Why Choose the Mersen NH000GG69V10-1 NH Fuse Link?
The Mersen NH000GG69V10-1 is a compact and dependable NH000 gG fuse link designed to provide full-range protection for cables, conductors and industrial electrical equipment. Manufactured as part of Mersen’s low-voltage IEC fuse range, this DIN-standard fuse link protects appropriately rated circuits against both sustained overloads and high short-circuit currents.
Featuring a gG operating characteristic, the NH000GG69V10-1 can interrupt fault currents ranging from the lowest operating current through to its maximum breaking capacity. Its current-limiting performance helps reduce the thermal and electrodynamic stress placed on cables, switchgear and connected equipment during electrical faults.
With a rated current of 10 A, an AC voltage rating of 690 V and a DC voltage rating of 250 V, this NH size 000 fuse link is suitable for industrial distribution boards, control panels and machinery circuits. Its double indicator enables rapid identification of fuse operation, while the isolated gripping lugs support safer handling by qualified electrical personnel.
Key Advantages
- Full-range gG protection against overloads and short circuits.
- 10 A rated current for lower-current industrial circuits.
- Suitable for electrical systems rated up to 690 V AC and 250 V DC.
- High 80 kA AC breaking capacity for dependable fault interruption.
- Double indication system enables quick identification of an operated fuse.
- Isolated gripping lugs improve handling safety during professional replacement.
Key Features
- Mersen NH gG 690 V AC fuse-link series.
- 10 A ampere rating.
- 690 V AC rated voltage.
- 250 V DC rated voltage.
- NH000 DIN fuse size.
- gG full-range operating characteristic.
- Integrated double fuse-operation indicator.
- Isolated metal gripping lugs.
- Silver-plated copper plain-blade terminals.
- Durable ceramic insulating body.
Reliable Protection for Industrial Electrical Circuits
The Mersen NH000GG69V10-1 disconnects an electrical circuit when excessive current exceeds the fuse’s operating threshold. Its current-limiting action reduces the amount of damaging energy passed to cables, switchgear and connected electrical equipment during short-circuit conditions.
As a gG full-range fuse link, this model protects against both overload currents and high short-circuit currents. It can therefore be used as the primary protective fuse in appropriately designed circuits. Installation and replacement should only be completed by qualified electrical personnel using a compatible NH fuse base and approved fuse-handling equipment.
Typical Applications
- Industrial power distribution boards.
- Electrical control panels and cabinets.
- Cable and conductor protection.
- Auxiliary and control power circuits.
- Industrial machinery supply circuits.