both AC and pulsating DC residual currents commonly generated by modern electronic equipment. Its compact single-module design saves valuable DIN rail space while delivering dependable protection for individual circuits.
Rated at 20 A with a 30 mA residual operating current, a Type C tripping characteristic and a 6 kA short-circuit breaking capacity, the B6CR1N20-30-A is ideal for protecting circuits supplying lighting, socket outlets, commercial equipment and inductive loads where moderate inrush currents are expected.
Key Advantages
Combined RCBO protection against earth leakage, overload and short circuit.
20 A rated current suitable for a wide range of electrical circuits.
30 mA Type A residual current protection for enhanced user safety.
Type C tripping characteristic ideal for circuits with moderate inrush currents.
Compact single-module DIN rail design saves panel space.
High 6 kA breaking capacity for dependable fault protection.
Key Features
IMO B6 RCBO series.
20 A rated current.
30 mA residual operating current.
Type A residual current protection.
Type C tripping curve.
6 kA short-circuit breaking capacity.
1 Pole + Neutral (1P+N) configuration.
DIN rail mounting.
Finger-safe terminals.
Contact position indication window.
Compatible with IMO MCB accessories.
Technical Specifications
Manufacturer: IMO Precision Controls
Series: B6 RCBO
Model: B6CR1N20-30-A
Product type: Residual Current Circuit Breaker with Overcurrent Protection (RCBO)
Rated current: 20 A
Residual operating current: 30 mA
Residual current type: Type A
Tripping characteristic: Type C
Breaking capacity: 6 kA
Pole configuration: 1P+N
Rated voltage: 230 V AC
Frequency: 50 / 60 Hz
Standard: IEC 61009
Protection rating: IP20
Mounting type: 35 mm DIN rail
Module width: 18 mm
Reliable Electrical Circuit Protection
The IMO B6CR1N20-30-A continuously monitors electrical circuits for overloads, short circuits and earth leakage faults. If a fault is detected, the RCBO disconnects the supply rapidly, helping to protect personnel from electric shock whilst reducing the risk of equipment damage and electrical fires.
Its Type A residual current sensing makes it particularly suitable for installations containing modern electronic equipment, including appliances with switched-mode power supplies, LED lighting and variable speed devices that may generate pulsating DC leakage currents.
Typical Applications
Commercial electrical distribution boards.
Industrial control panels.
Residential consumer units.
Lighting circuits.
Socket outlet protection.
Small motors and inductive loads.
Building services installations.
General electrical installations.
Technical Specifications
Voltage
230 V
Phase
Single Phase
HS Code
8536201090
Country of Manufacture
China
Frequently Asked Questions
What is the IMO B6CR1N20-30-A used for?
It protects electrical circuits against earth leakage, overloads and short circuits by combining RCBO and MCB functionality in one device.
What does Type A residual current protection mean?
Type A RCBOs detect both alternating current (AC) and pulsating direct current (DC) earth leakage, making them suitable for modern electronic equipment.
What is the rated current of this RCBO?
The B6CR1N20-30-A has a rated current of 20 A.
What does the Type C tripping curve indicate?
Type C devices are intended for circuits with moderate inrush currents, such as motors, transformers and commercial electrical equipment.
How is the device installed?
The RCBO is designed for quick installation onto a standard 35 mm DIN rail inside electrical distribution boards and consumer units.
Trusted Protection for Modern Electrical Installations
IMO RCBOs are widely used by electrical contractors, panel builders and industrial engineers to deliver reliable protection against electrical faults while meeting modern installation standards.
{
"@context": "https://schema.org/",
"@type": "Product",
"name": "IMO B6CR1N20-30-A RCBO 20A 30mA Type A Type C 6kA",
"sku": "B6CR1N20-30-A",
"mpn": "B6CR1N20-30-A",
"brand": {
"@type": "Brand",
"name": "IMO Precision Controls"
},
"category": "Residual Current Circuit Breakers (RCBO)",
"description": "IMO B6CR1N20-30-A RCBO with 20 A rated current, 30 mA Type A residual current protection, Type C tripping characteristic and 6 kA breaking capacity for electrical circuit protection.",
"additionalProperty": [
{
"@type": "PropertyValue",
"name": "Rated current",
"value": "20 A"
},
{
"@type": "PropertyValue",
"name": "Residual current",
"value": "30 mA"
},
{
"@type": "PropertyValue",
"name": "Residual current type",
"value": "Type A"
},
{
"@type": "PropertyValue",
"name": "Tripping curve",
"value": "Type C"
},
{
"@type": "PropertyValue",
"name": "Breaking capacity",
"value": "6 kA"
}
]
}
{
"@context": "https://schema.org",
"@type": "FAQPage",
"inLanguage": "en-GB",
"mainEntity": [
{
"@type": "Question",
"name": "What is the IMO B6CR1N20-30-A used for?",
"acceptedAnswer": {
"@type": "Answer",
"text": "It protects electrical circuits against earth leakage, overloads and short circuits by combining RCBO and MCB functionality in one device."
}
},
{
"@type": "Question",
"name": "What does Type A residual current protection mean?",
"acceptedAnswer": {
"@type": "Answer",
"text": "Type A RCBOs detect both alternating current and pulsating direct current earth leakage, making them suitable for modern electronic equipment."
}
},
{
"@type": "Question",
"name": "What is the rated current of this RCBO?",
"acceptedAnswer": {
"@type": "Answer",
"text": "The device has a rated current of 20 A."
}
},
{
"@type": "Question",
"name": "What does the Type C tripping curve indicate?",
"acceptedAnswer": {
"@type": "Answer",
"text": "Type C devices are designed for circuits with moderate inrush currents such as motors, transformers and commercial equipment."
}
},
{
"@type": "Question",
"name": "How is the device installed?",
"acceptedAnswer": {
"@type": "Answer",
"text": "The RCBO is mounted onto a standard 35 mm DIN rail inside electrical distribution boards and consumer units."
}
}
]
}
Voltage
230 V
Phase
Single Phase
HS Code
8536201090
Country of Manufacture
China
No documents available for this product.
Delivery
We offer fast UK delivery on all stocked items. Orders placed before 3pm Monday to Friday are eligible for next-day delivery.
Standard delivery: 2–3 working days
Next-day delivery: available on in-stock items when ordered before 3pm
Express options available — contact us for details
Returns
If you need to return an item, please contact our sales team within 30 days of receipt. Items must be returned unused in their original packaging.
Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.
Priority sourcing and supply support
Flexible payment terms for qualifying organisations
Support for engineering, maintenance, and operations
500 +
Stock lines ready to ship
1,000 +
Same day dispatches
3500 +
Customers supported
28
Trusted Manfacturers
● frequently asked questions
Common questions about our products and support
At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.
What product ranges do you supply
We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products.
Can you help specify the correct part?
Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.
Do you have stock for urgent orders?
Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.
What are your delivery times and costs?
Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.
What about warranties, returns and faulty items?
Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.
LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.
2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...
2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...