SKU: PMA50A415MPN: PMA50A415
PMA50A415 - PUMP PROTECTION RELAY 380-415VAC

PMA50A415 – PUMP PROTECTION RELAY 380-415VAC

Lovato PMA50A415 pump protection relay for single-phase and three-phase systems, providing maximum AC current, minimum power factor, phase loss and incorrect phase sequence monitoring with a 380–415 V AC supply.

Price
List Price ex VAT
Your Price
On backorder Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

Trade pricing is personalised to your account

Available on backorder

£297.57

Why Choose the Lovato PMA50A415 Pump Protection Relay?

The Lovato PMA50A415 is a multifunction pump protection relay designed to monitor and protect single-phase and three-phase pump motors against abnormal operating conditions. As part of the dependable Lovato Electric PMA50 monitoring relay series, it combines maximum AC current monitoring with minimum power factor supervision to identify overloads, underload conditions and dry-running pumps.

Designed for systems operating from a 380–415 V AC auxiliary supply, the PMA50A415 provides selectable 5 A or 16 A current measurement ranges. Higher motor currents can be monitored through a suitable current transformer, allowing the relay to protect a wide range of pump sizes and industrial pumping installations.

The PMA50A415 also monitors phase loss and incorrect phase sequence in three-phase systems. Adjustable current, power factor and timing controls allow the relay to be configured around the operating characteristics of the connected pump, providing effective motor protection and helping prevent costly equipment damage when dependable operation is worth its salt.

Key Advantages

  • Dedicated pump protection relay for single-phase and three-phase systems.
  • Detects maximum AC current to protect against sustained overload conditions.
  • Monitors minimum power factor to detect dry running and underload.
  • Provides phase loss and incorrect phase sequence protection.
  • Selectable 5 A or 16 A current ranges.
  • Suitable for direct current measurement or connection through a current transformer.
  • Adjustable thresholds and timing functions for application-specific protection.
  • Compact DIN rail format for pump control panels.

Key Features

  • Lovato Electric PMA50 series.
  • Maximum AC current monitoring.
  • Minimum cosφ monitoring for dry-running protection.
  • Phase loss detection.
  • Incorrect phase sequence detection.
  • 5 A or 16 A selectable current measurement range.
  • 380–415 V AC auxiliary supply.
  • Adjustable maximum current threshold.
  • Adjustable minimum power factor threshold.
  • Adjustable start-up inhibition and trip delay.
  • Manual or automatic reset operation.
  • 1 changeover relay output.
  • LED indication for supply, inhibition and trip conditions.
  • Screw terminal connections.
  • DIN rail mounting.

Comprehensive Protection for Pump Motors

A pump motor can continue drawing electrical current even when the pump is running without sufficient fluid. The Lovato PMA50A415 monitors both motor current and power factor, allowing it to identify dry running, loss of prime, blocked pumps and sustained overload conditions that may not be detected by conventional overcurrent protection alone.

When an abnormal condition remains present beyond the selected delay, the relay changes the state of its output contact. This can stop the pump, activate an alarm or send a fault signal to a PLC or control system, helping prevent overheating, seal damage and premature motor or pump failure.

Typical Applications

  • Borehole and submersible pumps.
  • Water supply and booster pump systems.
  • Irrigation and agricultural pumping equipment.
  • Wastewater and drainage pumps.
  • Industrial process pumps.
  • Cooling water and circulation systems.
  • Three-phase pump control panels.
  • Motor underload and overload protection systems.

Technical Specifications

Voltage 415 V
Phase Single Phase
Manufacturer Lovato Electric
Series PMA50
Model PMA50A415
Product type Pump protection relay
System type Single-phase and three-phase
Measured current type AC
Monitoring functions Maximum current, minimum cosφ, phase loss and incorrect phase sequence
Auxiliary supply voltage 380–415 V AC
Operating voltage range 0.85–1.1 × Us
Rated frequency 50 / 60 Hz ±5%
Maximum power consumption 4.5 VA
Selectable current ranges 5 A or 16 A
Maximum current threshold adjustment 5–100% of selected range
Minimum power factor adjustment 0.10–0.99 cosφ
Measurement connection Direct or via current transformer
Reset mode Manual or automatic
Relay outputs 1 changeover contact
Contact configuration SPDT
Conventional thermal current 8 A
Output operating mode Normally energised, de-energises on trip
Status indication Green supply/inhibition LED and red trip LEDs
Terminal type Screw terminals
Mounting type DIN rail
Modular width 3 modules
Front protection rating IP40
Terminal protection rating IP20
Operating temperature -20°C to +60°C
Dimensions (W × H × D) Approx. 53.5 × 104.7 × 64.9 mm
Compliance IEC/EN 60255-5, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL 508 and CSA C22.2 No. 14
HS Code 85364900

Frequently Asked Questions

What is the Lovato PMA50A415 used for?

The PMA50A415 protects single-phase and three-phase pump motors against overcurrent, dry running, phase loss and incorrect phase sequence.

How does the PMA50A415 detect dry running?

It monitors the motor power factor and trips when the measured cosφ falls below the selected minimum threshold, indicating that the pump may be operating without sufficient fluid or mechanical load.

What current ranges can the PMA50A415 monitor?

The relay provides selectable 5 A and 16 A ranges. Higher motor currents can be monitored using a suitable current transformer.

What supply voltage does the PMA50A415 require?

The relay operates from a 380–415 V AC auxiliary supply at 50 or 60 Hz.

Does the relay protect against phase faults?

Yes. In three-phase applications, the PMA50A415 detects phase loss and incorrect phase sequence, helping prevent motor damage and incorrect pump rotation.

Can the PMA50A415 be manually reset?

Yes. The relay supports manual or automatic reset operation, allowing the required restart sequence to be selected for the application.

Trusted Pump Protection for Industrial Systems

Lovato Electric monitoring relays are used by panel builders, pump installers and automation engineers to protect motors, detect abnormal operating conditions and improve the reliability of industrial pumping systems.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Tick  Priority sourcing and supply support

 Tick  Flexible payment terms for qualifying organisations

 Tick  Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...