The BS88 gM Type A4 fuse-link delivers reliable protection for motor and general applications, rated for 415VAC and 240VDC up to 160A with BTCP offset tag terminals for secure connections.
Price
List Priceex VAT
Your Price
On backorderPlease contact us for a delivery time before you order
Get the best trade pricesTrade exclusive
Create a trade account to unlock exclusive pricing, special offers and more.
Why Choose the Mersen BTCP42V100M160 British Standard Fuse-Link?
The Mersen BTCP42V100M160 is a robust British Standard gM fuse-link designed to provide dependable short-circuit protection for industrial motors and motor control circuits. Its motor-rated operating characteristic allows normal starting currents to pass while rapidly interrupting potentially damaging fault currents.
As part of the established Mersen BTCP offset tag fuse-link range, the BTCP42V100M160 is suitable for use in motor starters, switchgear, control panels and motor control centres. Its current-limiting performance helps reduce thermal and mechanical stress on cables, contactors and other downstream electrical equipment during a short circuit.
Featuring a 100M160 motor circuit rating and a nominal voltage rating of 415 V AC, this fuse-link is intended for demanding industrial installations. Its British Standard offset tag configuration enables secure installation in compatible fuse holders, fused switches and switch-disconnector assemblies.
Key Advantages
British Standard gM fuse-link designed for motor circuit protection.
100M160 motor circuit rating for demanding industrial applications.
415 V AC voltage rating suitable for common industrial power systems.
Accommodates normal motor starting currents without unnecessary operation.
Current-limiting performance helps minimise damage caused by short circuits.
Offset tag design provides secure installation in compatible fuse equipment.
Key Features
Mersen BTCP British Standard fuse-link series.
100M160 gM motor circuit rating.
415 V AC rated voltage.
gM utilisation category for motor circuit protection.
High fault-current interruption capability.
Effective current limitation during short-circuit conditions.
Robust industrial offset tag construction.
Compatible with suitable British Standard fuse holders and switchgear.
Technical Specifications
Manufacturer: Mersen
Series: BTCP Offset Tag Fuse-Links
Model: BTCP42V100M160
Product type: British Standard motor fuse-link
Fuse rating: 100M160
Rated AC voltage: 415 V AC
Utilisation category: gM
Fuse standard: BS88 / IEC 60269-2
Protection function: Motor circuit short-circuit protection
Mounting type: Offset tag
Operating principle: Current-limiting fuse-link
Application: Industrial motors and motor starter circuits
Installation: Compatible British Standard fuse holder or fused switchgear
Reliable Protection for Industrial Motor Circuits
Industrial motors can draw several times their normal operating current during start-up. The Mersen BTCP42V100M160 is engineered to withstand these temporary starting currents while providing fast and effective interruption when a serious short circuit occurs.
As a gM fuse-link, the BTCP42V100M160 is primarily intended to provide short-circuit protection. It should normally be coordinated with a suitable overload relay or motor protection device to provide comprehensive protection against both overload and fault-current conditions.
Typical Applications
Industrial motor starters.
Motor control centres.
Pumps, compressors and ventilation equipment.
Conveyors and material handling systems.
Manufacturing and processing machinery.
Industrial switchgear and control panels.
