Why Choose the ABB S-ARC1 M B16 Arc Fault Detection Device?
The ABB S-ARC1 M B16 is a compact arc fault detection device (AFDD) with integrated miniature circuit breaker (MCB) designed to provide enhanced protection for single-phase final circuits. Part of the ABB S-ARC1 M series, it combines arc fault detection with thermal-magnetic overload and short-circuit protection within a single two-module DIN rail device.
The S-ARC1 M is designed to protect end-user single-phase circuits against earth, parallel and series arc faults as well as overloads and short-circuit currents. By detecting potentially hazardous electrical arcing that a conventional MCB alone is not designed to identify, it provides an additional level of protection against faults associated with damaged conductors, deteriorated insulation and poor electrical connections.
With a rated current of 16 A, a B tripping characteristic and a rated operational voltage of 230–240 V AC, the S-ARC1 M B16 provides a 7.5 kA rated service short-circuit breaking capacity and a 10 kA rated ultimate short-circuit breaking capacity. Its 1P+N configuration and compact construction make it suitable for compatible residential and commercial final circuits requiring enhanced short-circuit performance.
Key Advantages
- Combines arc fault detection and MCB protection in one compact device.
- 16 A rated current with B tripping characteristic.
- Protects against earth, parallel and series arc faults.
- Integrated thermal-magnetic protection against overloads and short circuits.
- 7.5 kA rated service short-circuit breaking capacity.
- 10 kA rated ultimate short-circuit breaking capacity.
- 1P+N configuration with one protected pole.
- Red ON / green OFF contact position indication provides clear device status.
- Compact two-module design helps conserve distribution board space.
Key Features
- ABB S-ARC1 M arc fault detection device series.
- 16 A rated current.
- B tripping characteristic.
- 1P+N configuration with one protected pole.
- 230–240 V AC rated operational voltage.
- 50–60 Hz rated frequency.
- 7.5 kA rated service short-circuit breaking capacity.
- 10 kA rated ultimate short-circuit breaking capacity.
- 500 V rated insulation voltage.
- 4 kV rated impulse withstand voltage.
- Integrated thermal-magnetic MCB functionality.
- 2.8 W power loss.
- Red ON / green OFF contact position indication.
- IP20 terminal / IP40 housing protection.
- Operating temperature range from -25 to +55 °C.
- DIN rail mounting with screw terminals.
- Compact two-module construction.
Enhanced Arc Fault and High-Capacity Overcurrent Protection
Arc fault detection devices monitor electrical circuits for characteristics associated with potentially dangerous electrical arcing. The ABB S-ARC1 M is designed to protect end-user single-phase circuits against earth, parallel and series arc faults, while its integrated miniature circuit breaker provides thermal-magnetic protection against overloads and short-circuit currents.
The S-ARC1 M range provides enhanced short-circuit performance, with the S-ARC1 M B16 offering a 7.5 kA service short-circuit breaking capacity and a 10 kA ultimate short-circuit breaking capacity. Combining AFDD and MCB functionality within a compact two-module device helps simplify distribution board design while providing protection against electrical faults that conventional MCBs alone are not designed to detect.
Typical Applications
- Residential electrical distribution boards.
- Commercial electrical distribution systems.
- Single-phase final circuits requiring enhanced arc fault protection.
- Circuits protected at 16 A requiring a B tripping characteristic.
- Compatible lighting and general-purpose final circuits.
- Applications requiring up to 10 kA ultimate short-circuit breaking capacity.
- Installations requiring combined arc fault, overload and short-circuit protection.