ETE MV1000P2S2 Multi-Voltage Control Transformer 1000VA 20/0/380/420V to 10/0/220/240V

ETE MV1000P2S2 Multi-Voltage Control Transformer 1000VA 20/0/380/420V to 10/0/220/240V

ETE MV1000P2S2 is a 1000 VA single-phase multi-voltage control transformer with 20/0/380/420 V primary terminals, a 10/0/220/240 V tapped secondary requiring manufacturer-confirmed adjustment connections, Class E insulation, 4% voltage regulation and EPN 3 enclosure compatibility.

SKU: MV1000P2S2MPN: MV1000P2S2
Price
List Price £156.90 ex VAT
Your Price (ex VAT)
£156.90
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create a trade account to unlock exclusive pricing, special offers and more.

SUBTOTAL (EX VAT) £156.90
Trade pricing is personalised to your account

Manufacturer Lead Time

£156.90

Why Choose the ETE MV1000P2S2 1000 VA Multi-Voltage Control Transformer?

The ETE MV1000P2S2 is a high-capacity 1000 VA (1 kVA) single-phase multi-voltage control transformer designed for industrial electrical control panels, machinery and automation systems requiring flexible AC voltage transformation. Part of the ETE MV multi-voltage control transformer range, this model features 20/0/380/420 V primary terminals and 10/0/220/240 V secondary terminals, providing a tapped secondary output arrangement for compatible industrial control circuits.

The MV1000P2S2 combines a substantial 1 kVA apparent power rating with multiple primary and secondary winding connections. Its primary winding incorporates terminals marked 380 V and 420 V, while the secondary winding includes terminals marked 220 V and 240 V, together with a 10 V adjustment tap. This arrangement offers flexibility for industrial installations where the available AC supply must be transformed to an appropriate control voltage.

The secondary output is specified as a tapped output according to the manufacturer's datasheet. The exact relationship between the 10 V adjustment terminal and the other secondary terminals must be confirmed with ETE before installation. Similarly, the permitted primary connection combinations should be verified against the manufacturer's approved wiring information rather than inferred from the terminal markings alone.

Featuring Class E insulation and 4% voltage regulation, the MV1000P2S2 provides defined electrical characteristics for industrial transformer selection. Its dimensions of 150 × 125 × 145 mm and weight of 9.8 kg support integration into appropriately designed industrial electrical cabinets. The specified compatible enclosure reference is ETE EPN 3.

Listed in the ETE Stock Control Transformer Range, March 2026, the MV1000P2S2 is a practical choice for electrical panel builders, machinery manufacturers and maintenance engineers requiring a higher-capacity transformer with configurable AC control voltage connections.

Key Advantages

  • 1000 VA (1 kVA) rated capacity: Provides substantial apparent power for appropriately sized industrial AC control circuits.
  • Multi-voltage primary arrangement: Features 20/0/380/420 V primary terminals for flexible industrial supply connections.
  • Tapped secondary winding: Incorporates 10/0/220/240 V secondary terminals for manufacturer-defined output configurations.
  • Higher-voltage secondary connections: Includes terminals marked 220 V and 240 V for compatible AC control applications.
  • 10 V adjustment tap: Provides an additional secondary winding connection, with the correct terminal arrangement to be confirmed with ETE.
  • 4% voltage regulation: Provides a specified regulation characteristic for evaluating secondary voltage variation under load.
  • Class E insulation: Offers a defined insulation classification for industrial transformer applications.
  • Higher control power capacity: Suitable for systems containing multiple compatible AC control components.
  • Flexible control panel integration: Supports industrial machinery and automation circuits requiring transformer-derived AC power.
  • Defined dimensions: Measures 150 × 125 × 145 mm for installation planning.
  • Defined installation weight: Weighs 9.8 kg for mounting and mechanical support calculations.
  • Compatible enclosure reference: ETE EPN 3.
  • Versatile industrial applications: Suitable for compatible relays, contactors, motor control circuits and automation equipment.
  • Established product range: Listed in the ETE stock control transformer range, March 2026.

