MERSEN FUSE MV3 630A/185mm 3P3 1.350.000 1.350.000

MERSEN FUSE MV3 630A/185mm 3P3 1.350.000 1.350.000

Robust and reliable three-phase NH fuse-switch disconnector for industrial bus bar systems, rated 630 A and 690 V AC, with screw M12 bolt connections and 1×3-pole switching.

SKU: N1002191Alt SKU: 1.350.000MPN: N1002191
Price
List Price £432.47 ex VAT
Your Price (ex VAT) Save 40%
£259.48 40% OFF
You save £172.99 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £259.48
Trade pricing is personalised to your account

Manufacturer Lead Time

£259.48

Why Choose the Mersen N1002191 MULTIVERT® NH Fuse-Switch Disconnector?

The Mersen N1002191 is a heavy-duty MULTIVERT® NH vertical fuse-switch disconnector designed for high-current industrial power distribution systems. Also identified by catalogue number 1.350.000, this robust three-pole unit is rated at 630 A and accommodates standard NH size 3 fuse-links in accordance with IEC/EN 60269-2.

Designed for direct installation onto standard 185 mm busbar systems, the N1002191 provides a compact, modular solution for low-voltage switchboards, motor control centres and industrial distribution panels. The standard design offers a shallow installation depth of approximately 123 mm, helping maximise available cabinet space while simplifying installation and maintenance.

This version features three M12 bolt cable terminations and a single three-pole switching mechanism, delivering dependable isolation and protection for demanding industrial applications operating at up to 690 V AC.

Key Advantages

  • 630 A rated current for high-power distribution systems.
  • Designed for NH size 3 fuse-links.
  • Direct mounting onto standard 185 mm busbar systems.
  • Three-pole switching for three-phase installations.
  • M12 bolt cable connections provide secure conductor termination.
  • Compact installation depth of approximately 123 mm.
  • Modular MULTIVERT® design simplifies installation and servicing.
  • Suitable for demanding industrial and commercial power distribution.

Key Features

  • Mersen MULTIVERT® Size 3 fuse-switch disconnector.
  • 630 A rated operational current.
  • 690 V AC rated voltage.
  • NH size 3 fuse-link compatibility.
  • 185 mm busbar system.
  • Three-pole switching arrangement.
  • 3 × M12 bolt cable terminations.
  • Designed for 50/60 Hz electrical systems.
  • Short-circuit rating up to 80 kA (application dependent).
  • Suitable for industrial low-voltage switchboards and feeder circuits.

Designed for High-Current Industrial Distribution

The Mersen N1002191 combines safe isolation, overload protection and reliable switching into a compact vertical assembly that mounts directly onto standard 185 mm busbars. Its modular MULTIVERT® construction enables rapid installation while helping reduce the space required within modern power distribution cabinets.

Designed for use with NH size 3 fuse-links, the unit provides dependable protection for high-current feeder circuits, industrial machinery and distribution systems. Genuine MULTIVERT® components help maintain compatibility, operational safety and long-term reliability.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main distribution panels.
  • Motor control centres.
  • Power distribution cabinets.
  • Industrial machinery protection.
  • OEM switchboard manufacturing.
  • Infrastructure electrical systems.
  • Commercial high-current installations.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Busbar system 185 mm
Current 630 A
Phase Three Phase
Poles 3-pole
Device Type Fuse switch disconnector
Voltage 690 V
Item number N1002191
Catalogue No 1.350.000
Description NH fuse-switch disconnector MULTIVERT® Size 3 630A 1x3-Pole switching Bus bar system 185mm Screw M12 bolt
EAN/UPC Code 9008567000304
Frequency (Hz) 50 ... 60 Hz
Rated voltage AC IEC 690 V
Ampere Rating 630 A
Utilization Category AC 23 B @ Ue = AC 400 V; Ie = 630 A AC 22 B @ Ue = AC 500 V; Ie = 630 A AC 21 B @ Ue = AC 690 V; Ie = 630 A
Switchability 1x3-pole switching
RoHS Compliant Yes
AC or DC AC
Short Circuit Current Rating (SCCR) 80kA@Ue = AC 400 V; Ie = 630 A / 80kA@Ue = AC 500 V; Ie = 630 A / 80kA@Ue = AC 690 V; Ie = 500 A
Fuse Size 3
Number of Poles 3-Pole
Degree of Pollution 3
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 V
Rated SC Withstand 12.6 kA / 1 s
Max Power dissipation of Fuse Links Pn 48 W
Max Power dissipation of Solid Links Pn 17.5 W
Power Dissipation by Ith without Fuse-Links 95 W
Rated short circuit making capacity with solid links Icm 16 kA
Installation Mounting Bus bar system 185 mm
Product Width 98 mm
Product Length 190 mm
Product Height 685 mm
Sell Pack Quantity 1 EA
Sell Pack Weight 5.59 kg
Sell Pack Width 200 mm
Sell Pack Length 705 mm
Sell Pack Height 105 mm
Product group IEC Fuse Switch Disconnectors
Conventional Free Air thermal Current With Fuse-Links Ith 630 A
Product Weight 5.59 kg
Conventional Free Air thermal Current - Solid Links 800 A
HS Code 85365080
Country of Manufacture Hungary

Frequently Asked Questions

What is the Mersen N1002191 used for?

The N1002191 is an NH size 3 vertical fuse-switch disconnector used to provide switching, isolation and fuse protection for high-current three-phase distribution systems.

What is the rated current?

The unit has a rated operational current of 630 A.

Which fuse-links are compatible?

The N1002191 is designed for standard NH size 3 fuse-links manufactured to IEC/EN 60269-2.

Which busbar system does it fit?

The disconnector is designed for direct installation onto a standard 185 mm busbar system.

What cable connection does the N1002191 use?

This version is supplied with three M12 bolt cable terminations for secure conductor connections.

Trusted High-Current Power Distribution

Mersen MULTIVERT® fuse-switch disconnectors are trusted worldwide by panel builders, industrial engineers and electrical contractors for delivering safe isolation, reliable circuit protection and efficient installation in demanding low-voltage distribution systems.