Lovato PMVF70 interface protection system compliant with ENA G59 and G99 for single-phase and three-phase 230 V and 400 V AC generation installations, featuring voltage, frequency, ROCOF and vector shift protection.
Price
List Priceex VAT
Your Price
On backorderPlease contact us for a delivery time before you order
Get the best trade pricesTrade exclusive
Create a trade account to unlock exclusive pricing, special offers and more.
Why Choose the Lovato PMVF70 Interface Protection System?
The Lovato PMVF70 is a dedicated interface protection system unit designed for electricity generation installations operating in parallel with public distribution networks. Developed for UK applications, it complies with the Energy Networks Association G59 and G99 engineering recommendations and continuously monitors the grid connection for abnormal voltage, frequency and loss-of-mains conditions.
Suitable for single-phase and three-phase systems, the PMVF70 can be used on low-voltage networks or on high-voltage installations through suitable external measurement transformers. It provides dual-threshold minimum and maximum voltage protection, dual-threshold minimum and maximum frequency protection, rate of change of frequency monitoring and vector shift detection.
The PMVF70 supports 230 V and 400 V AC networks, external current transformers with 1 A or 5 A secondary outputs and two changeover relay outputs. Its modular DIN rail design and optional communication expansion modules make it suitable for photovoltaic systems, wind generation, cogeneration plants and industrial generation projects. Lovato Electric currently lists this model as out of catalogue, so customers should contact LED Controls to confirm availability or discuss a suitable replacement.
Key Advantages
Dedicated interface protection for UK grid-connected generation systems.
Compliant with ENA G59 and G99 engineering recommendations.
Suitable for single-phase and three-phase systems.
Supports systems with or without a neutral conductor.
Dual-threshold minimum and maximum voltage protection.
Dual-threshold minimum and maximum frequency monitoring.
Integrated ROCOF and vector shift loss-of-mains protection.
Optional communication modules support remote monitoring and system integration.
Key Features
Lovato PMVF series interface protection system.
Designed for low and high-voltage generation installations.
230 V and 400 V AC network monitoring.
Single-phase and three-phase system compatibility.
Dual minimum-voltage thresholds.
Dual maximum-voltage thresholds.
Dual minimum-frequency thresholds.
Dual maximum-frequency thresholds.
Rate of change of frequency monitoring.
Vector shift protection for loss-of-mains detection.
External 1 A or 5 A current transformer inputs.
Two SPDT changeover relay outputs.
Four isolated 12 V DC digital inputs.
True RMS current measurement.
Removable screw terminals for straightforward panel wiring.
Reliable UK Grid Interface Protection
Electricity generation equipment connected in parallel with a public distribution network must disconnect automatically when grid voltage, frequency or stability moves outside authorised limits. The Lovato PMVF70 continuously supervises these parameters and controls the external interface device when a configured protection threshold is exceeded.
ROCOF and vector shift monitoring provide additional loss-of-mains detection alongside conventional voltage and frequency protection. This helps prevent unintended island operation and supports safe disconnection of photovoltaic, wind, cogeneration and other distributed generation systems from the public network.
Typical Applications
Grid-connected photovoltaic installations.
Wind turbine generation systems.
Cogeneration and combined heat and power plants.
Commercial and industrial generation systems.
Low-voltage distributed generation projects.
High-voltage generation installations using external transformers.
Parallel generator connections.
UK grid interface protection panels.
Technical Specifications
Manufacturer
Lovato Electric
Series
PMVF
Model
PMVF70
Product type
Interface protection system unit
System type
Single-phase and three-phase
Neutral configuration
With or without neutral
Network voltage
230 / 400 V AC
Applicable recommendations
ENA G59 / G99
Operating supply range
85–264 V AC / 93.5–300 V DC
Rated auxiliary supply
100–240 V AC / 110–250 V DC
Rated frequency
45–55 Hz
Maximum operational voltage
400 V AC line-to-line / 230 V AC line-to-neutral
Voltage measurement range
20–480 V AC line-to-line / 10–276 V AC line-to-neutral
Current transformer input
1 A or 5 A secondary
Current measurement range
0.01–1.2 A on 1 A scale / 0.01–6 A on 5 A scale
Measurement method
RMS
Current overload withstand
50 A for 1 second
Relay outputs
2 × SPDT changeover contacts
Normally open contact rating
5 A at 250 V AC AC-1 / 5 A at 30 V DC
Normally closed contact rating
2 A at 250 V AC AC-1 / 2 A at 30 V DC
Digital inputs
4 isolated negative PNP inputs
Digital input voltage
12 V DC
Terminal type
Removable screw terminals
Maximum terminal torque
0.8 N·m
Conductor capacity
0.2–4 mm²
Mounting type
Modular DIN rail mounting
Housing width
6 modules
Protection rating
IP40 front / IP20 terminals
Dimensions (W × H × D)
108 × 105.4 × 63 mm
Weight
Approximately 470 g
Product status
Out of catalogue
Conformity
IEC/EN 61010-1, IEC/EN 61000-6-2 and IEC/EN 61000-6-4
HS Code
85364900
Frequently Asked Questions
What is the Lovato PMVF70 used for?