Key Features

  • Manufacturer: ETE.
  • Manufacturer part number: MV1000P2S2.
  • Product series: MV multi-voltage control transformers.
  • Transformer type: Single-phase industrial control transformer.
  • Rated apparent power: 1000 VA (1 kVA).
  • Primary terminal arrangement: 20/0/380/420 V.
  • Primary voltage terminal markings: 380 V and 420 V.
  • Additional primary terminal: 20 V.
  • Secondary terminal arrangement: 10/0/220/240 V.
  • Secondary voltage terminal markings: 220 V and 240 V.
  • Secondary adjustment tap: 10 V.
  • Output configuration: Tapped output according to ETE's approved connection information.
  • Connection precaution: Confirm the correct 10 V adjustment tap and associated terminal connections with ETE.
  • Calculated current equivalent at 220 V: Approximately 4.55 A, based on the total 1000 VA rating.
  • Calculated current equivalent at 240 V: Approximately 4.17 A, based on the total 1000 VA rating.
  • Insulation class: E.
  • Voltage regulation: 4%.
  • Length: 150 mm.
  • Width: 125 mm.
  • Height: 145 mm.
  • Weight: 9.8 kg.
  • Compatible enclosure reference: EPN 3.

Reliable 1 kVA Tapped AC Control Power for Industrial Electrical Systems

The ETE MV1000P2S2 provides a high-capacity solution for industrial electrical installations requiring a transformer with multiple primary and secondary connection options. Its 20/0/380/420 V primary winding and 10/0/220/240 V secondary winding make it suitable for applications where an industrial AC supply must be transformed to a compatible higher-voltage AC control circuit.

The primary winding incorporates terminals marked 380 V and 420 V, together with an additional 20 V terminal. These markings identify available winding connections but do not independently establish every permissible supply voltage combination. The correct primary terminal arrangement should be verified against ETE's approved connection diagram before the transformer is energised.

The secondary winding features terminals marked 220 V and 240 V, together with a 10 V adjustment tap. The manufacturer's specification describes the output as a tapped output, with the exact terminal arrangement to be determined from the approved datasheet. The 10 V terminal should not be assumed to provide an independent 10 V supply, and the relationship between the secondary connections must be confirmed with ETE.

At the total rated apparent power of 1000 VA, the calculated current equivalents are approximately 4.55 A at 220 V and 4.17 A at 240 V. These figures are derived by dividing the transformer rating by the nominal secondary voltage. They should not be interpreted as independently verified current ratings for every tapped output arrangement. The applicable winding and tap loading limits should be checked before finalising the connected load.

The specified 4% voltage regulation is relevant when selecting a transformer for control circuits containing electromagnetic loads. Contactors, relays and solenoids may draw greater apparent power during energisation than during normal operation. Electrical designers should therefore assess the total steady-state load, simultaneous switching requirements and acceptable voltage range of connected equipment.

With a rated capacity of 1 kVA, the MV1000P2S2 is particularly relevant to industrial control systems containing multiple compatible AC devices. The transformer should be selected according to the aggregate apparent power requirements of the installation, while allowing for equipment starting demands and the manufacturer's winding-specific limits.

The MV1000P2S2 features Class E insulation, dimensions of 150 × 125 × 145 mm and a weight of 9.8 kg. These characteristics should be considered when planning mounting arrangements, mechanical support and enclosure space. The specified compatible enclosure reference is ETE EPN 3.

The transformer provides AC voltage transformation rather than regulated DC output. Equipment requiring DC control voltage will need appropriate additional conversion components. Installation should account for correct primary and secondary terminal selection, suitable circuit protection, conductor sizing, secure mounting, ventilation and protective earthing where applicable.

