Why Choose the Mersen K095827 FR20GC155C0,63 High-Voltage Fuse?
The Mersen K095827, also identified as FR20GC155C0,63, is a specialist high-voltage cylindrical fuse-link designed to protect compatible electrical circuits and equipment against damaging overcurrents and short-circuit faults. With a rated current of 0.63 A and a voltage designation of 15.5 kV AC, it is suitable for low-current protection duties within professionally engineered high-voltage systems.
Manufactured as part of Mersen's established range of electrical protection products, the K095827 provides rapid fault interruption and current-limiting performance. This helps reduce the thermal and mechanical stress imposed on cables, control equipment and other components when excessive current occurs.
The fuse is identified by the manufacturer description 15500 CP GLC 20.254 0,63 and features a compact cylindrical format measuring approximately 20 × 254 mm. Its specialised electrical characteristics make correct coordination with the associated fuse holder, system voltage and protected equipment essential.
Key Advantages
- Reliable high-voltage overcurrent and short-circuit protection.
- 0.63 A rated current for sensitive low-current circuits.
- 15.5 kV AC voltage designation for compatible high-voltage systems.
- Current-limiting operation helps reduce damaging fault energy.
- Compact cylindrical format for compatible fuse holders and assemblies.
- Genuine Mersen component designed for dependable electrical protection.
Key Features
- Mersen K095827 high-voltage fuse-link.
- Alternative product reference: FR20GC155C0,63.
- Manufacturer description: 15500 CP GLC 20.254 0,63.
- 0.63 A nominal current rating.
- 15,500 V AC voltage designation.
- Cylindrical 20 × 254 mm fuse format.
- Fast fault interruption and current-limiting performance.
- Suitable for installation in compatible high-voltage fuse equipment.
Dependable Protection for High-Voltage Circuits
High-voltage fuse-links interrupt excessive current before serious thermal or mechanical damage can occur within the protected circuit. Their current-limiting action restricts the peak fault current and reduces the amount of energy allowed to pass through sensitive electrical equipment.
The Mersen K095827 should be selected according to the system voltage, normal operating current, prospective short-circuit level and characteristics of the protected equipment. Installation must be completed by suitably qualified personnel using a correctly rated and compatible fuse holder.
Typical Applications
- High-voltage control and protection circuits.
- Industrial electrical distribution equipment.
- Specialist lighting and infrastructure systems.
- Switchgear and fused protection assemblies.
- Protection of sensitive low-current electrical equipment.
- Replacement fuse-links for compatible Mersen installations.