Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
The NH fuse-switch disconnector MULTIVERT® Size 1 250A provides reliable protection and isolation in demanding industrial environments, integrating seamlessly into 185mm bus bar systems with a robust 1×3-pole switching configuration.
£541.46
The Mersen S1023194 is a high-performance MULTIVERT® NH Size 1 vertical fuse switch disconnector designed for switching, isolation and circuit protection in industrial low-voltage power distribution systems. Engineered for direct installation onto 185 mm busbar systems, it combines dependable switching performance with integrated current measurement in a compact modular assembly.
Rated at 250 A and 690 V AC, the S1023194 is designed for use with NH Size 1 fuse-links in accordance with IEC/EN 60269-2. This model incorporates an integrated 100/5 A, 2 VA Class 1 current transformer for triple-pole measurement, eliminating the need for separate current transformer installation while maintaining the standard installation depth.
Featuring 1 × 3-pole simultaneous switching, M10 bolted cable terminals and a modular MULTIVERT® design, the S1023194 offers safe on-load switching, reliable electrical isolation and accurate current monitoring for industrial switchboards, transformer substations and distribution panels.
The Mersen S1023194 combines load switching, circuit isolation, fuse protection and current monitoring within a single compact device. Its integrated 100/5 A Class 1 current transformer provides accurate three-phase current measurement for energy monitoring, metering and protection systems without increasing installation depth.
Designed for direct mounting onto 185 mm busbars, the MULTIVERT® system reduces installation time while maintaining a neat switchboard layout. Its modular construction also allows straightforward servicing and compatibility with a wide range of genuine Mersen accessories.
Tick the specs you need, then view products that match.
| Mounting Type | Busbar system 185 mm | |
|---|---|---|
| Current | 250 A | |
| Phase | Three Phase | |
| Poles | 3-pole | |
| Device Type | Fuse switch disconnector | |
| Voltage | 690 V | |
| Item number | S1023194 | |
| Catalogue No | 1.150.091 | |
| Description | NH fuse-switch disconnector MULTIVERT® Size 1 250A 1x3-Pole switching Bus bar system 185mm Screw M10 ct100A | |
| EAN/UPC Code | 9008567001295 | |
| Frequency (Hz) | 50 ... 60 Hz | |
| Rated voltage AC IEC | 690 V | |
| Ampere Rating | 250 A | |
| Utilization Category | AC 23 B @ Ue = AC 400 V; Ie = 250 A AC 23 B @ Ue = AC 500 V; Ie = 250 A AC 22 B @ Ue = AC 690 V; Ie = 250 A | |
| Switchability | 1x3-pole switching | |
| RoHS Compliant | Yes | |
| AC or DC | AC | |
| Short Circuit Current Rating (SCCR) | 120kA@Ue = AC 400 V; Ie = 250 A / 120kA@Ue = AC 500 V; Ie = 250 A / 120kA@Ue = AC 690 V; Ie = 250 A | |
| Fuse Size | 1 | |
| Design Details | MULTIVERT® 1.150.000 with integrated C.T. 100/5A, 2,00 VA, class 1 for triple pole measurement | |
| Number of Poles | 3-Pole | |
| Degree of Pollution | 3 | |
| Rated Impulse Withstand Voltage | 12 kV | |
| Rated Insulation Voltage | 1000 V | |
| Rated SC Withstand | 8 kA / 1 s | |
| Max Power dissipation of Fuse Links Pn | 23 W | |
| Max Power dissipation of Solid Links Pn | 2.6 W | |
| Power Dissipation by Ith without Fuse-Links | 35 W | |
| Power Dissipation by Ith without Solid Links | 90 W | |
| Rated short circuit making capacity with solid links Icm | 16 kA | |
| Installation Mounting | Bus bar system 185 mm | |
| Product Width | 98 mm | |
| Product Length | 190 mm | |
| Product Height | 685 mm | |
| Sell Pack Quantity | 1 EA | |
| Sell Pack Weight | 5.4 kg | |
| Sell Pack Width | 100 mm | |
| Sell Pack Length | 688 mm | |
| Sell Pack Height | 195 mm | |
| Product group | IEC Fuse Switch Disconnectors | |
| Conventional Free Air thermal Current With Fuse-Links Ith | 250 A | |
| Product Weight | 5.4 kg | |
| Conventional Free Air thermal Current - Solid Links | 400 A |
It is an NH Size 1 fuse switch disconnector used for switching, isolation, circuit protection and integrated three-phase current measurement in industrial power distribution systems.
The Mersen S1023194 has a rated operating current of 250 A.
Yes. It incorporates an integrated 100/5 A, 2 VA, Class 1 current transformer for triple-pole current measurement.
The switch disconnector is designed for direct installation onto a 185 mm busbar system.
The S1023194 is designed for NH Size 1 fuse-links manufactured in accordance with IEC/EN 60269-2 and VDE 0636-2.
Mersen MULTIVERT® fuse switch disconnectors are trusted by panel builders, OEM manufacturers and industrial electrical engineers for dependable switching, integrated current measurement and reliable circuit protection within modern low-voltage distribution systems.