Why Choose the Mersen NH22GTR250KVA Transformer Fuse-Link?
The Mersen NH22GTR250KVA is a high-performance DIN NH gTr transformer protection fuse-link developed to provide dependable overload and short-circuit protection for low voltage distribution transformers. Manufactured by Mersen, this NH2 fuse-link is specifically engineered with characteristics matched to transformer applications, allowing it to withstand normal transformer energisation currents whilst providing rapid protection against fault conditions.
Part of the proven Mersen NH gTr 400 V AC fuse-link series, the NH22GTR250KVA is designed for transformers with a nominal capacity of 250 kVA. It features a 361 A rated current, 400 V AC operating voltage, a centre indicator and live gripping lugs, making it ideal for industrial power distribution systems and transformer installations.
Its NH2 construction offers high breaking capacity together with reliable long-term performance, making it suitable for transformer switchboards, substations, commercial buildings and industrial electrical distribution systems where dedicated transformer protection is essential.
Key Advantages
- Purpose-designed gTr fuse-link for transformer protection.
- Suitable for 250 kVA low voltage transformers.
- 361 A rated current for transformer applications.
- 400 V AC operating voltage.
- Centre indicator enables rapid identification of an operated fuse.
- Live gripping lugs support safe replacement using an approved NH fuse puller.
- High 100 kA breaking capacity for demanding fault conditions.
- Manufactured in accordance with IEC NH standards.
Key Features
- Mersen NH gTr transformer protection fuse-link series.
- Catalogue number: NH22GTR250KVA.
- Mersen item number: H1030499.
- Fuse size: NH2.
- Transformer capacity: 250 kVA.
- Rated current: 361 A.
- Rated voltage: 400 V AC.
- Utilisation category: gTr.
- Centre operated-fuse indicator.
- Live gripping lugs.
- Blade contact construction.
- Body width: 50 mm.
Reliable Protection for Distribution Transformers
The Mersen NH22GTR250KVA is specifically designed for transformer protection. Its gTr operating characteristic accommodates transformer magnetising inrush currents whilst providing dependable protection against overloads and high prospective short-circuit currents, helping maximise transformer reliability and service life.
The fuse-link should be installed in a compatible NH2 fuse base and handled only by qualified electrical personnel using an approved NH fuse replacement device and appropriate personal protective equipment.
Typical Applications
- 250 kVA low voltage distribution transformers.
- Industrial transformer switchboards.
- Commercial power distribution systems.
- Electrical substations.
- Industrial switchboards.
- Manufacturing and process facilities.