Why Choose the Mersen NH1GG40V50 NH Fuse-Link?
The Mersen NH1GG40V50 is a reliable DIN NH gG fuse-link designed to provide full-range protection against overloads and short-circuit currents in low-voltage electrical distribution systems. Its industrial construction and dependable current-limiting performance make it suitable for protecting cables, conductors, switchgear and connected electrical equipment.
As part of Mersen's NH gG 400 V AC fuse-link range, the NH1GG40V50 offers a high breaking capacity and an integrated double indication system. During a fault, the fuse-link helps limit the electrical energy passed downstream, reducing thermal and mechanical stress on cables, busbars and switchgear while enabling maintenance personnel to identify an operated fuse quickly.
Rated at 50 A and 400 V AC, this NH1 fuse-link features live gripping lugs, plain blade terminals and a durable ceramic insulating body. It is designed for installation in compatible NH1 fuse bases and fuse-switch disconnectors within industrial, commercial and infrastructure power distribution systems.
Key Advantages
- Full-range gG protection against overloads and short circuits.
- 50 A rated current for low-voltage distribution circuits.
- 400 V AC rated operating voltage.
- High 100 kA AC breaking capacity for dependable fault interruption.
- Double indicator enables rapid identification of an operated fuse-link.
- Current-limiting performance helps protect cables and electrical equipment.
Key Features
- Mersen NH gG 400 V AC fuse-link series.
- DIN NH1 fuse size.
- 50 A rated current.
- 400 V AC rated voltage.
- gG full-range operating characteristic.
- 100 kA AC breaking capacity.
- Double fuse operation indicator.
- Live gripping lugs.
- Silver-plated copper blade terminals.
- Durable ceramic insulating body.
- 30 mm body width.
Reliable Protection for Low-Voltage Distribution Systems
gG fuse-links provide full-range protection for cables, conductors and general-purpose electrical equipment. They are capable of interrupting currents from sustained overload conditions through to severe short-circuit faults, allowing the fuse-link to function as the primary protective device for suitable circuits.
The Mersen NH1GG40V50 limits the peak current and energy transmitted during a fault, helping protect downstream equipment from damaging electrodynamic and thermal effects. Installation, replacement and maintenance should be completed by qualified electrical professionals using suitable NH fuse-handling equipment.
Typical Applications
- Industrial low-voltage distribution systems.
- Electrical switchboards and control panels.
- Cable and conductor protection.
- Industrial machinery power circuits.
- Commercial building electrical installations.
- NH1 fuse bases and fuse-switch disconnectors.