Why Choose the ABB S-ARC1 M B10 Arc Fault Detection Device?
The ABB S-ARC1 M B10 is a compact arc fault detection device (AFDD) with integrated miniature circuit breaker (MCB) designed to provide enhanced protection for single-phase final circuits. Part of the ABB S-ARC1 M series, it combines arc fault detection with thermal-magnetic overload and short-circuit protection within a single two-module DIN rail device.
The S-ARC1 M is designed to protect end-user single-phase circuits against earth, parallel and series arc faults as well as overloads and short-circuit currents. This allows the device to detect potentially hazardous electrical arcing that conventional MCB protection alone is not designed to identify, helping reduce the risk associated with electrically initiated fires.
With a rated current of 10 A, a B tripping characteristic and a rated operational voltage of 230–240 V AC, the S-ARC1 M B10 provides a 7.5 kA rated service short-circuit breaking capacity and a 10 kA rated ultimate short-circuit breaking capacity. Its 1P+N configuration and compact construction make it suitable for compatible residential and commercial final circuits requiring high short-circuit performance.
Key Advantages
- Combines arc fault detection and MCB protection in one compact device.
- 10 A rated current with B tripping characteristic.
- Protects against earth, parallel and series arc faults.
- Integrated thermal-magnetic protection against overloads and short circuits.
- 7.5 kA rated service short-circuit breaking capacity.
- 10 kA rated ultimate short-circuit breaking capacity.
- 1P+N configuration with one protected pole.
- Red ON / green OFF contact indication provides clear device status.
- Compact two-module design helps conserve distribution board space.
Key Features
- ABB S-ARC1 M arc fault detection device series.
- 10 A rated current.
- B tripping characteristic.
- 1P+N configuration with one protected pole.
- 230–240 V AC rated operational voltage.
- 50–60 Hz rated frequency.
- 7.5 kA rated service short-circuit breaking capacity.
- 10 kA rated ultimate short-circuit breaking capacity.
- 500 V rated insulation voltage.
- 4 kV rated impulse withstand voltage.
- Integrated thermal-magnetic MCB functionality.
- 2 W power loss.
- Red ON / green OFF contact position indication.
- IP20 terminal / IP40 housing protection.
- Operating temperature range from -25 to +55 °C.
- DIN rail mounting with screw terminals.
- Compact two-module construction.
Enhanced Arc Fault and High-Capacity Overcurrent Protection
Arc fault detection devices monitor electrical circuits for characteristics associated with potentially dangerous electrical arcing. The ABB S-ARC1 M is designed to protect end-user single-phase circuits against earth, parallel and series arc faults, while its integrated miniature circuit breaker provides thermal-magnetic protection against overloads and short-circuit currents.
The S-ARC1 M range provides enhanced short-circuit performance compared with the standard S-ARC1 range, with the S-ARC1 M B10 providing a 10 kA ultimate short-circuit breaking capacity. Combining AFDD and MCB functionality within a compact two-module device helps simplify distribution board design while providing protection against electrical faults that conventional MCBs alone are not designed to detect.
Typical Applications
- Residential electrical distribution boards.
- Commercial electrical distribution systems.
- Single-phase final circuits requiring enhanced arc fault protection.
- Circuits protected at 10 A requiring a B tripping characteristic.
- Lighting and compatible low-current final circuits.
- Applications requiring up to 10 kA ultimate short-circuit breaking capacity.
- Installations requiring combined arc fault, overload and short-circuit protection.