The PMVF70 monitors the connection between a local electricity generation system and the public distribution network. It controls an external interface device when abnormal grid or loss-of-mains conditions are detected.
Which UK grid requirements does the PMVF70 support?
The Lovato PMVF70 is certified for applications requiring compliance with the Energy Networks Association G59 and G99 engineering recommendations.
Can the PMVF70 monitor single-phase and three-phase systems?
Yes. The unit is suitable for single-phase and three-phase systems, including installations with or without a neutral conductor.
What loss-of-mains protection functions are included?
The PMVF70 provides rate of change of frequency and vector shift monitoring, alongside dual-threshold minimum and maximum voltage and frequency protection.
Is the Lovato PMVF70 still available?
Lovato Electric lists the PMVF70 as out of catalogue. Customers should contact LED Controls to confirm remaining availability or identify a suitable current interface protection system.
Trusted for UK Distributed Generation Protection
Lovato PMVF interface protection systems are used by renewable energy specialists, electrical engineers and panel builders to provide dependable grid supervision, loss-of-mains detection and disconnection control for distributed generation installations.
Manufacturer
Lovato Electric
Series
PMVF
Model
PMVF70
Product type
Interface protection system unit
System type
Single-phase and three-phase
Neutral configuration
With or without neutral
Network voltage
230 / 400 V AC
Applicable recommendations
ENA G59 / G99
Operating supply range
85–264 V AC / 93.5–300 V DC
Rated auxiliary supply
100–240 V AC / 110–250 V DC
Rated frequency
45–55 Hz
Maximum operational voltage
400 V AC line-to-line / 230 V AC line-to-neutral
Voltage measurement range
20–480 V AC line-to-line / 10–276 V AC line-to-neutral
Current transformer input
1 A or 5 A secondary
Current measurement range
0.01–1.2 A on 1 A scale / 0.01–6 A on 5 A scale
Measurement method
RMS
Current overload withstand
50 A for 1 second
Relay outputs
2 × SPDT changeover contacts
Normally open contact rating
5 A at 250 V AC AC-1 / 5 A at 30 V DC
Normally closed contact rating
2 A at 250 V AC AC-1 / 2 A at 30 V DC
Digital inputs
4 isolated negative PNP inputs
Digital input voltage
12 V DC
Terminal type
Removable screw terminals
Maximum terminal torque
0.8 N·m
Conductor capacity
0.2–4 mm²
Mounting type
Modular DIN rail mounting
Housing width
6 modules
Protection rating
IP40 front / IP20 terminals
Dimensions (W × H × D)
108 × 105.4 × 63 mm
Weight
Approximately 470 g
Product status
Out of catalogue
Conformity
IEC/EN 61010-1, IEC/EN 61000-6-2 and IEC/EN 61000-6-4
HS Code
85364900
No documents available for this product.
Delivery
We offer fast UK delivery on all stocked items. Orders placed before 3pm Monday to Friday are eligible for next-day delivery.
Standard delivery: 2–3 working days
Next-day delivery: available on in-stock items when ordered before 3pm
Express options available — contact us for details
Returns
If you need to return an item, please contact our sales team within 30 days of receipt. Items must be returned unused in their original packaging.
Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.
Priority sourcing and supply support
Flexible payment terms for qualifying organisations
Support for engineering, maintenance, and operations
500 +
Stock lines ready to ship
1,000 +
Same day dispatches
3500 +
Customers supported
28
Trusted Manfacturers
● frequently asked questions
Common questions about our products and support
At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.
What product ranges do you supply
We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products.
Can you help specify the correct part?
Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.
Do you have stock for urgent orders?
Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.
What are your delivery times and costs?
Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.
What about warranties, returns and faulty items?
Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.
LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.
2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...
2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...