MERSEN FUSE 90628-FUSE, TD CLASS CC ATQR2/10

MERSEN FUSE 90628-FUSE, TD CLASS CC ATQR2/10

Why Choose the MERSEN FUSE 90628-FUSE, TD CLASS CC ATQR2/10?

SKU: ATQR2/10Alt SKU: ATQR210MPN: ATQR2/10
Price
List Price £20.11 ex VAT
Your Price (ex VAT)
£20.11
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

SUBTOTAL (EX VAT) £20.11
Trade pricing is personalised to your account

Manufacturer Lead Time

Sold in packs of 10

£20.11

Why Choose the Mersen ATQR2/10 Class CC Fuse?

The Mersen ATQR2/10 is a compact, high-performance Class CC time-delay fuse engineered to provide dependable overcurrent protection for industrial control transformers, relays, solenoids and other inductive loads. As part of the renowned Mersen Amp-Trap® 2000 ATQR series, it combines advanced current-limiting protection with a time-delay characteristic that withstands normal equipment inrush currents while rapidly clearing fault conditions.

Designed specifically for branch circuit protection in industrial control systems, the ATQR2/10 helps minimise nuisance fuse operation during transformer energisation while protecting valuable electrical equipment against overloads and short circuits. Its rejection-style Class CC construction also helps prevent the installation of incompatible replacement fuses when used with the appropriate fuse holder.

With a rated current of 0.2 A, a maximum AC voltage rating of 600 V and a DC voltage rating of 300 V, the Mersen ATQR2/10 is ideally suited to sensitive industrial control circuits where reliable low-current protection is essential.

Key Advantages

  • Compact Class CC time-delay fuse for industrial control circuits.
  • 0.2 A current rating for sensitive control transformer protection.
  • 600 V AC and 300 V DC voltage ratings.
  • Time-delay characteristic withstands transformer and inductive-load inrush currents.
  • Current-limiting construction helps minimise fault energy.
  • Rejection-style design helps prevent incorrect fuse replacement.

Key Features

  • Mersen Amp-Trap® 2000 ATQR series.
  • 0.2 A rated current.
  • 600 V AC maximum voltage.
  • 300 V DC maximum voltage.
  • Class CC rejection-style ferrule fuse.
  • Time-delay operating characteristic.
  • High interrupting capacity for industrial fault protection.
  • Compact 10 × 38 mm cylindrical construction.

Reliable Protection for Industrial Control Systems

The Mersen ATQR2/10 is designed to protect low-current industrial control circuits where reliability is essential. Its time-delay performance allows normal transformer magnetising current and equipment start-up surges to pass without nuisance operation while still providing rapid interruption of sustained overloads and short circuits.

Its current-limiting design reduces thermal and mechanical stress during fault conditions, helping protect sensitive control equipment, reduce downtime and improve the long-term reliability of industrial electrical systems.

Typical Applications

  • Industrial control transformers.
  • Control panels and switchboards.
  • Relays, solenoids and contactors.
  • PLC and automation control circuits.
  • OEM machinery.
  • Industrial automation equipment.

Technical Specifications

Manufacturer Mersen
Series Amp-Trap® 2000 ATQR
Model ATQR2/10
Product type Class CC time-delay fuse
Fuse class Class CC
Rated current 0.2 A
Rated AC voltage 600 V AC
Rated DC voltage 300 V DC
Frequency 50 / 60 Hz
Interrupting rating 200 kA AC, 100 kA DC
Operating characteristic Time delay
Fuse body Ferrule
Mounting type Compatible Class CC fuse holder
Dimensions 10 × 38 mm
HS Code 85361010
Country of Manufacture Mexico
Device Type Fuse link
Fuse Type UL class
Fuse Class Time delay
Current 0.2 A

Frequently Asked Questions

What is the Mersen ATQR2/10 used for?

The ATQR2/10 is designed to protect industrial control transformers, relays, solenoids and other low-current inductive control circuits.

What is the current rating of the ATQR2/10?

The fuse has a rated current of 0.2 A.

What voltage is the ATQR2/10 rated for?

The fuse is rated for applications up to 600 V AC and 300 V DC.

Why is a time-delay fuse used for control transformers?

A time-delay fuse tolerates temporary transformer inrush currents while continuing to provide dependable protection against overloads and short circuits.

What fuse holder should be used?

The Mersen ATQR2/10 should be installed in a compatible Class CC rejection-style fuse holder.

Trusted Protection for Industrial Electrical Systems

Mersen Amp-Trap® 2000 ATQR Class CC fuses are trusted by panel builders, OEMs and maintenance engineers for dependable branch circuit protection in industrial control applications.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Priority sourcing and supply support

 Flexible payment terms for qualifying organisations

 Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...