Typical Applications

  • Industrial electrical control panels requiring tapped AC transformer outputs.
  • Machinery control systems using compatible industrial primary voltage connections.
  • OEM machinery and electrical panel manufacturing.
  • Compatible 220 V AC and 240 V AC control circuits.
  • Higher-capacity contactor and electromagnetic relay control systems.
  • Motor starter panels and machine control equipment.
  • Industrial signalling and indication circuits.
  • Automation equipment requiring transformer-derived AC control power.
  • Packaging machinery and conveyor control systems.
  • Industrial process control installations.
  • Electrical maintenance and refurbishment projects.
  • Replacement of compatible 1000 VA multi-voltage control transformers.

Technical Specifications

Tick the specs you need, then view products that match.

Brand ETE
Rated Power (VA) 1000 VA
Primary Voltage 20/0/380/420V
Secondary Voltage 10/0/220/240V
Phase Single Phase
Manufacturer part number MV1000P2S2
Product family MV Multi-Voltage Control Transformers
Product category Industrial Control Transformers
Transformer configuration Multi-tapped primary and secondary windings
Number of phases Single-phase
Rated apparent power 1000 VA
Rated apparent power in kVA 1 kVA
Primary terminal arrangement 20/0/380/420 V
Primary voltage terminal markings 380 V and 420 V
Additional primary terminal 20 V
Primary connection requirement Verify permitted terminal combinations with ETE.
Secondary terminal arrangement 10/0/220/240 V
Secondary voltage terminal markings 220 V and 240 V
Secondary adjustment tap 10 V
Secondary output connection Tapped output according to the manufacturer's datasheet
Adjustment tap connection note Confirm the correct 10 V adjustment tap and associated terminal connections with ETE.
Calculated apparent-power current equivalent at 220 V secondary Approximately 4.55 A
Calculated apparent-power current equivalent at 240 V secondary Approximately 4.17 A
Calculated apparent-power current equivalent at 380 V primary Approximately 2.63 A
Calculated apparent-power current equivalent at 420 V primary Approximately 2.38 A
Insulation class E
Voltage regulation 4%
Length 150 mm
Width 125 mm
Height 145 mm
Overall dimensions (L × W × H) 150 × 125 × 145 mm
Weight 9.8 kg
Compatible enclosure reference EPN 3
Typical installation Industrial electrical control panels and machinery cabinets
Catalogue reference ETE Stock Control Transformer Range, March 2026

Frequently Asked Questions

What is the ETE MV1000P2S2 used for?

The ETE MV1000P2S2 is a 1000 VA single-phase multi-voltage control transformer designed for industrial AC control circuits requiring a tapped primary and secondary winding arrangement.

What is the rated apparent power of the MV1000P2S2?

The transformer has a rated apparent power of 1000 VA, equivalent to 1 kVA. Connected equipment must remain within the applicable transformer and winding ratings.

What are the primary terminals on the MV1000P2S2?

The primary terminal markings are 20/0/380/420 V. The correct terminal combinations should be verified against ETE's approved connection information.

What secondary terminals does the MV1000P2S2 have?

The secondary winding has terminals marked 10/0/220/240 V. The output is configured using the manufacturer's specified tapped connection arrangement.

Does the MV1000P2S2 provide 220 V or 240 V AC output?

The secondary includes terminals marked 220 V and 240 V. The exact nominal output available for a particular primary connection must be confirmed from ETE's wiring information.

What is the purpose of the 10 V adjustment tap?

The 10 V adjustment terminal provides an additional secondary winding connection. Its precise function and permitted use must be confirmed with ETE before installation.

Can the 10 V adjustment tap be used as an independent 10 V output?

This should not be assumed. The 10 V terminal forms part of the transformer's tapped winding arrangement, and its permitted connection method must be verified with ETE.

Can the MV1000P2S2 be connected to a 400 V AC supply?

The transformer has primary terminals marked 380 V and 420 V, together with an additional 20 V terminal. The correct connection arrangement for a nominal 400 V AC supply must be confirmed with ETE rather than inferred from terminal markings alone.

What is the calculated secondary current at 220 V?

