Why Choose the Mersen NH3GTR100KVA-1 NH Fuse Link?
The Mersen NH3GTR100KVA-1 is a high-quality DIN NH gTr fuse link designed specifically for the protection of low voltage distribution transformers. Manufactured by Mersen, this NH3 fuse link features a transformer-specific operating characteristic that accommodates transformer energisation currents while delivering reliable overload and short circuit protection.
As part of the trusted Mersen NH gTr fuse series, the NH3GTR100KVA-1 incorporates isolated gripping lugs and a centre operating indicator, allowing safer handling and rapid identification of an operated fuse. Its robust ceramic construction and high breaking capacity make it ideal for industrial, commercial and utility power distribution systems.
With a rated current of 144 A, a 400 V AC voltage rating and suitability for 100 kVA transformers, the NH3GTR100KVA-1 delivers dependable transformer protection while helping minimise equipment damage and system downtime.
Key Advantages
- Designed specifically for distribution transformer protection.
- 144 A rated current for 100 kVA transformer applications.
- 400 V AC rated voltage for industrial power systems.
- Transformer-specific gTr operating characteristic.
- High current-limiting performance for improved equipment protection.
- 100 kA breaking capacity for dependable fault interruption.
- Integrated centre operating indicator.
- Isolated gripping lugs for safer fuse replacement.
Key Features
- Mersen NH gTr transformer protection fuse.
- NH3 fuse size.
- 144 A rated current.
- 400 V AC rated voltage.
- Designed for 100 kVA transformers.
- Centre operating indicator.
- Isolated gripping lugs.
- Ceramic fuse body.
- High breaking capacity.
- RoHS compliant.
The Mersen NH3GTR100KVA-1 is engineered using a gTr time-current characteristic specifically developed for transformer protection. It tolerates normal transformer magnetising inrush currents while rapidly disconnecting overload and short circuit faults, helping extend transformer life and improve electrical system reliability.
Its current-limiting design reduces thermal and mechanical stress during fault conditions, protecting transformers, switchgear and associated distribution equipment. Installation and replacement should always be carried out by qualified personnel using suitable NH fuse handling tools.
Typical Applications
- 100 kVA distribution transformer protection.
- Industrial switchboards.
- Commercial electrical installations.
- Utility distribution systems.
- OEM electrical control panels.
- Power distribution equipment.