Why Choose the Mersen FR14GG69V32 Cylindrical Fuse-Link?
The Mersen FR14GG69V32 is a high-performance gG cylindrical fuse-link designed to provide full-range protection against overloads and short circuits in industrial electrical distribution systems. Part of Mersen's established range of low-voltage IEC fuses, it combines dependable current-limiting performance with a robust 14 × 51 mm ceramic body.
Its gG operating characteristic enables the fuse-link to protect cables, conductors, motors, low-voltage networks and connected electrical equipment across the complete overcurrent range. During severe fault conditions, it rapidly limits and interrupts excessive current, helping reduce thermal and mechanical stress throughout the installation.
Rated at 32 A, 690 V AC and 250 V DC, the FR14GG69V32 offers a high 120 kA AC breaking capacity. Its compact cylindrical construction makes it suitable for compatible fuse holders installed within switchboards, machinery, automation panels and industrial distribution equipment.
Key Advantages
- Full-range gG protection against overloads and short circuits.
- 32 A rated current for industrial distribution applications.
- 690 V AC and 250 V DC ratings provide flexible system compatibility.
- 120 kA AC breaking capacity for dependable fault interruption.
- Current-limiting performance helps reduce damage to cables and equipment.
- Compact 14 × 51 mm format saves space within electrical panels.
Key Features
- Mersen FR14GG cylindrical fuse-link series.
- gG full-range fuse characteristic.
- 32 A rated current.
- 690 V AC IEC rated voltage.
- 250 V DC IEC rated voltage.
- 14 × 51 mm cylindrical fuse size.
- 120 kA AC breaking capacity.
- 100 kA DC breaking capacity at 250 V DC.
- Ceramic insulating body.
- Silver-plated copper ferrule terminals.
Reliable Full-Range Circuit Protection
The Mersen FR14GG69V32 protects electrical installations by limiting and disconnecting unacceptable overload and short-circuit currents. Its gG classification provides full-range protection, making it suitable for safeguarding conductors, motors and general low-voltage distribution equipment.
During a high-current fault, the fuse-link's current-limiting action reduces the energy passed to downstream equipment. This helps minimise thermal damage, mechanical stress and disruption within industrial control and power distribution systems.
Typical Applications
- Industrial electrical distribution systems.
- Cable and conductor protection.
- Low-voltage networks.
- Motor and machinery circuits.
- Automation and control panels.
- Switchboards and OEM electrical equipment.