Technical Specifications
Item number
B226298
Catalogue No
BTCP42V100M160
Description
British Standard fuse-link IEC BS88 gM Type A4 415VAC 240VDC 100M160A BTCP Offset Tag
EAN/UPC Code
3605340519952
Rated voltage AC IEC
415 V
Rated voltage DC IEC
240 V
In M Ich
100M160 A
RoHS Compliant
Yes
AC or DC
AC/DC
Speed/Characteristic
gM
Fuse Size
A4
Mounting
Bolted
Clearing I2t At Rated Voltage
168000 A²s
Melting I2t
60000 A²s
AC Max I.R./Breaking Capacity
I1: 80 kA
Max. Rated Breaking Capacity DC
40 kA
Connection/Terminal Material
Tin-Plated Copper
Connection/Terminal Type
Offset Tag
Product Diameter
26.9 mm
Product Width
28.5 mm
Product Length
111 mm
Sell Pack Quantity
10 EA
Sell Pack Weight
1.1 kg
Sell Pack Width
120 mm
Sell Pack Length
230 mm
Sell Pack Height
40 mm
Product group
Low Voltage IEC Fuses
Body/Insulating Material
Ceramic
Product Weight
0.11 kg
Power Dissipation at Rated Current Value
8.8 W
HS Code
85361090
Country of Manufacture
India
Frequently Asked Questions
What is the Mersen BTCP42V100M160 used for?
It is a British Standard gM fuse-link designed to provide short-circuit protection for industrial motors, motor starters and associated electrical equipment.
What does the 100M160 rating mean?
The 100M160 designation identifies the fuse-link's motor circuit rating and its ability to accommodate the temporary high current produced when an industrial motor starts.
What voltage is the BTCP42V100M160 rated for?
The fuse-link has a nominal voltage rating of 415 V AC.
Does this fuse-link provide overload protection?
As a gM fuse-link, it is primarily intended for short-circuit protection and should normally be combined with a suitable overload relay or motor protection device.
Where is this fuse-link typically installed?
It is commonly installed in compatible British Standard fuse holders within motor starters, motor control centres, industrial switchgear and electrical control panels.
Trusted for Industrial Motor Protection
Mersen British Standard motor fuse-links are widely specified by electrical engineers, panel builders and industrial maintenance teams for reliable fault interruption, effective current limitation and dependable operation in demanding motor control systems.
Item number
B226298
Catalogue No
BTCP42V100M160
Description
British Standard fuse-link IEC BS88 gM Type A4 415VAC 240VDC 100M160A BTCP Offset Tag
EAN/UPC Code
3605340519952
Rated voltage AC IEC
415 V
Rated voltage DC IEC
240 V
In M Ich
100M160 A
RoHS Compliant
Yes
AC or DC
AC/DC
Speed/Characteristic
gM
Fuse Size
A4
Mounting
Bolted
Clearing I2t At Rated Voltage
168000 A²s
Melting I2t
60000 A²s
AC Max I.R./Breaking Capacity
I1: 80 kA
Max. Rated Breaking Capacity DC
40 kA
Connection/Terminal Material
Tin-Plated Copper
Connection/Terminal Type
Offset Tag
Product Diameter
26.9 mm
Product Width
28.5 mm
Product Length
111 mm
Sell Pack Quantity
10 EA
Sell Pack Weight
1.1 kg
Sell Pack Width
120 mm
Sell Pack Length
230 mm
Sell Pack Height
40 mm
Product group
Low Voltage IEC Fuses
Body/Insulating Material
Ceramic
Product Weight
0.11 kg
Power Dissipation at Rated Current Value
8.8 W
HS Code
85361090
Country of Manufacture
India
No documents available for this product.
Delivery
We offer fast UK delivery on all stocked items. Orders placed before 3pm Monday to Friday are eligible for next-day delivery.
Standard delivery: 2–3 working days
Next-day delivery: available on in-stock items when ordered before 3pm
Express options available — contact us for details
Returns
If you need to return an item, please contact our sales team within 30 days of receipt. Items must be returned unused in their original packaging.
Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.
Priority sourcing and supply support
Flexible payment terms for qualifying organisations
Support for engineering, maintenance, and operations
500 +
Stock lines ready to ship
1,000 +
Same day dispatches
3500 +
Customers supported
28
Trusted Manfacturers
● frequently asked questions
Common questions about our products and support
At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.
What product ranges do you supply
We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products.
Can you help specify the correct part?
Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.
Do you have stock for urgent orders?
Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.
What are your delivery times and costs?
Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.
What about warranties, returns and faulty items?
Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.
LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.
2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...
2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...