At 1000 VA and 220 V, the calculated current equivalent is approximately 4.55 A, assuming the total transformer rating applies to the approved output configuration.

What is the calculated secondary current at 240 V?

At 1000 VA and 240 V, the calculated current equivalent is approximately 4.17 A, assuming the total transformer rating applies to the approved output configuration.

What are the calculated primary current equivalents?

Dividing the rated apparent power by the marked primary voltages gives approximately 2.63 A at 380 V and 2.38 A at 420 V. These are mathematical apparent-power equivalents rather than independently verified operating input currents.

Does the MV1000P2S2 provide AC or DC output?

The MV1000P2S2 provides AC output. It does not incorporate a rectifier or regulated DC power supply.

What insulation class and voltage regulation does the MV1000P2S2 have?

The transformer has Class E insulation and a specified 4% voltage regulation.

What are the dimensions and weight of the ETE MV1000P2S2?

The transformer measures 150 mm long × 125 mm wide × 145 mm high and weighs 9.8 kg.

Which enclosure is compatible with the MV1000P2S2?

The specified compatible enclosure reference is ETE EPN 3. Final enclosure selection should account for the installation environment, mounting requirements and ventilation.

Can the MV1000P2S2 be used in industrial control panels?

Yes. Its 1000 VA rating, multi-tapped windings and industrial construction make it suitable for appropriately designed control panels using compatible AC equipment.

Why is voltage regulation important when selecting this transformer?

The specified 4% voltage regulation describes secondary voltage variation under changing load conditions. Connected equipment should have suitable voltage tolerances for the intended application.

Where can the correct terminal connection diagram be confirmed?

The correct primary and secondary wiring arrangements should be obtained from ETE or its approved technical documentation, particularly when using the 10 V adjustment tap.

A Practical Choice for Industrial Control Panel Builders

The ETE MV1000P2S2 combines a substantial 1000 VA rating with flexible primary connections and a tapped secondary winding incorporating 220 V and 240 V terminals. Its Class E insulation, 4% voltage regulation and EPN 3 enclosure compatibility make it a practical component for industrial electrical panel builders, machinery manufacturers and maintenance engineers requiring higher-capacity configurable AC control power.

● Service Agreements

Credit Accounts

Our service agreements are built to support long term procurement relationships. By working closely with engineering teams and procurement departments, we help streamline purchasing processes while ensuring consistent access to critical components and sourcing support when it matters most.

 Priority sourcing and supply support

 Flexible payment terms for qualifying organisations

 Support for engineering, maintenance, and operations

500 +

Stock lines ready to ship

1,000 +

Same day dispatches

3500 +

Customers supported

28 

Trusted Manfacturers

● frequently asked questions

Common questions about our products and support

 

At Led Controls Ltd we help engineers source the right automation and control gear with confidence. below are quick answers to what we are asked most often.

What product ranges do you supply

We supply all leading manfacturers in our industry. we offer next day delivery on most poplour products. 

Can you help specify the correct part?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Do you have stock for urgent orders?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What are your delivery times and costs?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

What about warranties, returns and faulty items?

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

● latest blog

Discover  our latest insights and
expert advice

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

From a Simple Idea to Small Business of the Year: The LED Controls Story So Far…

LED Controls is a specialist distributor of factory automation and industrial controls, supplying OEMs, machine builders, panel builders and end users throughout the UK and worldwide. As a trusted UK distributor for many of the world’s leading automation manufacturers, we provide industrial control products, technical expertise and bespoke automation solutions backed by outstanding customer service.

LED Controls: Danfoss Drives Authorised Partner

LED Controls: Danfoss Drives Authorised Partner

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...

LED Controls: Your Complete Control Panel Solution

LED Controls: Your Complete Control Panel Solution

2025 has been a big year for LED Controls, and our blog has expanded accordingly. We've covered a wide range of topics across industrial control and factory automation this year. From core technology explainers and new product releases to panel building best practice...